Rodolfo Gabriel Figueroa

Dr. Rodolfo Gabriel Figueroa

orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 May 2016 in Radiation Measurements
Verified
Journal Article
Open access
JVJ. Vedelago
J. Vedelago
DOD. Chacón Obando
D. Chacón Obando
FMF. Malano
F. Malano
RCR. Conejeros
R. Conejeros
RFRodolfo Gabriel Figueroa
Rodolfo Gabriel Figueroa
MVMauro Valente
Mauro Valente
Complexity in modern radiotherapy treatments demands advanced dosimetry systems for quality control. These systems must have several characteristics, such as high spatial resolution, tissue equivalence, three-dimensional resolution, and dose-integrating capabilities. In this scenario, gel dosimetry has proved to be a very promising option for quality assurance. In this study, the feasibility of Fricke and polymer gel dosimeters suitably shaped in form of thin layers and optically analyzed by visible light transmission imaging has been investigated for quality assurance in external radiotherapy. Dosimeter irradiation was carried out with a 6-MV photon beam (CLINAC 600C). The analysis of the irradiated dosimeters was done using two-dimensional optical transmission images. These dosimeters were compared with a treatment plan system using Monte Carlo simulations as a reference by means of a gamma test with parameters of 1 mm and 2%. Results show very good agreement between the different dosimetric systems: in the worst-case scenario, 98% of the analyzed points meet the test quality requirements. Therefore, gel dosimetry may be considered as a potential tool for the validation of other dosimetric systems.

1 August 2013 in Spectrochimica Acta Part B: Atomic Spectroscopy
Verified
Journal Article
Closed access
ASAna Luísa M. Silva
Ana Luísa M. Silva
RFRodolfo Gabriel Figueroa
Rodolfo Gabriel Figueroa
AJA. Jaramillo
A. Jaramillo
MCMaria Leonor Carvalho
Maria Leonor Carvalho
JVJoão Filipe Calapez De Albuquerque Veloso
João Filipe Calapez De Albuquerque Veloso

11 December 2013 in X-Ray Spectrometry
Verified
Journal Article
Closed access
PDF file
RFRodolfo Gabriel Figueroa
Rodolfo Gabriel Figueroa
ELE. Lozano
E. Lozano
FBF. Belmar
F. Belmar
DAD. Alcaman
D. Alcaman
ABA. von Bohlen
A. von Bohlen
JVJoão Filipe Calapez De Albuquerque Veloso
João Filipe Calapez De Albuquerque Veloso

28 August 2015 in Radiation Physics and Chemistry
Verified
Journal Article
Closed access
RFRodolfo Gabriel Figueroa
Rodolfo Gabriel Figueroa
MSM. Santibañez
M. Santibañez
FMF. Malano
F. Malano
MVMauro Valente
Mauro Valente

8 July 2016 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
MVMauro Vaiente
Mauro Vaiente
WMWladimir Molina
Wladimir Molina
LSLila Carrizales Silva
Lila Carrizales Silva
RFRodolfo Gabriel Figueroa
Rodolfo Gabriel Figueroa
FMFrancisco Malano
Francisco Malano
JVJosé Vedelago
José Vedelago
Fricke solution has a wide range of applications as radiation detector and dosimetry. It is particularly appreciated in terms of relevant comparative advantages, like tissue‐equivalence when prepared in aqueous media like gel matrix, continuous mapping capability, independence of dose rate and incident direction, as well as linear dose response. This work presents the development and characterization of an improved Fricke gel system, based on modified chemical compositions, making possible its application in clinical radiology due to its improved sensitivity. Properties of standard Fricke gel dosimeter for high‐dose levels are used as a starting point, and suitable chemical modifications are introduced and carefully investigated in order to attain high resolution for low‐dose ranges, like those corresponding to radiology interventions. The developed Fricke gel radiation dosimeter system achieves the expected typical dose‐dependency, showing linear response in the dose range from 20 up to 4000 mGy. Systematic investigations including several chemical compositions are carried out in order to obtain an adequate dosimeter response for low‐dose levels. A suitable composition from among those studied is selected as a good candidate for low‐dose‐level radiation dosimetry consisting of a modified Fricke solution fixed to a gel matrix containing benzoic acid along with sulfuric acid, ferrous sulfate, Xylenol orange, and tridistilled water. Dosimeter samples are prepared in standard vials for in‐phantom irradiation and further characterization by spectrophotometry measuring visible light transmission and absorbance before and after irradiation. Samples are irradiated using typical X‐ray tubes for radiology and calibrated Farmer‐type ionization chamber is used as reference to measure dose rates inside phantoms at vial locations. Once sensitive material composition is optimized, dose‐response curves show significant improvement regarding overall sensitivity for low dose levels. The aim of this work consists of implementing the optimized gel dosimeter to perform direct measurements of absorbed dose in samples irradiated during microcomputed tomography scanning in order to preliminary assess dose levels for further scanning of small animals for further applications in veterinary and paleontology. As a first attempt, dose distributions were measured in water‐equivalent phantoms having dimensions comparable to small animals, 100 to 1000 cm3, approximately. According to the obtained results, it is found that the proposed method shows satisfactory reliability and adequate performance for a promising gel dosimetry system.PACS number(s): 87.53.Bn, 87.57.uq, 87.59.‐e

11 April 2018 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
MSMauricio Santibañez
Mauricio Santibañez
YGY. Guillen
Y. Guillen
DCD. Chacón
D. Chacón
RFRodolfo Gabriel Figueroa
Rodolfo Gabriel Figueroa
MVM. Valente
M. Valente