Ika Dewi Wijayanti

Dr. Ika Dewi Wijayanti

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2023 in Polymers
Verified
Journal Article
Open access
PDF file
ARAmaliya Rasyida
Amaliya Rasyida
SHSalma Halimah
Salma Halimah
IWIka Dewi Wijayanti
Ika Dewi Wijayanti
SWSigit Tri Wicaksono
Sigit Tri Wicaksono
HNHaniffudin Nurdiansah
Haniffudin Nurdiansah
APAgung Purniawan
Agung Purniawan
We reported in this study the interrelation between the addition of 0.4, 0.8, 1.2, and 1.6 wt. % reduced graphene oxide (r-GO) into PVA/Alginate and their degradation and biocompatibility properties. The r-GO was synthesized by using the Hummer’s method. A crosslinker CaSO4 was added to prepare Alginate/PVA/r-GO Hydrogel composite. A Field Emission in Lens (FEI)-scanning electron microscopy (SEM), along with X-ray energy dispersive spectroscopy (EDS), was performed, characterizing the morphology of the composite. A compressive test was conducted, determining the mechanical properties of the composite with the highest achieved 0.0571 MPa. Furthermore, in vitro cytotoxicity was conducted to determine the biocompatibility properties of the studied composite. An MTT assay was applied to measure cell viability. In general, the presence of r-GO was found to have no significant effect on the morphology of the hydrogel. Indeed, adding 0.4% r-GO to the PVA/Alginate increased the cell viability up to 122.26 ± 0.93, indicating low toxicity. The studied composites have almost no changes in weight and shape, which proves that low degradation occurred in addition to this after 28 days of immersion in saline phosphate buffer solution. In conclusion, achieving minimal degradation and outstanding biocompatibility lead to PVA/Alginate/r-GO hydrogel composites being the most attractive materials for tissue engineering applications.

1 January 2020 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
IWIka Dewi Wijayanti
Ika Dewi Wijayanti
LMLive Mølmen
Live Mølmen
RDRoman V. Denys
Roman V. Denys
JNJean Nei
Jean Nei
SGStéphane Gorsse
Stéphane Gorsse
Volodymyr YartysVolodymyr Yartys
Volodymyr Yartys

1 January 2021 in AIP Conference Proceedings
Verified
Conference Paper
Open access
PDF file
IWIka Dewi Wijayanti
Ika Dewi Wijayanti
HAH. C. K. Agustin
H. C. K. Agustin
AHArif Hariyadi
Arif Hariyadi
In order to maintain the availability of electricity supply, a failure at the power plant is mandatory to be prevented. If damage has occurred, analysis of the root cause of failure must be prioritized to resolve the problem and prevent further damage. One of the important units in a power plant is a boiler that has a role as a steam generator producing the steam by changing the water in the liquid to the vapor phase. The quality of the (feed) water becomes one crucial factor in determining the lifetime of a boiler. Moreover, some factors related to the process variable control such as velocity, temperature, pressure, and flow rate of fluid should follow the specified design. Otherwise, the failure can occur, resulting in the unit shutting down, thus stopping the electric production. In this paper, the mechanism of the leakages that occurred at boiler bottom wall tubes of the steam power plant was investigated. Quality of (feed) water and several factors associated with the leakages such as temperature, pressure, and fluid characteristic are mainly considered the suspect contributing to the damage. Further to this, macro-and microstructural observations at the leaked tubes as the physical analysis were done. Analysis of chemical composition was performed to the (feed) water. Other factors concerned with the failure were also observed to validate the root cause analysis and mechanism of the leakages. Chemical analysis of (feed) water shows that the excess content of hydrazine (N2H4) as an inhibitor of corrosion is 100 times more than specified representing the low-quality level of (feed) water which significantly influences the aggressiveness of the water. In addition to this, an intentional turbulence of the flow rate of (feed) water shown by having a Reynold number of 33,000 together with the contaminated (feed) water significantly increases the risk of failure at the inner tube. Macro observation exhibits a sectional reduction on the upper curve radius at the leaked tubes indicating that a loss of product reaction between the outer tube surface with a suspicious variable occurred during the operation. Moreover, a damage to the protective magnetite layer was particularly found around the leakage denoting that a local failure happened at the inner surface tube. On the other hand, micro observation shows a local plastic deformation implying an increase of high local temperature around the leaked tubes. To conclude, the tube leakages are mainly resulted from the collaboration of suspicious factors originating from the ambient environment on both sides of the tubes. Indeed, the low level of water quality, the high turbulence of flow rate, and the increasing of local temperature during operation at inner tubes successfully caused the erosion corrosion. While the suspicious factor at outer tube, such as the fuel, led to induce the pitting corrosion. In this case, both corrosions are responsible factors to encourage the failure.

4 September 2024 in SEWAGATI
Verified
Journal Article
Open access
PDF file
IWIka Dewi Wijayanti
Ika Dewi Wijayanti
PSPutu Suwarta
Putu Suwarta
SSSutikno Sutikno
Sutikno Sutikno
FMFahmi Mubarok
Fahmi Mubarok
HAH.C. Kis Agustin
H.C. Kis Agustin
ISIndra Sidharta
Indra Sidharta
Robries adalah perusahaan daur ulang limbah plastik di Surabaya yang didirikan pada tahun 2018 oleh alumni Desain Produk ITS. Perusahaan ini bertujuan mengurangi limbah termoplastik dengan mengolahnya menjadi perabot rumah tangga seperti bangku, lemari, dan pot bunga, serta tutup botol dan wadah kosmetik. Namun, beberapa masalah dalam produk daur ulangnya, seperti penyusutan yang tidak terkontrol, dimensi produk yang tidak konsisten serta void, menyebabkan Robries kesulitan untuk memasarkan produknya ke luar negeri. Berdasarkan pengamatan Tim Departemen Teknik Mesin (DTM) ITS di pabrik, diketahui bahwa selama proses pencetakan berlangsung, distribusi temperatur pada peralatan oven yang ada saat ini tidak merata sehingga menyebabkan penyusutan dan dimensi produk yang tidak konsisten. Langkah yang dilakukan oleh tim DTM ITS adalah dengan melakukan pengukuran temperatur dan studi peralatan oven yang ada lalu solusi yang ditawarkan adalah (1) memastikan temperatur pemanasan di oven sudah merata sebelum memasukkan limbah termoplastik dan (2) re-design peralatan oven yang ada saat ini dengan menambahkan sistem pendinginan untuk memastikan distribusi panas di dalam oven merata sehingga produk memiliki dimensi yang konsisten dan cacat seminimal mungkin. Cacat yang dihasilkan lebih sedikit setelah menggunakan kedua solusi tersebut sehingga dapat disimpulkan kualitas produk daur ulang plastik telah ditingkatkan.

22 May 2025 in Results in Engineering
Verified
Journal Article
Open access
IWIka Dewi Wijayanti
Ika Dewi Wijayanti
SSSastya Adzani Syahbania
Sastya Adzani Syahbania
ISIndra Sidharta
Indra Sidharta
SUSutikno
Sutikno
UUUbaidillah Ubaidillah
Ubaidillah Ubaidillah

14 April 2025 in Journal of Electrochemical Science and Engineering
Verified
Journal Article
Open access
PDF file
IWIka Dewi Wijayanti
Ika Dewi Wijayanti
DPDelia Salsabila Putri
Delia Salsabila Putri
FDFarhan Dzikriansyah
Farhan Dzikriansyah
ISIndra Sidharta
Indra Sidharta
SSSutikno Sutikno
Sutikno Sutikno
The performance of metal hydride batteries depends on their electrochemical and kinetic behaviour, which varies with the state of charge (SoC). This study explores these characteristics in nickel-metal hydride batteries with A2B7 and AB5 electrodes, focusing on how SoC influences ion diffusion and charge transfer kinetics of the batteries. Electro¬chemical impedance spectroscopy and cyclic voltammetry (CV) were used to analyse these behaviours, while X-ray diffraction provided structural insights and scanning electron microscopy proposed morphological concepts. Results reveal a positive correlation between SoC and both diffusion and kinetic behaviour. The value of fitting resistances decreases as SoC increases, reaching a minimum at 100 % SoC, where hydrogen diffusion is optimized. CV data supports this phenomenon, showing a more negative peak cathodic current (Ip,c) at higher SoC, indicating improved kinetics likely due to enhanced ion availability. Additionally, voltage window analysis showed maximum hydrogen storage at 100 % SoC for AB5 and 50 % for A2B7. Structurally, larger particle sizes and crystallites at higher SoC correlate with increased hydrogen desorption capacity. A2B7 exhibited superior diffusion kinetics, while AB5 demonstrated better discharge behaviour, highlighting how SoC-dependent diffusion and kinetics impact Ni-MH performance.