Seyyed Hamed Hosseini Nasab

Dr. Seyyed Hamed Hosseini Nasab

Laboratory for Movement Biomechanics, ETH Zurich, Switzerland
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2017 in Journal of Biomechanics
Verified
Journal Article
Open access
William R. TaylorWilliam R. Taylor
William R. Taylor
PSPascal Schütz
Pascal Schütz
GBGeorg Bergmann
Georg Bergmann
RLRenate List
Renate List
BPBarbara Postolka
Barbara Postolka
IKInes Kutzner
Ines Kutzner
Combined knowledge of the functional kinematics and kinetics of the human body is critical for understanding a wide range of biomechanical processes including musculoskeletal adaptation, injury mechanics, and orthopaedic treatment outcome, but also for validation of musculoskeletal models. Until now, however, no datasets that include internal loading conditions (kinetics), synchronized with advanced kinematic analyses in multiple subjects have been available. Our goal was to provide such datasets and thereby foster a new understanding of how in vivo knee joint movement and contact forces are interlinked - and thereby impact biomechanical interpretation of any new knee replacement design. In this collaborative study, we have created unique kinematic and kinetic datasets of the lower limb musculoskeletal system for worldwide dissemination by assessing a unique cohort of 6 subjects with instrumented knee implants (Charité - Universitätsmedizin Berlin) synchronized with a moving fluoroscope (ETH Zürich) and other measurement techniques (including whole body kinematics, ground reaction forces, video data, and electromyography data) for multiple complete cycles of 5 activities of daily living. Maximal tibio-femoral joint contact forces during walking (mean peak 2.74 BW), sit-to-stand (2.73 BW), stand-to-sit (2.57 BW), squats (2.64 BW), stair descent (3.38 BW), and ramp descent (3.39 BW) were observed. Internal rotation of the tibia ranged from 3° external to 9.3° internal. The greatest range of anterio-posterior translation was measured during stair descent (medial 9.3 ± 1.0 mm, lateral 7.5 ± 1.6 mm), and the lowest during stand-to-sit (medial 4.5 ± 1.1 mm, lateral 3.7 ± 1.4 mm). The complete and comprehensive datasets will soon be made available online for public use in biomechanical and orthopaedic research and development.

15 May 2019 in The American Journal of Sports Medicine
Verified
Journal Article
Open access
PDF file
CHChristian Huber
Christian Huber
QZQiang Zhang
Qiang Zhang
William R. TaylorWilliam R. Taylor
William R. Taylor
AAAndrew A. Amis
Andrew A. Amis
CSColin Smith
Colin Smith
Seyyed Hamed Hosseini NasabSeyyed Hamed Hosseini Nasab
Seyyed Hamed Hosseini Nasab
Background: As the main passive structure preventing patellar lateral subluxation, accurate knowledge of the anatomy, material properties, and functional behavior of the medial patellofemoral ligament (MPFL) is critical for improving its reconstruction. Purpose: To provide a state-of-the-art understanding of the properties and function of the MPFL by undertaking a systematic review and statistical analysis of the literature. Study Design: Systematic review. Methods: On June 26, 2018, data for this systematic review were obtained by searching PubMed and Scopus. Articles containing numerical information regarding the anatomy, mechanical properties, and/or functional behavior of the MPFL that met the inclusion criteria were reviewed, recorded, and statistically evaluated. Results: A total of 55 articles met the inclusion criteria for this review. The MPFL presented as a fanlike structure spanning from the medial femoral epicondyle to the medial border of the patella. The reported data indicated ultimate failure loads from 72 N to 208 N, ultimate failure elongation from 8.4 mm to 26 mm, and stiffness values from 8.0 N/mm to 42.5 N/mm. In both cadaveric and in vivo studies, the average elongation pattern demonstrated close to isometric behavior of the ligament in the first 50° to 60° of knee flexion, followed by progressive shortening into deep flexion. Kinematic data suggested clear lateralization of the patella in the MPFL-deficient knee during early knee flexion under simulated muscle forces. Conclusion: A lack of knowledge regarding the morphology and attachment sites of the MPFL remains. The reported mechanical properties also lack consistency, thus requiring further investigations. However, the results regarding patellar tracking confirm that the lack of an MPFL leads to lateralization of the patella, followed by delayed engagement of the trochlear groove, plausibly leading to an increased risk of patellar dislocations. The observed isometric behavior up to 60° of knee flexion plausibly suggests that reconstruction of the ligament can occur at flexion angles below 60°, including the 30° and 60° range as recommended in previous studies.

30 January 2020 in Annals of Biomedical Engineering
Verified
Journal Article
Open access
PDF file
ZNZohreh Imani Nejad
Zohreh Imani Nejad
KKKhalil Khalili
Khalil Khalili
Seyyed Hamed Hosseini NasabSeyyed Hamed Hosseini Nasab
Seyyed Hamed Hosseini Nasab
PSPascal Schütz
Pascal Schütz
PDPhilipp Damm
Philipp Damm
CSColin R Smith
Colin R Smith
Musculoskeletal models enable non-invasive estimation of knee contact forces (KCFs) during functional movements. However, the redundant nature of the musculoskeletal system and uncertainty in model parameters necessitates that model predictions are critically evaluated. This study compared KCF and muscle activation patterns predicted using a scaled generic model and OpenSim static optimization tool against in vivo measurements from six patients in the CAMS-knee datasets during level walking and squatting. Generally, the total KCFs were under-predicted (RMS: 47.55%BW, R2: 0.92) throughout the gait cycle, but substiantially over-predicted (RMS: 105.7%BW, R2: 0.81) during squatting. To understand the underlying etiology of the errors, muscle activations were compared to electromyography (EMG) signals, and showed good agreement during level walking. For squatting, however, the muscle activations showed large descrepancies especially for the biceps femoris long head. Errors in the predicted KCF and muscle activation patterns were greatest during deep squat. Hence suggesting that the errors mainly originate from muscle represented at the hip and an associated muscle co-contraction at the knee. Furthermore, there were substaintial differences in the ranking of subjects and activities based on peak KCFs in the simulations versus measurements. Thus, future simulation study designs must account for subject-specific uncertainties in musculoskeletal predictions.

6 October 2020 in Annals of Biomedical Engineering
Verified
Journal Article
Open access
PDF file
QZQiang Zhang
Qiang Zhang
NANaomi C. Adam
Naomi C. Adam
Seyyed Hamed Hosseini NasabSeyyed Hamed Hosseini Nasab
Seyyed Hamed Hosseini Nasab
William R. TaylorWilliam R. Taylor
William R. Taylor
CSColin R. Smith
Colin R. Smith
The critical clinical and scientific insights achieved through knowledge ofin vivomusculoskeletal soft tissue strains has motivated the development of relevant measurement techniques. This review provides a comprehensive summary of the key findings, limitations, and clinical impacts of these techniques to quantify musculoskeletal soft tissue strains during dynamic movements. Current technologies generally leverage three techniques to quantifyin vivostrain patterns, including implantable strain sensors, virtual fibre elongation, and ultrasound. (1) Implantable strain sensors enable direct measurements of tissue strains with high accuracy and minimal artefact, but are highly invasive and current designs are not clinically viable. (2) The virtual fibre elongation method tracks the relative displacement of tissue attachments to measure strains in both deep and superficial tissues. However, the associated imaging techniques often require exposure to radiation, limit the activities that can be performed, and only quantify bone-to-bone tissue strains. (3) Ultrasound methods enable safe and non-invasive imaging of soft tissue deformation. However, ultrasound can only image superficial tissues, and measurements are confounded by out-of-plane tissue motion. Finally, allin vivostrain measurement methods are limited in their ability to establish the slack length of musculoskeletal soft tissue structures. Despite the many challenges and limitations of these measurement techniques, knowledge ofin vivosoft tissue strain has led to improved clinical treatments for many musculoskeletal pathologies including anterior cruciate ligament reconstruction, Achilles tendon repair, and total knee replacement. This review provides a comprehensive understanding of these measurement techniques and identifies the key features ofin vivostrain measurement that can facilitate innovative personalized sports medicine treatment.

23 November 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Seyyed Hamed Hosseini NasabSeyyed Hamed Hosseini Nasab
Seyyed Hamed Hosseini Nasab
RLRenate List
Renate List
KOKatja Oberhofer
Katja Oberhofer
SFSandro F. Fucentese
Sandro F. Fucentese
JSJess G. Snedeker
Jess G. Snedeker
William R. TaylorWilliam R. Taylor
William R. Taylor
The posterior cruciate ligament (PCL) is the strongest ligament of the knee, serving as one of the major passive stabilizers of the tibio-femoral joint. However, despite a number of experimental and modelling approaches to understand the kinematics and kinetics of the ligament, the normal loading conditions of the PCL and its functional bundles are still controversially discussed. This study aimed to generate science-based evidence for understanding the functional loading of the PCL, including the anterolateral and posteromedial bundles, in the healthy knee joint through systematic review and statistical analysis of the literature. MEDLINE, EMBASE and CENTRAL Databases were searched for articles containing any numerical strain or force data on the healthy PCL and its functional bundles. Studied activities were as follows: passive flexion, flexion under 100N and 134N posterior tibial load, walking, stair ascent and descent, body-weight squatting and forward lunge. Statistical analysis was performed on the reported load data, which was weighted according to the number of knees tested to extract average strain and force trends of the PCL and identify deviations from the norms. From the 3577 articles retrieved by the initial electronic search, only 66 met all inclusion criteria. The results obtained by aggregating data reported in the eligible studies indicate that the loading patterns of the PCL vary with activity type, knee flexion angle, but importantly also the technique used for assessment. Moreover, different fibres of the PCL exhibit different strain patterns during knee flexion, with higher strain magnitudes reported in the anterolateral bundle. While during passive flexion the posteromedial bundle is either lax or very slightly elongated, it experiences higher strain levels during forward lunge and has a synergetic relationship with the anterolateral bundle. The strain patterns obtained for virtual fibres that connect the origin and insertion of the bundles in a straight line show similar trends to those of the real bundles but with different magnitudes. This review represents what is now the best available understanding of the biomechanics of the PCL, and may help to improve programs for injury prevention, diagnosis methods as well as reconstruction and rehabilitation techniques.

12 November 2019 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
Seyyed Hamed Hosseini NasabSeyyed Hamed Hosseini Nasab
Seyyed Hamed Hosseini Nasab
CSColin R. Smith
Colin R. Smith
PSPascal Schütz
Pascal Schütz
BPBarbara Postolka
Barbara Postolka
RLRenate List
Renate List
William R. TaylorWilliam R. Taylor
William R. Taylor
The primary aim of this study was to assess the effects of total knee arthroplasty (TKA) implant design on collateral ligament elongation patterns that occur during level walking, downhill walking, and stair descent. Using a moving fluoroscope, tibiofemoral kinematics were captured in three groups of patients with different TKA implant designs, including posterior stabilized, medial stabilized, and ultra-congruent. The 3D in vivo joint kinematics were then fed into multibody models of the replaced knees and elongation patterns of virtual bundles connecting origin and insertion points of the medial and lateral collateral ligaments (MCL and LCL) were determined throughout complete cycles of all activities. Regardless of the implant design and activity type, non-isometric behavior of the collateral ligaments was observed. The LCL shortened with increasing knee flexion, while the MCL elongation demonstrated regional variability, ranging from lengthening of the anterior bundle to slackening of the posterior bundle. The implant component design did not demonstrate statistically significant effects on the collateral elongation patterns and this was consistent between the studied activities. This study revealed that post-TKA collateral ligament elongation is primarily determined by the knee flexion angle. The different anterior translation and internal rotation that were induced by three distinctive implant designs had minimal impact on the length change patterns of the collateral ligaments.