Noemi Pisani

Mrs. Noemi Pisani

orcid
Postdoctoral Researcher

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 December 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
Leandro DonisiLeandro Donisi
Leandro Donisi
Giuseppe CesarelliGiuseppe Cesarelli
Giuseppe Cesarelli
NPNoemi Pisani
Noemi Pisani
Alfonso Maria PonsiglioneAlfonso Maria Ponsiglione
Alfonso Maria Ponsiglione
Carlo RicciardiCarlo Ricciardi
Carlo Ricciardi
Edda CapodaglioEdda Capodaglio
Edda Capodaglio
Physical ergonomics has established itself as a valid strategy for monitoring potential disorders related, for example, to working activities. Recently, in the field of physical ergonomics, several studies have also shown potential for improvement in experimental methods of ergonomic analysis, through the combined use of artificial intelligence, and wearable sensors. In this regard, this review intends to provide a first account of the investigations carried out using these combined methods, considering the period up to 2021. The method that combines the information obtained on the worker through physical sensors (IMU, accelerometer, gyroscope, etc.) or biopotential sensors (EMG, EEG, EKG/ECG), with the analysis through artificial intelligence systems (machine learning or deep learning), offers interesting perspectives from both diagnostic, prognostic, and preventive points of view. In particular, the signals, obtained from wearable sensors for the recognition and categorization of the postural and biomechanical load of the worker, can be processed to formulate interesting algorithms for applications in the preventive field (especially with respect to musculoskeletal disorders), and with high statistical power. For Ergonomics, but also for Occupational Medicine, these applications improve the knowledge of the limits of the human organism, helping in the definition of sustainability thresholds, and in the ergonomic design of environments, tools, and work organization. The growth prospects for this research area are the refinement of the procedures for the detection and processing of signals; the expansion of the study to assisted working methods (assistive robots, exoskeletons), and to categories of workers suffering from pathologies or disabilities; as well as the development of risk assessment systems that exceed those currently used in ergonomics in precision and agility.

9 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
MRMichela Russo
Michela Russo
MAMarianna Amboni
Marianna Amboni
NPNoemi Pisani
Noemi Pisani
AVAntonio Volzone
Antonio Volzone
DCDanilo Calderone
Danilo Calderone
MRMaria Romano
Maria Romano
Parkinson’s disease (PD) is characterized by a slow, short-stepping, shuffling gait pattern caused by a combination of motor control limitations due to a reduction in dopaminergic neurons. Gait disorders are indicators of global health, cognitive status, and risk of falls and increase with disease progression. Therefore, the use of quantitative information on the gait mechanisms of PD patients is a promising approach, particularly for monitoring gait disorders and potentially informing therapeutic interventions, though it is not yet a well-established tool for early diagnosis or direct assessment of disease progression. Over the years, many studies have investigated the spatiotemporal parameters that are altered in the PD gait pattern, while kinematic and kinetic gait parameters are more limited. A scoping review was performed according to the PRISMA guidelines. The Scopus and PubMed databases were searched between 1999 and 2023. A total of 29 articles were included that reported gait changes in PD patients under different gait conditions: single free walking, sequential motor task, and dual task. The main findings of our review highlighted the use of optoelectronic systems for recording kinematic parameters and force plates for measuring kinetic parameters, due to their high accuracy. Most gait analyses in PD patients have been conducted at self-selected walking speeds to capture natural movement, although studies have also examined gait under various conditions. The results of our review indicated that PD patients experience alterations in the range of motion of the hip, knee, and ankle joints, as well as a reduction in the power generated/absorbed and the extensor/flexor moments. These findings suggest that the PD gait pattern may be more effectively understood using kinematic and kinetic parameters.

16 December 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Carlo RicciardiCarlo Ricciardi
Carlo Ricciardi
NPNoemi Pisani
Noemi Pisani
Leandro DonisiLeandro Donisi
Leandro Donisi
FAFilomena Abate
Filomena Abate
MAMarianna Amboni
Marianna Amboni
Francesco AmatoFrancesco Amato
Francesco Amato
The use of wearable sensors for calculating gait parameters has become increasingly popular as an alternative to optoelectronic systems, currently recognized as the gold standard. The objective of the study was to evaluate the agreement between the wearable Opal system and the optoelectronic BTS SMART DX system for assessing spatiotemporal gait parameters. Fifteen subjects with progressive supranuclear palsy walked at their self-selected speed on a straight path, and six spatiotemporal parameters were compared between the two measurement systems. The agreement was carried out through paired data test, Passing Bablok regression, and Bland-Altman Analysis. The results showed a perfect agreement for speed, a very close agreement for cadence and cycle duration, while, in the other cases, Opal system either under- or over-estimated the measurement of the BTS system. Some suggestions about these misalignments are proposed in the paper, considering that Opal system is widely used in the clinical context.

8 April 2025 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Open access
NPNoemi Pisani
Noemi Pisani
Michela DestitoMichela Destito
Michela Destito
Carlo RicciardiCarlo Ricciardi
Carlo Ricciardi
MPMaria Teresa Pellecchia
Maria Teresa Pellecchia
Mario CesarelliMario Cesarelli
Mario Cesarelli
Francesco AmatoFrancesco Amato
Francesco Amato
Radiomics extracts quantitative features from magnetic resonance images (MRI) and is especially useful in the presence of subtle pathological changes within human soft tissues. This scenario, however, may not cover the effects of intrinsic, e.g., aging-related, (physiological) neurodegeneration of normal brain tissue. The aim of the work was to study the repeatability of radiomic features extracted from an apparently normal area in longitudinally acquired T1-weighted MR brain images using three different intensity normalization approaches typically used in radiomics: Z-score, WhiteStripe and Nyul. Fifty-nine images of hearing impaired, yet cognitively intact, patients were repeatedly acquired in two different time points within six months. Ninety-one radiomic features were obtained from an area within the pons region, considered to be a healthy brain tissue according to previous analyses and reports. The Intraclass Correlation Coefficient (ICC) and the Concordance Correlation Coefficient (CCC) in the repeatability study were used as metrics. Features extracted from the MRI normalized with Z-score showed results comparable in both ICC (0.90 (0.82-0.98)) and CCC (0.82 (0.69-0.95)) distribution values, in terms of median and quartiles, with those extracted from the images normalized with WhiteStripe (0.89 (0.84-0.92)) and (0.80 (0.73-0.84)), respectively. Our findings underline the importance of, providing useful guidelines for, the intensity normalization of brain MRI prior to a longitudinal radiomic analysis.

28 February 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
MCMartina Caruso
Martina Caruso
Arnaldo StanzioneArnaldo Stanzione
Arnaldo Stanzione
Carlo RicciardiCarlo Ricciardi
Carlo Ricciardi
FDFabiola Di Dato
Fabiola Di Dato
NPNoemi Pisani
Noemi Pisani
Simone MaureaSimone Maurea
Simone Maurea
Kasai portoenterostomy (KP) plays a crucial role in the treatment of biliary atresia (BA). The aim is to correlate MRI quantitative findings of native liver survivor BA patients after KP with a medical outcome. Thirty patients were classified as having ideal medical outcomes (Group 1; n = 11) if laboratory parameter values were in the normal range and there was no evidence of chronic liver disease complications; otherwise, they were classified as having nonideal medical outcomes (Group 2; n = 19). Liver and spleen volumes, portal vein diameter, liver mean, and maximum and minimum ADC values were measured; similarly, ADC and T2-weighted textural parameters were obtained using ROI analysis. The liver volume was significantly (p = 0.007) lower in Group 2 than in Group 1 (954.88 ± 218.31 cm3 vs. 1140.94 ± 134.62 cm3); conversely, the spleen volume was significantly (p < 0.001) higher (555.49 ± 263.92 cm3 vs. 231.83 ± 70.97 cm3). No differences were found in the portal vein diameter, liver ADC values, or ADC and T2-weighted textural parameters. In conclusion, significant quantitative morpho-volumetric liver and spleen abnormalities occurred in BA patients with nonideal medical outcomes after KP, but no significant microstructural liver abnormalities detectable by ADC values and ADC and T2-weighted textural parameters were found between the groups.