Hydrodynamic cavitation (HC) is a phase change phenomenon, where energy release in a fluid occurs upon the collapse of bubbles, which form due to the low local pressures.
Soft lithography with microfabricated molds is a widely used manufacturing method. Recent advancements in 3D printing technologies have enabled microscale feature resolution, providing a promising alternative for mold fabrication. It is well established that the curing of PDMS is influenced by parameters such as temperature, time, and curing agent ratio. This study was conducted to address inconsistencies in PDMS curing observed when using different 3D-printed mold materials during the development of a Lab-on-a-Chip (LoC) system, which is typically employed for investigating the effect of hydrodynamic cavitation on blood clot disintegration. To evaluate the impact of mold material on PDMS curing behavior, PDMS was cast into molds made from polylactic acid (PLA), polyethylene terephthalate (PET), resin, and aluminum, and cured at controlled temperatures (55, 65, and 75 °C) for various durations (2, 6, and 12 h). Curing performance was assessed using Soxhlet extraction, Young’s modulus calculations derived from Atomic Force Microscopy (AFM), and complementary characterization methods. The results indicate that the mold material significantly affects PDMS curing kinetics due to differences in thermal conductivity and surface interactions. Notably, at 65 °C, PDMS cured in aluminum molds had a higher Young’s modulus (~1.84 MPa) compared to PLA (~1.23 MPa) and PET (~1.17 MPa), demonstrating that the mold material can be leveraged to tailor the mechanical properties. These effects were especially pronounced at lower curing temperatures, where PLA and PET molds offered better control over PDMS elasticity, making them suitable for applications requiring flexible LoC devices. Based on these findings, 3D-printed PLA molds show strong potential for PDMS-based microdevice fabrication.
Glioblastoma multiforme is one of the most aggressive malignant primary brain tumors. To design effective treatment strategies, we need to better understand the behavior of glioma cells while maintaining their genetic and phenotypic stability. Here, we investigated the deformation and migration profile of U87 Glioma cells under the influence of dielectrophoretic forces. We fabricated a gold microelectrode array within a microfluidic channel and applied sinusoidal wave AC potential at 3 Vpp, ranging from 30 kHz to 10 MHz frequencies, to generate DEP forces. We followed the dielectrophoretic movement and deformation changes of 100 glioma cells at each frequency. We observed that the mean dielectrophoretic displacements of glioma cells were significantly different at varying frequencies with the maximum and minimum traveling distances of 13.22 µm and 1.37 µm, respectively. The dielectrophoretic deformation indexes of U87 glioma cells altered between 0.027–0.040. It was 0.036 in the absence of dielectrophoretic forces. This approach presents a rapid, robust, and sensitive characterization method for quantifying membrane deformation of glioma cells to determine the state of the cells or efficacy of administrated drugs.
This study evaluates the thrombolytic potential of microscale hydrodynamic cavitation (HC) on a clot-on-a-chip platform and compares its performance with acoustic cavitation, highlighting HC's potential for safer, targeted, drug-free thrombolysis.