The concepts of “optimal posture (OP)” and “harmful posture (HP)” are commonly used, and specific spinal postures can contribute to back pain. However, quantitative descriptions of optimal and harmful standing (StP) and sitting (SP) postures are currently lacking, particularly for different body mass indices (BMIs). Therefore, this study aimed to identify and quantify the OPs and HPs of StP and SP at different BMIs and investigate the attitudes and beliefs of rehabilitation practitioners toward OPs and HPs. Overall, 552 rehabilitation practitioners were recruited to participate in a questionnaire survey to select the optimal position from seven sitting and five standing postures for each BMI healthy volunteer. The segmental relationships of each posture were qualified using the Vicon software. For normal BMI, the physiotherapists chose two SPs (48.19% and 49.64%) and one StP (80.42%) as the OP. One sitting SP (83.7%) and two standing StPs (43.48% and 48.19%) were selected as optimal for obese BMI. All the most commonly selected OPs had an upright lordotic posture, while the postures with slouched spinal curves or forward head postures were almost all selected as HP. Additionally, 96.74% of participants considered education about optimal SP and StP to be “quite” or “very” important. The OP of the StP and SP postures was mostly based on the vertical alignment of gravity lines and sagittal balance. For obese people, the rehabilitation practitioners’ observations may be erroneous, and further physical examination is necessary. Rehabilitation practitioners generally believe that postural education is essential in clinical practice.
Purpose: To systematically review and meta-analyze the literature evaluating the biomechanical and clinical efficacies of foot orthoses for medial tibiofemoral osteoarthritis (TF-OA). Methods: Through using the PubMed and Scopus databases, the scientific manuscripts were identified, screened, and classified. Quality of the included articles was evaluated. Where possible, meta-analyses were performed on the peak knee adduction moment (KAM), knee adduction angular impulse (KAAI), pain, function scores, and gait speed. Effect sizes were calculated as standardized mean differences with 95% confidence intervals. Pooled standard mean differences (SMDs) were calculated using a fixed-effects model; when substantial heterogeneity was detected ( I2 ≥ 50%), a random-effects model was applied. Results: Ninety-two original research articles were included, and categorized into Lateral Wedge Insoles (LWI) , Variable Stiffness Shoes (VSS) , Hybrid (LWI + VSS) , AposTherapy , Ankle-Foot Orthoses (AFOs) , and Others groups. Only LWIs with moderate inclinations (5–10°) showed significant small-to-moderate reductions in the 1 st peak KAM during both immediate responses and mid-long-term follow-ups, significant moderate-to-large mid-long-term improvements in knee pain, function, and gait speed. LWIs with low inclinations (≤ 5°) showed significant small immediate reductions in the 2 nd peak KAM and KAAI and significant small mid-long-term improvements in knee pain and function. AFOs and AposTherapy shoes demonstrated significant large clinical benefits after mid-long-term interventions. VSSs exhibited immediate biomechanical efficacy in reducing the 1 st peak KAM. Conclusion: LWIs with moderate inclinations may be most effective for medial TF-OA. More studies are needed to clarify the effects of AposTherapy shoes, AFOs, and VSSs. Adaptation training with newly prescribed orthoses may enhance biomechanical and clinical outcomes. PROSPERO registration number: CRD420251240304.
Objective: The traditional femoral stem is unsuitable for patients with severe proximal femoral bone defects or deformities. However, 3D‐printed customized designs offer improved proximal femoral canal contact and enhance the initial stability of the femoral prosthesis. Therefore, this study aims to compare the anatomical parameters, contact parameters, and performance of the 3D‐printed customized femoral short (CFS) stem with those of the traditional femoral stem following total hip arthroplasty (THA).Methods: An in vitro study simulating THA was performed using artificial femur models, with a 3D‐printed CFS stem as the experimental group and a Trilock stem as the control group. Anatomical parameters, fitness, filling, micro‐motion, and strain distribution were evaluated using artificial femoral models. Micro‐motion and strain were recorded under different simulated bodyweight loading using a 3D digital image correlation measurement system.Results: The neck‐shaft angles (NSA) and coronal femoral horizontal offset (CFHO) of the 3D‐printed CFS stem (NSA: 125.22°, CFHO: 41.03 mm) were closer to those of the intact femur (NSA: 127.37°, CFHO: 43.27 mm) compare with the Trilock stem (NSA: 132.61°, CFHO: 32.98 mm). In addition, the 3D‐printed CFS stem showed improved fitness at cross‐sections (The top of the lesser trochanter: 6.31%, the middle of the lesser trochanter: 23.42%, the bottom of the lesser trochanter: 26.61%) and reduced micro‐motion under different simulated bodyweight loads (1000: 0.043, 1375: 0.056, 2060 N: 0.061 mm).Conclusions: The 3D‐printed CFS stem provides improved restoration of anatomical parameters, enhanced fitness, and superior biomechanical performance compared with the Trilock stem.
22 July 2025 in Journal of Back and Musculoskeletal Rehabilitation
Background: The thoracic spinal range of motion (ROM) is a commonly used in pathological and functional assessment. Baseline bubble inclinometers are one of the most frequently employed thoracic ROM measurement methods. However, there is currently no consensus on the accuracy and standardized procedure of their utilization. Objective: The purpose of this study is to validate the accuracy of baseline bubble inclinometers in measuring the sagittal thoracic spinal ROM and to propose the standard guideline for their utilization. Method: 28 participants were recruited for this study. The maximum thoracic spinal ROM during flexion and extension was measured using inclinometers, with the optoelectronic motion capture system (Vicon) serving as the control group. Result: The thoracic spinal ROM during flexion was 14.5 ± 10.5°; during extension was 19.0 ± 9.2°, and the total ROM was 33.5 ± 14.0°. The inclinometers showed moderate to high correlations with the Vicon results, particularly in measuring flexion ROM, which exhibited the highest effectiveness (r = 0.84∼0.89). The accuracy of the inclinometers was enhanced by ensuring a cervical nodding and fixation position. Additionally, it was observed that females were more suitable candidates for thoracic spinal ROM measurement using inclinometers, as they exhibited higher correlations with the Vicon results. Conclusion: This study successfully validated the accuracy of the inclinometer as a convenient thoracic spinal ROM measurement method, that can save significant time for physiotherapists in clinical settings. The measurements obtained in this study may serve as a preliminary reference for the thoracic spinal ROM in healthy individuals and standardized protocols for using the baseline bubble inclinometer.