Gabriel Orquizas Mattielo Pedroso

Dr. Gabriel Orquizas Mattielo Pedroso

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2023 in Materials
Verified
Journal Article
Open access
PDF file
TATalita Andrade da Costa Almeida
Talita Andrade da Costa Almeida
EFEmerson Felipe Félix
Emerson Felipe Félix
CSCarlos Manuel Andrade de Sousa
Carlos Manuel Andrade de Sousa
GPGabriel Orquizas Mattielo Pedroso
Gabriel Orquizas Mattielo Pedroso
Mariana Ferreira Benessiuti MottaMariana Ferreira Benessiuti Motta
Mariana Ferreira Benessiuti Motta
LPLisiane Pereira Prado
Lisiane Pereira Prado
The artificial neural networks (ANNs)-based model has been used to predict the compressive strength of concrete, assisting in creating recycled aggregate concrete mixtures and reducing the environmental impact of the construction industry. Thus, the present study examines the effects of the training algorithm, topology, and activation function on the predictive accuracy of ANN when determining the compressive strength of recycled aggregate concrete. An experimental database of compressive strength with 721 samples was defined considering the literature. The database was used to train, validate, and test the ANN-based models. Altogether, 240 ANNs were trained, defined by combining three training algorithms, two activation functions, and topologies with a hidden layer containing 1–40 neurons. The ANN with a single hidden layer including 28 neurons, trained with the Levenberg–Marquardt algorithm and the hyperbolic tangent function, achieved the best level of accuracy, with a coefficient of determination equal to 0.909 and a mean absolute percentage error equal to 6.81%. Furthermore, the results show that it is crucial to avoid the use of overly complex models. Excessive neurons can lead to exceptional performance during training but poor predictive ability during testing.

4 June 2023 in Materials
Verified
Journal Article
Open access
PDF file
GPGabriel Orquizas Mattielo Pedroso
Gabriel Orquizas Mattielo Pedroso
RJRicardo Domingos dos Santos Junior
Ricardo Domingos dos Santos Junior
Jefferson Lins da SilvaJefferson Lins da Silva
Jefferson Lins da Silva
Mariana Ferreira Benessiuti MottaMariana Ferreira Benessiuti Motta
Mariana Ferreira Benessiuti Motta
EFEmerson Felipe Félix
Emerson Felipe Félix
This work deals with the flexural performance of a soil-cement for pavement reinforced by polypropylene and steel fibers, and the main purpose is to evaluate the effect of different curing times. In this sense, three different curing times were employed to investigate the influence of fibers on the material’s behavior at varying levels of strength and stiffness as the matrix became increasingly rigid. An experimental program was developed to analyze the effects of incorporating different fibers in a cemented matrix for pavement applications. Polypropylene and steel fibers were used at 0.5/1.0/1.5% fractions by volume for three different curing times (3/7/28 days) to assess the fiber effect in the cemented soil (CS) matrices throughout time. An evaluation of the material performance was carried out using the 4-Point Flexural Test. The results show that steel fibers with 1.0% content improved by approximately 20% in terms of initial strength and peak strength at small deflections without interfering the flexural static modulus of the material. The polypropylene fiber mixtures had better performance in terms of ductility index reaching values varying from 50 to 120, an increase of approximately 40% in residual strength, and improved cracking control at large deflections. The current study shows that fibers significantly affect the mechanical performance of CSF. Thus, the overall performance presented in this study is useful for selecting the most suitable fiber type corresponding to the different mechanisms as a function of curing time.

2 June 2023 in Materials
Verified
Journal Article
Open access
PDF file
Jefferson Lins da SilvaJefferson Lins da Silva
Jefferson Lins da Silva
CVClever Valentin
Clever Valentin
MKMarcelo Kobelink
Marcelo Kobelink
GPGabriel Orquizas Mattielo Pedroso
Gabriel Orquizas Mattielo Pedroso
Maria Aparicio ArdilaMaria Aparicio Ardila
Maria Aparicio Ardila
Marta LuzMarta Luz
Marta Luz
A Hydroelectric Power Plant (HPP) presents erosion problems on reservoir slopes and margins. Geomats are a biotechnical composite technology increasingly used to protect soils against erosion. Survivability or durability of geomats is essential for successful application. This work analyses the degradation of geomats exposed in the field for more than six years. These geomats were used as erosion-control treatment in a slope at HPP Simplício in Brazil. The degradation of the geomats in the laboratory was also analysed through exposure in a UV ageing chamber for 500 h and 1000 h. Degradation was quantitatively evaluated by testing the tensile strength of the geomat wires and thermal tests such as thermogravimetry (TG) and differential scanning calorimetry (DSC). The results showed that the geomat wires exposed in the field had a greater decrease in resistance compared to the samples exposed in the laboratory. In the samples collected in the field, it could be observed that the degradation of the virgin sample occurred earlier than in the exposed samples, contrary to what was observed in the TG tests carried out with the samples exposed in the laboratory. The DSC analysis showed that the samples had similar behaviours for the melting peaks. This evaluation of the wires of the geomats was presented as an alternative to analysing the tensile strengths of discontinuous geosynthetic materials such as the geomats.

27 December 2023 in Water
Verified
Journal Article
Open access
PDF file
VAVitor Yudi Góes Adachi
Vitor Yudi Góes Adachi
JRJoan Steven Flores Rodríguez
Joan Steven Flores Rodríguez
Mariana Ferreira Benessiuti MottaMariana Ferreira Benessiuti Motta
Mariana Ferreira Benessiuti Motta
GPGabriel Orquizas Mattielo Pedroso
Gabriel Orquizas Mattielo Pedroso
LHLuis Rogerio de Oliveira Oliveira Hein
Luis Rogerio de Oliveira Oliveira Hein
EFEmerson Felipe Félix
Emerson Felipe Félix
This research aims to assess the clogging process of geotextiles within silt fences. For that purpose, the filtering efficiency, flow rate, and clogging of three geotextiles (GTX-1, GTX-2, and GTX-3) employing two distinct soils and under three sediment discharge cycles were investigated. The analysis adhered to the American standard D5141-11 and, as further analyses, qualitative and quantitative inspections were conducted through microscopic images of the materials. The results showed greater clogging of the nonwoven geotextile, GTX-1, with higher retention efficiency (approximately 100%) and better turbidity removal for both soils, equal to a reduction of around 94%. For GTX-2, a woven geotextile with a larger pore opening, less intense clogging and lower retention efficiency were observed after the third discharge; the average was 96% for both soils. GTX-3, a woven geotextile with a smaller apparent opening, exhibited a behavior similar to GTX-1: as the number of cycles increased, the material experienced more clogging and higher retention efficiency for soil 1 (approximately 98.5%). Based on these findings, it can be inferred that the discharge cycles impact the tested geotextiles in diverse ways and, therefore, the selection of the material should be contingent on project requirements.

4 July 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SBSergio Rincón Barajas
Sergio Rincón Barajas
GPGabriel Orquizas Mattielo Pedroso
Gabriel Orquizas Mattielo Pedroso
Fernanda Bessa FerreiraFernanda Bessa Ferreira
Fernanda Bessa Ferreira
Jefferson Lins da SilvaJefferson Lins da Silva
Jefferson Lins da Silva
Geosynthetics have increasingly been applied to geotechnical engineering works due to their numerous advantages, including cost-effectiveness and their significant role in sustainable development. When geosynthetics are used as reinforcement in earth structures, such as embankments, retaining walls and bridge abutments, soil–geosynthetic interface shear behavior is a critical parameter involved in the design. This paper presents a series of monotonic and cyclic/post-cyclic pullout tests carried out to examine the apparatus scale effect on the pullout response of a geogrid embedded in two different soils. To assess the small-scale equipment feasibility, comparisons were made between pullout test parameters derived from small- and large-scale equipment. The test results indicate that, under a low confining stress of 25 kPa, using a smaller-sized apparatus results in lower values of geogrid pullout resistance and maximum mobilized shear stress, but higher values of confined tensile stiffness at low strains. On the other hand, as the confining stress increases (i.e., 50 kPa and 100 kPa), the difference between the results becomes less significant and similar trends are observed regardless of the equipment type. Adopting small-scale equipment enables obtaining soil–reinforcement interaction parameters using test procedures that are less time-consuming than those associated with large-scale pullout tests. However, proper scale effect correction factors may be considered for more consistent estimates of the interface strength parameters under low normal stress values.

1 January 2026 in International Journal of Polymer Science
Verified
Journal Article
Open access
PDF file
CVClever Valentin
Clever Valentin
Jefferson Lins da SilvaJefferson Lins da Silva
Jefferson Lins da Silva
MKMarcelo Kobelink
Marcelo Kobelink
Marta LuzMarta Luz
Marta Luz
Maria Aparicio ArdilaMaria Aparicio Ardila
Maria Aparicio Ardila
MSMarcell Gustavo Chagas Santos
Marcell Gustavo Chagas Santos
This study evaluates the long‐term durability of two commercial nonwoven geotextiles—polypropylene (PP) and polyester (PET)—subjected to natural weathering for up to 36 months. The materials were analyzed using mechanical tests (tensile strength, puncture resistance), thermal methods (TGA, DSC, and DMA), and scanning electron microscopy (SEM) to assess degradation in their physical, mechanical, and microstructural properties. Results showed significantly higher degradation in the PP geotextile compared with PET, with up to 84% loss in tensile strength after 36 months. The PET geotextile retained more than 50% of its strength, not reaching the 50% degradation threshold within the study period. Thermal analyses confirmed changes in molecular structure, with PP showing a more pronounced loss of thermal stability. SEM images further supported these findings, revealing greater fiber damage in PP. The findings highlight the superior performance of PET geotextiles under long‐term environmental exposure, supporting their selection in applications requiring enhanced durability.