The potential of accidental loads such as explosions and impacts cannot be overlooked given the widespread use of precast concrete (PC) buildings. However, research on the impact resistance of reinforced concrete precast beams is limited. In order to explore the dynamic behavior of PC beams connected by grouted sleeves under impact loads, this work developed a numerical model based on the finite element program LS-DYNA. First, the experimental process was described in detail, and the numerical model was evaluated and calibrated according to the experimental data. Then, parameters such as impact location, concrete strength of precast section and stirrup rate of cast-in-place area were studied. Finally, a simpler model based on equal high-frequency impulse impact force was suggested, and the viability of a single-degree-of-freedom model theory was proved for the dynamic analysis of PC simply supported beams subjected to impact loading. According to the findings, the interface of precast concrete and cast-in-place concrete is the weak point of the PC beam, which is prone to shear damage under impact loads. Second, when the middle of the cast-in-place part of the PC beam is impacted, wide cracks from the bottom to the top are quite likely to form. As a result, the most disadvantageous impact position for PC beams is in the middle of the cast-in-place portion. Although increasing the concrete strength of the precast section can reduce crack formation, it has minimal influence on the interface’s shear resistance. Furthermore, increasing the stirrup rate in the post-cast portion can increase the overall shear resistance of the PC beams.
The strong interaction between impact loading and joints can induce slip instability in jointed rock masses, posing a serious threat to construction safety and long-term stability in rock engineering. To investigate the dynamic slip characteristics of rock-like specimens containing an artificial persistent joint under impact loading, cement mortar rock like specimens with joint dip angles of 50°, 60°, and 70° were prepared. Impact tests were conducted using an SHPB system combined with high-speed imaging and DIC. The results show that the presence of joints significantly deteriorates the dynamic load-bearing capacity of the rock mass and reduces stress-wave transmission. As the joint dip angle increases from 50° to 70°, the shear stress component acting on the joint decreases, while the normal constraint increases. As a result, joint slip is suppressed, and both slip displacement and slip velocity decrease. Joint slip can induce secondary cracks to propagate into the rock matrix, but failure becomes more localized along the joint as the dip angle increases. Increasing impact loading intensity significantly increases the dynamic strength of jointed rock masses, intensifies joint slip, and induces more severe secondary damage. Energy analysis shows that joints change the energy dissipation mechanism. The input energy is mainly dissipated through joint compression deformation, shear slip, and induced secondary damage. The results provide a reference for stability evaluation and dynamic disaster prevention in jointed rock masses under impact disturbance.