Samuele Ghezzo

Dr. Samuele Ghezzo

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 May 2024 in European Radiology Experimental
Verified
Journal Article
Open access
PDF file
BKBurak Kocak
Burak Kocak
ABAlessandra Borgheresi
Alessandra Borgheresi
APAndrea Ponsiglione
Andrea Ponsiglione
AAAnna E. Andreychenko
Anna E. Andreychenko
ACArmando Ugo Cavallo
Armando Ugo Cavallo
Renato CuocoloRenato Cuocolo
Renato Cuocolo
Overall quality of radiomics research has been reported as low in literature, which constitutes a major challenge to improve. Consistent, transparent, and accurate reporting is critical, which can be accomplished with systematic use of reporting guidelines. The CheckList for EvaluAtion of Radiomics research (CLEAR) was previously developed to assist authors in reporting their radiomic research and to assist reviewers in their evaluation. To take full advantage of CLEAR, further explanation and elaboration of each item, as well as literature examples, may be useful. The main goal of this work, Explanation and Elaboration with Examples for CLEAR (CLEAR-E3), is to improve CLEAR’s usability and dissemination. In this international collaborative effort, members of the European Society of Medical Imaging Informatics−Radiomics Auditing Group searched radiomics literature to identify representative reporting examples for each CLEAR item. At least two examples, demonstrating optimal reporting, were presented for each item. All examples were selected from open-access articles, allowing users to easily consult the corresponding full-text articles. In addition to these, each CLEAR item’s explanation was further expanded and elaborated. For easier access, the resulting document is available at https://radiomic.github.io/CLEAR-E3/. As a complementary effort to CLEAR, we anticipate that this initiative will assist authors in reporting their radiomics research with greater ease and transparency, as well as editors and reviewers in reviewing manuscripts.Relevance statement Along with the original CLEAR checklist, CLEAR-E3 is expected to provide a more in-depth understanding of the CLEAR items, as well as concrete examples for reporting and evaluating radiomic research.Key points• As a complementary effort to CLEAR, this international collaborative effort aims to assist authors in reporting their radiomics research, as well as editors and reviewers in reviewing radiomics manuscripts.• Based on positive examples from the literature selected by the EuSoMII Radiomics Auditing Group, each CLEAR item explanation was further elaborated in CLEAR-E3.• The resulting explanation and elaboration document with examples can be accessed at https://radiomic.github.io/CLEAR-E3/. Graphical Abstract

9 November 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
PMPaola Mapelli
Paola Mapelli
SGSamuele Ghezzo
Samuele Ghezzo
AGAna Maria Samanes Gajate
Ana Maria Samanes Gajate
EPErik Preza
Erik Preza
GBGiorgio Brembilla
Giorgio Brembilla
Maria PicchioMaria Picchio
Maria Picchio
The aim of the present study is to investigate the synergic role of 68Ga-PSMA PET/MRI and 68Ga-DOTA-RM2 PET/MRI in prostate cancer (PCa) staging. We present pilot data on twenty-two patients with biopsy-proven PCa that underwent 68Ga-PSMA PET/MRI for staging purposes, with 19/22 also undergoing 68Gaa-DOTA-RM2 PET/MRI. TNM classification based on image findings was performed and quantitative imaging parameters were collected for each scan. Furthermore, twelve patients underwent radical prostatectomy with the availability of histological data that were used as the gold standard to validate intraprostatic findings. A DICE score between regions of interest manually segmented on the primary tumour on 68Ga-PSMA PET, 68Ga-DOTA-RM2 PET and on T2 MRI was computed. All imaging modalities detected the primary PCa in 18/19 patients, with 68Ga-DOTA-RM2 PET not detecting any lesion in 1/19 patients. In the remaining patients, 68Ga-PSMA and MRI were concordant. Seven patients presented seminal vesicles involvement on MRI, with two of these being also detected by 68Ga-PSMA, and 68Ga-DOTA-RM2 PET being negative. Regarding extraprostatic disease, 68Ga-PSMA PET, 68Ga-DOTA-RM2 PET and MRI resulted positive in seven, four and five patients at lymph-nodal level, respectively, and at a bone level in three, zero and one patients, respectively. These preliminary results suggest the potential complementary role of 68Ga-PSMA PET, 68Ga-DOTA-RM2 PET and MRI in PCa characterization during the staging phase.

11 January 2022 in Cancers
Verified
Journal Article
Open access
PDF file
PMPaola Mapelli
Paola Mapelli
SGSamuele Ghezzo
Samuele Ghezzo
AGAna Maria Samanes Gajate
Ana Maria Samanes Gajate
EPErik Preza
Erik Preza
APAnna Palmisano
Anna Palmisano
Maria PicchioMaria Picchio
Maria Picchio
The aim of the present study is to investigate and compare the performances of 68Ga-PSMA and 68Ga-DOTA-RM2 PET/MRI in identifying recurrent prostate cancer (PCa) after primary treatment and to explore the association of dual-tracer PET findings with clinical and histopathological characteristics. Thirty-five patients with biochemical relapse (BCR) of PCa underwent 68Ga PSMA PET/MRI for restaging purpose, with 31/35 also undergoing 68Ga-DOTA-RM2 PET/MRI scan within 16 days (mean: 3 days, range: 2–16 days). Qualitative and quantitative image analysis has been performed by comparing 68Ga-PSMA and 68Ga-DOTA-RM2 PET/MRI findings both on a patient and lesion basis. Clinical and instrumental follow-up was used to validate PET findings. Fisher’s exact test and Mann-Whitney U test were used to investigate the association between dual-tracer PET findings, clinical and histopathological data. p-value significance was defined below the 0.05 level. Patients’ mean age was 70 years (range: 49–84) and mean PSA at time of PET/MR scans was 1.88 ng/mL (range: 0.21–14.4). A higher detection rate was observed for 68Ga-PSMA PET/MRI, with more lesions being detected compared to 68Ga-DOTA-RM2 PET/MRI (26/35 patients, 95 lesions vs. 15/31 patients, 41 lesions; p = 0.016 and 0.002). 68Ga-PSMA and 68Ga-DOTA-RM2 PET/MRI findings were discordant in 11/31 patients; among these, 10 were 68Ga-PSMA positive (9/10 confirmed as true positive and 1/10 as false positive by follow-up examination). Patients with higher levels of PSA and shorter PSA doubling time (DT) presented more lesions on 68Ga-PSMA PET/MRI (p = 0.006 and 0.044), while no association was found between PET findings and Gleason score. 68Ga-PSMA has a higher detection rate than 68Ga-DOTA-RM2 in detecting PCa recurrence. The number of 68Ga-PSMA PET positive lesions is associated with higher levels of PSA and shorter PSA DT, thus representing potential prognostic factors.

11 July 2025 in Journal of Medical Economics
Verified
Journal Article
Open access
LML. Maas
L. Maas
CCC. Contreras-Meca
C. Contreras-Meca
SGSamuele Ghezzo
Samuele Ghezzo
FBF. Belmans
F. Belmans
ACAndrea Corsi
Andrea Corsi
JRJavier del Riego
Javier del Riego
Hepatocellular carcinoma (HCC) is the fifth most common cancer worldwide and the third most common cause of cancer-related death. Cirrhosis is a major contributing factor, accounting for over 90% of HCC cases. With the high mortality rate of HCC, earlier detection of HCC is critical. When added to magnetic resonance imaging (MRI), artificial intelligence (AI) has been shown to improve HCC detection. Nonetheless, to date no cost-effectiveness analyses have been conducted on an AI tool to enhance earlier HCC detection. This study reports on the cost-effectiveness of detection of liver lesions with AI improved MRI in the surveillance for HCC in patients with a cirrhotic liver compared to usual care (UC). The model structure included a decision tree followed by a state-transition Markov model from an Italian healthcare perspective. Lifetime costs and quality-adjusted life years (QALY) were simulated in cirrhotic patients at risk of HCC. One-way sensitivity analyses and two-way sensitivity analyses were performed. Results were presented as incremental cost-effectiveness ratios (ICER). For patients receiving UC, the average lifetime costs per 1,000 patients were €16,604,800 compared to €16,610,250 for patients receiving the AI approach. With a QALY gained of 0.55 and incremental costs of €5,000 for every 1,000 patients, the ICER was €9,888 per QALY gained, indicating cost-effectiveness with the willingness-to-pay threshold of €33,000/QALY gained. Main drivers of cost-effectiveness included the cost and performance (sensitivity and specificity) of the AI tool. This study suggests that an AI-based approach to earlier detect HCC in cirrhotic patients can be cost-effective. By incorporating cost-effective AI-based approaches in clinical practice, patient outcomes and healthcare efficiency are improved.

12 September 2023 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Closed access
PDF file
GNGaia Ninatti
Gaia Ninatti
CPCristiano Pini
Cristiano Pini
FGFabrizia Gelardi
Fabrizia Gelardi
SGSamuele Ghezzo
Samuele Ghezzo
PMPaola Mapelli
Paola Mapelli
ACArturo Chiti
Arturo Chiti

13 August 2025 in Insights into Imaging
Verified
Journal Article
Open access
BKBurak Kocak
Burak Kocak
Angela AmmirabileAngela Ammirabile
Angela Ammirabile
IAIlaria Ambrosini
Ilaria Ambrosini
TDTugba Akinci D'Antonoli
Tugba Akinci D'Antonoli
ABAlessandra Borgheresi
Alessandra Borgheresi
Renato CuocoloRenato Cuocolo
Renato Cuocolo
Radiomics research has been hindered by inconsistent and often poor methodological quality, limiting its potential for clinical translation. To address this challenge, the METhodological RadiomICs Score (METRICS) was recently introduced as a tool for systematically assessing study rigor. However, its effective application requires clearer guidance. The METRICS-E3 (Explanation and Elaboration with Examples) resource was developed by the European Society of Medical Imaging Informatics—Radiomics Auditing Group in response. This international initiative provides comprehensive support for users by offering detailed rationales, interpretive guidance, scoring recommendations, and illustrative examples for each METRICS item and condition. Each criterion includes positive examples from peer-reviewed, open-access studies and hypothetical negative examples. In total, the finalized METRICS-E3 includes over 200 examples. The complete resource is publicly available through an interactive website. Critical relevance statement: METRICS-E3 offers deeper insights into each METRICS item and condition, providing concrete examples with accompanying commentary and recommendations to enhance the evaluation of methodological quality in radiomics research. Key Points: As a complementary initiative to METRICS, METRICS-E3 is intended to support stakeholders in evaluating the methodological aspects of radiomics studies. In METRICS-E3, each METRICS item and condition is supplemented with interpretive guidance, positive literature-based examples, hypothetical negative examples, and scoring recommendations. The complete METRICS-E3 explanation and elaboration resource is accessible at its interactive website. Graphical