Kewu Li

Prof. Dr. Kewu Li

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2017 in Sensors
Verified
Journal Article
Open access
PDF file
KLKewu Li
Kewu Li
SWShuang Wang
Shuang Wang
LWLiming Wang
Liming Wang
HYHui Yu
Hui Yu
TYTianfu Yang
Tianfu Yang
ZWZhibin Wang
Zhibin Wang
In this work, a biosensing method based on in situ, fast, and sensitive measurements of ellipsometric parameters (Ψ, ∆) is proposed. Bare silicon wafer substrate is functionalized and used to bind biomolecules in the solution. Coupled with a 45° dual-drive symmetric photoelastic modulator-based ellipsometry, the parameters Ψ and ∆ of biolayer arising due to biomolecular interactions are determined directly, and the refractive index (RI) of the solution and the effective thickness and surface mass density of the biolayer for various interaction time can be further monitored simultaneously. To illustrate the performance of the biosensing method, immunosensing for immunoglobulin G (IgG) was taken as a case study. The experiment results show that the biosensor response of the limit of detection for IgG is 15 ng/mL, and the data collection time is in milliseconds. Moreover, the method demonstrates a good specificity. Such technique is a promising candidate in developing a novel sensor which can realize fast and sensitive, label-free, easy operation, and cost-effective biosensing.

2 March 2017 in Optics Express
Verified
Journal Article
Open access
PDF file
KLKewu Li
Kewu Li
ZRZhang Rui
Zhang Rui
JNJing Ning
Jing Ning
CYChen Youhua
Chen Youhua
ZMZhang Minjuan
Zhang Minjuan
ZWZhibin Wang
Zhibin Wang
The fast and full range measurements of ellipsometric parameters ψ and Δ using a 45° dual-drive symmetric photoelastic modulator (PEM) are proposed. The PEM operates in a pure traveling modulation mode with a constant retardation magnitude and the modulation axis performing circular motion. A field programmable gate array is used to control the PEM and fulfill the data processing. The parameters sin 2ψ sinΔ, sin 2ψ cosΔ, and sin 2ψ can be measured simultaneously, providing accurate measurements of ψ and Δ over the full range. The experimental results show that the repeatability and sensitivity of this system are at 10-3°, and the data acquisition rate is 1 ms/point.

19 January 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SWShuang Wang
Shuang Wang
XHXie Han
Xie Han
YWYaning Wang
Yaning Wang
KLKewu Li
Kewu Li
Recently, ellipsometry and polarization imaging using photoelastic modulators (PEMs) have been applied to a wide spectral range, from vacuum ultraviolet to the mid-infrared wavelengths. To ensure high accuracy polarization performance, the accurate calibration of the retardation of PEM is crucial. In this report, the dispersion of the retardation of the PEM is studied. According to the operational principle of PEM, their retardation can be separated into independent dispersion and driving terms. The effect attributed to the dispersion on PEM retardation calibration is experimentally explored. These experiments indicate that the dispersion term can be defined in advance using the refractive index of the photoelastic crystal under incident light, and that the driving term is directly proportional to the amplitude of the driving voltage. The calibration method for the retardation amplitude of the PEM, which considers dispersion, is also demonstrated. The results show that the relative deviation between the calibration and actual measurement values of PEM retardation amplitude are less than 1%. This study presents an accurate way to calibrate the PEM retardation and supports the application of PEMs in a wide range of wavelengths.

1 April 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KLKewu Li
Kewu Li
SWShuang Wang
Shuang Wang
ZWZhibin Wang
Zhibin Wang
To obtain highly sensitive, accurate, fast, and repeatable measurements of waveplate parameters over an entire clear aperture, a novel measurement method using dual differential frequency photoelastic modulations is proposed. Simple polarimetry is conducted based on two photoelastic modulators, which operate at different frequencies. The fast-axis azimuth and retardance parameters of the waveplate are loaded into the modulation signals. Employing digital phase-locked technology, the fundamental and differential frequency harmonic terms are extracted, and then the two parameters of the waveplate are demodulated. The principle is analyzed, and the measurement system is built for verification experiments. The experimental results reveal that the two parameters of the waveplate are simultaneously measured over the entire clear aperture. The standard deviations of the fast-axis azimuth and retardance are 0.02° and 0.03 nm, respectively, and the maximum relative deviations of the fast-axis azimuth and retardance are 0.6% and 0.06%, respectively. The single-point data measurement time is only 200 ms. The proposed method exhibits high precision and speed, and provides an effective quality inspection and calibration method for waveplates.

4 January 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KLKewu Li
Kewu Li
SWShuang Wang
Shuang Wang
XHXie Han
Xie Han
ZWZhibin Wang
Zhibin Wang
A novel method for determining the electro-optic (EO) coefficient γ 22 of lithium niobate and its dispersion using photoelastic modulation is presented. A spectroscopic polarimetry was constructed with the photoelastic modulator (PEM), and a monochromator was selected to automatically scan the wavelength of a light source. Phase retardation induced by an EO sample was loaded into the modulation signals to demodulate the EO coefficients. The PEM and data processing were controlled in the same field programmable gate array (FPGA), and the DC and harmonic terms were extracted simultaneously by employing digital phase-locked technology. An experimental system was built to analyze the principle of this scheme in detail. After the modulation phase retardation amplitude of the PEM was precisely calibrated, the EO coefficient γ 22 of a Y-cut lithium niobate crystal plate was measured in the spectral range from 0.42 to 0.8 µm. The experimental results demonstrated that the measurement sensitivity of the system was 1.1 × 10 − 14   m / V for a sampling time of 198.9 ms. Plotting the measured results against the light wavelength, the dispersion of the EO coefficients was obtained similar to the Cauchy dispersion formula γ 22 = 5.31   ×   10 − 12 + 4.071   ×   10 − 13 λ 2 + 7.184   ×   10 − 14 λ 4 in the visible light range. This method is suitable for studying dispersion of the EO coefficients of crystals as well as of thin films and two-dimensional materials.

23 May 2019 in Applied Optics
Verified
Journal Article
Closed access
PDF file
SWShuang Wang
Shuang Wang
ZWZhibin Wang
Zhibin Wang
XHXie Han
Xie Han
KLKewu Li
Kewu Li
To realize high-speed, accurate, and sensitive measurement of electro-optic (EO) coefficients, a novel measurement method using photoelastic modulation is proposed. A simple polarimetry is constructed based on the photoelastic modulator, and the phase difference induced by the EO sample is loaded in the modulation signals. Employing the digital phase-locked technology, the DC, first, and second harmonic terms are extracted, respectively, and then the EO coefficients are demodulated. The experimental system is set up to analyze the principle of this scheme in detail. A Y-cut LiNbO3 crystal plate is selected as the sample, and the EO coefficient γ22 is studied under different applied DC voltages. The results demonstrate that the measurement accuracy and sensitivity of the system are 0.22% and 1.5×10−14 m/V, respectively, when the sampling time is set as 198.9 ms. The measuring rate can be further enhanced, if the appropriate reduction of the measurement sensitivity is allowed.