A very promising alternative to the state-of-the-art static volume measurements for liquefied natural gas (LNG) custody transfer processes is the dynamic principle of flow metering. As the Designated Institute (DI) of the LNE (‘Laboratoire National de métrologie et d’Essais’, being the French National Metrology Institute) for high-pressure gas flow metering, Cesame–Exadebit is involved in various research and development programs. Within the framework of the first (2010–2013) and second (2014–2017) EURAMET Joint Research Project (JRP), named ‘Metrological support for LNG custody transfer and transport fuel applications’, Cesame–Exadebit explored a novel cryogenic flow metering technology using laser Doppler velocimetry (LDV) as an alternative to ultrasonic and Coriolis flow metering. Cesame–Exadebit is trying to develop this technique as a primary standard for cryogenic flow meters. Currently, cryogenic flow meters are calibrated at ambient temperatures with water. Results are then extrapolated to be in the Reynolds number range of real applications. The LDV standard offers a unique capability to perform online calibration of cryogenic flow meters in real conditions (temperature, pressure, piping and real flow disturbances). The primary reference has been tested on an industrial process in a LNG terminal during truck refuelling. The reference can calibrate Coriolis flow meters being used daily with all the real environmental constraints, and its utilisation is transparent for LNG terminal operators. The standard is traceable to Standard International units and the combined extended uncertainties have been determined and estimated to be lower than 0.6% (an ongoing improvement to reducing the correlation function uncertainty, which has a major impact in the uncertainty estimation).
We present the first European intercomparison of primary flow measurement standards with hydrogen-enriched natural gas (up to 20% hydrogen in molar fraction) and natural gas with pressure up to 60 bar and volume flow rates in the range (5 to 160) m3/h. We describe the principles of operation of the primary standards and present the transfer standards, a rotary meter and an ultrasonic meter, used for the intercomparison. In many instances, the overlap between the different laboratories is satisfactory, but the collected results are limited and do not allow us to make advanced conclusions. In addition, we investigate the effect of nitrogen impurities (2% in molar fraction) on the performance of low-pressure gas meters for pure hydrogen using newly developed measurement standards. We present the methods and results of this investigation. We show that nitrogen impurities affect the volume flow measurements of an ultrasonic meter but seem to have little effect on a thermal mass flow meter. This paper explores future opportunities and challenges in international intercomparisons involving hydrogen blends and highlights key issues and solutions with hydrogen gas metering in the presence of impurities.
Ce travail tente d'analyser la réponse d'une jet axisymétrique turbulent à une excitation fluidique stationnaire et instationnaire lorsque le contenu fréquentiel et aziumutal (!,m) de la perturbation est maîtrisé. Le dispositif de contrôle utilisé est composé de 16 microjets ronds répartis sur le bord de fuite de la tuyère. L'utilisation des microjets provoque une réduction du champ acoustique rayonné (particulièrement pour le cas de contrôle stationnaire). Le champ aérodynamique est ensuite sondé grâce à des mesures fil chaud et PIV stéréoscopique résolue en temps. L'excitation instationnaire permet d'utiliser les moyennes de phase afin d'effectuer une décomposition triple du champ de vitesse. L'étude de la composante cyclique de la “réponse du jet” montre une synchronisation spatio-temporelle importante sur une grande étendue spatiale. En d'autres mots, le forçage a une grande autorité déterministe sur l'écoulement. De plus, la comparaison de la composante cyclique de la réponse du jet avec la théorie de la stabilité linéaire indique qu'il existe des ondes d'instabilité hydrodynamique au sein du jet. L'analyse du jet contrôlé par injection fluidique stationnaire montre ensuite comment l'effet du contrôle peut être expliqué par la déformation du champ moyen conduisant à la réduction du taux de croissance des ondes d'instabilité dans le jet. Cette déformation est dûe à l'introduction d'un couple de paramètre (nombre d'onde/fréquences) pour lequel le champ moyen de l'écoulement est stable. La réponse du jet étant turbulente, cela implique que les tensions de Reynolds déforment le champ moyen de manière à ce que les modes les plus instables aient des taux de croissance plus faibles.