Shuang Wang

Mrs. Shuang Wang


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KLKewu Li
Kewu Li
SWShuang Wang
Shuang Wang
ZWZhibin Wang
Zhibin Wang
To obtain highly sensitive, accurate, fast, and repeatable measurements of waveplate parameters over an entire clear aperture, a novel measurement method using dual differential frequency photoelastic modulations is proposed. Simple polarimetry is conducted based on two photoelastic modulators, which operate at different frequencies. The fast-axis azimuth and retardance parameters of the waveplate are loaded into the modulation signals. Employing digital phase-locked technology, the fundamental and differential frequency harmonic terms are extracted, and then the two parameters of the waveplate are demodulated. The principle is analyzed, and the measurement system is built for verification experiments. The experimental results reveal that the two parameters of the waveplate are simultaneously measured over the entire clear aperture. The standard deviations of the fast-axis azimuth and retardance are 0.02° and 0.03 nm, respectively, and the maximum relative deviations of the fast-axis azimuth and retardance are 0.6% and 0.06%, respectively. The single-point data measurement time is only 200 ms. The proposed method exhibits high precision and speed, and provides an effective quality inspection and calibration method for waveplates.

1 January 2022 in Journal of Applied Optics
Verified
Journal Article
Closed access
PDF file
KLKewu Li
Kewu Li
SWShuang Wang
Shuang Wang
中北中北大学电气与控制工程学院,山西太原030051
中北大学电气与控制工程学院,山西太原030051
山西山西省光电信息与仪器工程技术研究中心,山西太原030051
山西省光电信息与仪器工程技术研究中心,山西太原030051
中北中北大学前沿交叉科学研究院,山西太原030051
中北大学前沿交叉科学研究院,山西太原030051
In order to achieve the accurate calibration and long-time stable operation for photoelastic modulator (PEM), a calibration and control scheme of phase retardation amplitude which using feedback optical path was established, and the spatial distribution of phase retardation amplitude on the PEM optical aperture was theoretically calculated and simulated. An integrated calibration feedback optical path was designed deviating from the center of PEM. Combined with the phase retardation amplitude calibration method using the ratio of harmonic terms, the digital phase lock technology was used to simultaneously extract the harmonic terms of the modulated light intensity signals from the feedback optical path, and then the phase retardation amplitude of PEM was solved. According to the proposed scheme, the PEM physical object was processed, and the calibration experiment and stability control experiment were both carried out. The experimental results show that, the relative deviation between the calibration value and measured value of phase retardation amplitude of PEM center does not exceed 0.22%. With the use of feedback optical path to control the PEM about 100 minutes, the standard deviation of PEM phase retardation amplitude is 0.001 8 rad and the maximum deviation is lower than 0.42%, which realizes the accurate and real-time calibration of PEM phase retardation amplitude and the long-time stable control of PEM is also verified.

10 August 2024 in Sensors
Verified
Journal Article
Open access
PDF file
SWShuang Wang
Shuang Wang
XHXie Han
Xie Han
KLKewu Li
Kewu Li
A snapshot multi-wavelength birefringence imaging measurement method was proposed in this study. The RGB-LEDs at wavelengths 463 nm, 533 nm, and 629 nm were illuminated with circularly polarized light after passing through a circular polarizer. The transmitted light through the birefringent sample was captured by a color polarization camera. A single imaging process captured light intensity in four polarization directions (0°, 45°, 90°, and 135°) for each of the three RGB spectral wavelength channels, and subsequently measured the first three elements of Stokes vectors (S0, S1, and S2) after the sample. The birefringence retardance and fast-axis azimuthal angle were determined simultaneously. An experimental setup was constructed, and polarization response matrices were calibrated for each spectral wavelength channel to ensure the accurate detection of Stokes vectors. A polymer true zero-order quarter-wave plate was employed to validate measurement accuracy and repeatability. Additionally, stress-induced birefringence in a PMMA arch-shaped workpiece was measured both before and after the application of force. Experimental results revealed that the repeatability of birefringence retardance and fast-axis azimuthal angle was better than 0.67 nm and 0.08°, respectively. This approach enables multispectral wavelength, high-speed, high-precision, and high-repeatability birefringence imaging measurements through a single imaging session.

26 November 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SWShuang Wang
Shuang Wang
KLKewu Li
Kewu Li
XHXie Han
Xie Han
ZWZhibin Wang
Zhibin Wang
To develop fast and integrated spectrometry, we present a new method of compressed sensing spectrometry based on electro-optical transmittance coding. A LiNbO3 electro-optic modulator was applied to a directly compressed measurement code in the spectral dimension. Subsequently, a sequential forward floating selection algorithm was employed to select the coding measurement matrix, and sparsity adaptive matching pursuit was used as a solver algorithm. The principle was analyzed, and the measurement system was built for verification experiments. The experimental results reveal that the spectral reconstruction relative error is in the order of 10−2, and the full width at half maximum of the spectral measurement is as high as 1.2 nm. The spectral resolution can reach approximately 0.4 nm in the visible light band range (0.38–0.78 μm) with 1024 spectral channels. The compressed ratio of the compressed sensing spectrometry is up to 1:29. Furthermore, the spectral signal measurement time is only 0.25 ms. The study demonstrates a novel method, which exhibits high precision, speed, high compressed ratio and hyperspectral resolution.

1 January 2026 in Acta Physica Sinica
Verified
Journal Article
Open access
PDF file
KLKewu Li
Kewu Li
BLBo Liu
Bo Liu
XWXiaolan Wu
Xiaolan Wu
YDYe Dong
Ye Dong
SWShuang Wang
Shuang Wang
准连续域束缚态(quasi-bound states in the continuum,q-BIC)超表面具有高Q值和强局域场,能够实现共振波长、振幅、相位及偏振等有效操控,是实现高性能传感和光电子器件的理想平台。现有q-BIC偏振调控多依赖旋转纳米结构单元或改变结构高度,加工复杂且灵活性不足,限制了其在偏振维度的多功能集成。本研究提出了一种在纳米结构单元内部引入孔洞微扰的策略,直接调控q-BIC的本征偏振模式。研究通过耦合模理论和多极子分解解析了微扰改变结构单元局域介电常数及电偶极矩分布,从而影响本征偏振方向的物理机制。设计并制备了基于a-Si纳米柱二聚体的系列超表面样品,通过改变孔洞数量及排布引入微扰。仿真与实验结果表明,随着孔洞数量增加,q-BIC的本征偏振方向能从初始0°发生顺时针偏转,同时共振波长产生蓝移。实验测得的偏振响应与仿真结果一致。本文研究提供了一种简易、灵活的q-BIC偏振操控手段,为发展紧凑型偏振转换、偏振测量与信息处理超表面开辟了新途径。