Christoph Hahn

Christoph Hahn

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2019 in Macromolecules
Verified
Journal Article
Closed access
JBJan Blankenburg
Jan Blankenburg
KMKamil Maciol
Kamil Maciol
CHChristoph Hahn
Christoph Hahn
HFHolger Frey
Holger Frey

10 May 2022 in Physical Review A
Verified
Journal Article
Open access
PDF file
BZBinghui Zhu
Binghui Zhu
AGAlexandre Gumberidze
Alexandre Gumberidze
TOTobias Over
Tobias Over
GWG. Weber
G. Weber
ZAZ. Andelkovic
Z. Andelkovic
TSThomas Stöhlker
Thomas Stöhlker
For decelerated bare lead ions at a low beam energy of 10 MeV/u, the x-ray emission associated with radiative recombination (RR) at threshold energies has been studied at the electron cooler of CRYRING@ESR at GSI, Darmstadt. In our experiment, we observed the full x-ray emission pattern by utilizing dedicated x-ray detection chambers installed at 0∘ and 180∘ observation geometry. Most remarkably, no line distortion effects due to delayed emission are present in the well-defined x-ray spectra, spanning a wide range of x-ray energies (from about 5 to 100 keV), which enables us to identify fine-structure resolved Lyman, Balmer, and Paschen x-ray lines along with the RR transitions into the K, L, and M shells of the ions. For comparison with theory, an elaborate theoretical model is established taking into account the initial population distribution via RR for all atomic levels up to Rydberg states with principal quantum number n=165 in combination with time-dependent feeding transitions. Within the statistical accuracy, the experimental data are in very good agreement with the results of rigorous relativistic predictions. Most notably, this comparison sheds light on the contribution of prompt and delayed x-ray emission (up to 70 ns) to the observed x-ray spectra, originating in particular from yrast transitions into inner shells.

30 March 2024 in European Polymer Journal
Verified
Journal Article
Open access
CHChristoph Hahn
Christoph Hahn
SBSebastian Becker
Sebastian Becker
AMAxel H.E. Müller
Axel H.E. Müller
HFHolger Frey
Holger Frey

9 January 2023 in Physical Review A
Verified
Journal Article
Open access
PDF file
WMWilko Middents
Wilko Middents
GWGünter Weber
Günter Weber
AGAlexandre Gumberidze
Alexandre Gumberidze
CHChristoph Hahn
Christoph Hahn
TKThomas Krings
Thomas Krings
TSThomas Stöhlker
Thomas Stöhlker
We perform a study on Rayleigh scattering of highly linearly polarized hard x rays on a thin Au foil target. In the study the angular distribution of the scattered radiation is analyzed in a relativistic regime both within and out of the plane of polarization of the incident beam. Within this experiment we scatter a synchrotron beam with a photon energy of 175 keV on a high-Z target foil, namely, gold. Our findings correlate well with state-of-the-art calculations of the scattering process performed in the framework of quantum electrodynamics and may have considerable impact on future experiments regarding a polarization-resolved analysis of Delbrück scattering. Furthermore, we show that the angular distribution of Rayleigh scattering can be used for a highly sensitive determination of the degree and orientation of the linear polarization of the incident hard-x-ray beam, if we rely on the theoretical framework.

1 April 2016 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
CHChristoph Hahn
Christoph Hahn
GWG. Weber
G. Weber
RMR. Märtin
R. Märtin
SHS. Höfer
S. Höfer
TKT. Kämpfer
T. Kämpfer
TSTh. Stöhlker
Th. Stöhlker
Single-photon spectroscopy of pulsed, high-intensity sources of hard X-rays — such as laser-generated plasmas — is often hampered by the pileup of several photons absorbed by the unsegmented, large-volume sensors routinely used for the detection of high-energy radiation. Detectors based on the Timepix chip, with a segmentation pitch of 55 μm and the possibility to be equipped with high-Z sensor chips, constitute an attractive alternative to commonly used passive solutions such as image plates. In this report, we present energy calibration and characterization measurements of such devices. The achievable energy resolution is comparable to that of scintillators for γ spectroscopy. Moreover, we also introduce a simple two-detector Compton polarimeter setup with a polarimeter quality of (98 ± 1)%. Finally, a proof-of-principle polarimetry experiment is discussed, where we studied the linear polarization of bremsstrahlung emitted by a laser-driven plasma and found an indication of the X-ray polarization direction depending on the polarization state of the incident laser pulse.

31 December 2022 in Atoms
Verified
Journal Article
Open access
PDF file
PPPhilip Pfäfflein
Philip Pfäfflein
GWGünter Weber
Günter Weber
SASteffen Allgeier
Steffen Allgeier
SBSonja Bernitt
Sonja Bernitt
AFAndreas Fleischmann
Andreas Fleischmann
TSThomas Stöhlker
Thomas Stöhlker
In this report, we compare two filter algorithms for extracting timing information using novel metallic magnetic calorimeter detectors, applied to the precision X-ray spectroscopy of highly charged ions in a storage ring. Accurate timing information is crucial when exploiting coincidence conditions for background suppression to obtain clean spectra. For X-rays emitted by charge-changing interactions between ions and a target, this is a well-established technique when relying on conventional semiconductor detectors that offer a good temporal resolution. However, until recently, such a coincidence scheme had never been realized with metallic magnetic calorimeters, which typically feature much longer signal rise times. In this report, we present optimized timing filter algorithms for this type of detector. Their application to experimental data recently obtained at the electron cooler of CRYRING@ESR at GSI, Darmstadt is discussed.