Mario Cesarelli

Prof. Dr. Mario Cesarelli

1. Istituti Clinici Scientifici Maugeri IRCCS , Pavia, Italy
+1

Research Focus & Metrics

Academic Career Length

43Years (1984-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Nawadita ParajuliNawadita Parajuli
Nawadita Parajuli
NSNeethu Sreenivasan
Neethu Sreenivasan
Paolo BifulcoPaolo Bifulco
Paolo Bifulco
Mario CesarelliMario Cesarelli
Mario Cesarelli
SSSergio Savino
Sergio Savino
GGGaetano Gargiulo
Gaetano Gargiulo
Upper limb amputation is a condition that significantly restricts the amputees from performing their daily activities. The myoelectric prosthesis, using signals from residual stump muscles, is aimed at restoring the function of such lost limbs seamlessly. Unfortunately, the acquisition and use of such myosignals are cumbersome and complicated. Furthermore, once acquired, it usually requires heavy computational power to turn it into a user control signal. Its transition to a practical prosthesis solution is still being challenged by various factors particularly those related to the fact that each amputee has different mobility, muscle contraction forces, limb positional variations and electrode placements. Thus, a solution that can adapt or otherwise tailor itself to each individual is required for maximum utility across amputees. Modified machine learning schemes for pattern recognition have the potential to significantly reduce the factors (movement of users and contraction of the muscle) affecting the traditional electromyography (EMG)-pattern recognition methods. Although recent developments of intelligent pattern recognition techniques could discriminate multiple degrees of freedom with high-level accuracy, their efficiency level was less accessible and revealed in real-world (amputee) applications. This review paper examined the suitability of upper limb prosthesis (ULP) inventions in the healthcare sector from their technical control perspective. More focus was given to the review of real-world applications and the use of pattern recognition control on amputees. We first reviewed the overall structure of pattern recognition schemes for myo-control prosthetic systems and then discussed their real-time use on amputee upper limbs. Finally, we concluded the paper with a discussion of the existing challenges and future research recommendations.

27 December 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
GPGiuseppe Prisco
Giuseppe Prisco
MPMaria Agnese Pirozzi
Maria Agnese Pirozzi
ASAntonella Santone
Antonella Santone
FEFabrizio Esposito
Fabrizio Esposito
Mario CesarelliMario Cesarelli
Mario Cesarelli
Leandro DonisiLeandro Donisi
Leandro Donisi
Background/Objectives: Gait analysis, traditionally performed with lab-based optical motion capture systems, offers high accuracy but is costly and impractical for real-world use. Wearable technologies, especially inertial measurement units (IMUs), enable portable and accessible assessments outside the lab, though challenges with sensor placement, signal selection, and algorithm design can affect accuracy. This systematic review aims to bridge the benchmarking gap between IMU-based and traditional systems, validating the use of wearable inertial systems for gait analysis. Methods: This review examined English studies between 2012 and 2023, retrieved from the Scopus database, comparing wearable sensors to optical motion capture systems, focusing on IMU body placement, gait parameters, and validation metrics. Exclusion criteria for the search included conference papers, reviews, unavailable papers, studies without wearable inertial sensors for gait analysis, and those not involving agreement studies or optical motion capture systems. Results: From an initial pool of 479 articles, 32 were selected for full-text screening. Among them, the lower body resulted in the most common site for single IMU placement (in 22 studies), while the most frequently used multi-sensor configuration involved IMU positioning on the lower back, shanks, feet, and thighs (10 studies). Regarding gait parameters, 11 studies out of the 32 included studies focused on spatial-temporal parameters, 12 on joint kinematics, 2 on gait events, and the remainder on a combination of parameters. In terms of validation metrics, 24 studies employed correlation coefficients as the primary measure, while 7 studies used a combination of error metrics, correlation coefficients, and Bland–Altman analysis. Validation metrics revealed that IMUs exhibited good to moderate agreement with optical motion capture systems for kinematic measures. In contrast, spatiotemporal parameters demonstrated greater variability, with agreement ranging from moderate to poor. Conclusions: This review highlighted the transformative potential of wearable IMUs in advancing gait analysis beyond the constraints of traditional laboratory-based systems.

1 May 2010 in Clinical Neurophysiology
Verified
Journal Article
Closed access
GGGaetano Gargiulo
Gaetano Gargiulo
RCRafael A. Calvo
Rafael A. Calvo
PBPaolo Bifulco
Paolo Bifulco
Mario CesarelliMario Cesarelli
Mario Cesarelli
CJCraig Jin
Craig Jin
ASAndre van Schaik
Andre van Schaik

14 August 2015 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
Antonio FratiniAntonio Fratini
Antonio Fratini
MSMario Sansone
Mario Sansone
Paolo BifulcoPaolo Bifulco
Paolo Bifulco
Mario CesarelliMario Cesarelli
Mario Cesarelli
During last decade the use of ECG recordings in biometric recognition studies has increased. ECG characteristics made it suitable for subject identification: it is unique, present in all living individuals, and hard to forge. However, in spite of the great number of approaches found in literature, no agreement exists on the most appropriate methodology. This study aimed at providing a survey of the techniques used so far in ECG-based human identification. Specifically, a pattern recognition perspective is here proposed providing a unifying framework to appreciate previous studies and, hopefully, guide future research. We searched for papers on the subject from the earliest available date using relevant electronic databases (Medline, IEEEXplore, Scopus, and Web of Knowledge). The following terms were used in different combinations: electrocardiogram, ECG, human identification, biometric, authentication and individual variability. The electronic sources were last searched on 1st March 2015. In our selection we included published research on peer-reviewed journals, books chapters and conferences proceedings. The search was performed for English language documents. 100 pertinent papers were found. Number of subjects involved in the journal studies ranges from 10 to 502, age from 16 to 86, male and female subjects are generally present. Number of analysed leads varies as well as the recording conditions. Identification performance differs widely as well as verification rate. Many studies refer to publicly available databases (Physionet ECG databases repository) while others rely on proprietary recordings making difficult them to compare. As a measure of overall accuracy we computed a weighted average of the identification rate and equal error rate in authentication scenarios. Identification rate resulted equal to 94.95 % while the equal error rate equal to 0.92 %. Biometric recognition is a mature field of research. Nevertheless, the use of physiological signals features, such as the ECG traits, needs further improvements. ECG features have the potential to be used in daily activities such as access control and patient handling as well as in wearable electronics applications. However, some barriers still limit its growth. Further analysis should be addressed on the use of single lead recordings and the study of features which are not dependent on the recording sites (e.g. fingers, hand palms). Moreover, it is expected that new techniques will be developed using fiducials and non-fiducial based features in order to catch the best of both approaches. ECG recognition in pathological subjects is also worth of additional investigations.

3 December 2018 in BMC Health Services Research
Verified
Journal Article
Open access
PDF file
Giovanni ImprotaGiovanni Improta
Giovanni Improta
Maria RomanoMaria Romano
Maria Romano
MCMaria Vincenza Di Cicco
Maria Vincenza Di Cicco
AFAnna Ferraro
Anna Ferraro
ABAnna Borrelli
Anna Borrelli
Mario CesarelliMario Cesarelli
Mario Cesarelli
Throughout the world, emergency departments (ED) are characterized by overcrowding and excessive waiting times. Furthermore, the related delays significantly increase patient mortality and make inefficient use of resources to the detriment of the satisfaction of employees and patients. In this work, lean thinking is applied to the ED of Cardarelli Hospital of Naples with the aim of increasing patient flow, improving the processes that contribute to facilitating the flow of patients through the various stages of medical treatment and eliminating all bottlenecks (queue) as well as all activities that generate waste. This project was performed at National Hospital A.O.R.N. A. Cardarelli of Naples. The historical times of access to the ED were analysed from January 2015 to June 2015, for a total of 16,563 records. Subsequently, starting in November 2015, corrective actions were implemented according to the Lean Approach. Data collected after the introduced improvements were collected from April 2016 to June 2016 and compared to those collected during the starting period. The results acquired before application of the Lean Thinking strategy illustrated the as-is process with its drawbacks. An analysis of the non-added value activities was performed to identify the procedures that need to be improved. After implementation of the corrective actions, we observed a positive increase in the performance of the ED, quantified as percentages of hospitalized patients according to triage codes and waiting times. This work demonstrates the applicability of Lean Thinking to ED processes and its effectiveness in terms of increasing the efficiency of services and reducing waste (waiting times).

1 August 2009 in Journal of Electromyography and Kinesiology
Verified
Journal Article
Closed access
Antonio FratiniAntonio Fratini
Antonio Fratini
Mario CesarelliMario Cesarelli
Mario Cesarelli
PBPaolo Bifulco
Paolo Bifulco
MRMaria Romano
Maria Romano