Haijin Li

Dr. Haijin Li

Beijing Institute of Spacecraft System Engineering, Beijing, China
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 September 2024 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
KCKaixin Cui
Kaixin Cui
TGTianran Gao
Tianran Gao
DSDawei Shi
Dawei Shi
HFHanjing Fu
Hanjing Fu
ZLZhigang Liu
Zhigang Liu
HLHaijin Li
Haijin Li
In this work, an event-triggered learning problem for state-of-charge (SOC) estimation of long-term spacecraft li-ion batteries with system aging and disturbances is investigated based on a physics-informed long short-term memory (PI-LSTM) network. An equivalent circuit model and a pretrained Gaussian process regression model are integrated into a long short-term memory (LSTM) network, which is trained and updated quickly with limited transmission data. By considering noisy data and physical constraints simultaneously, the PI-LSTM approach provides interpretable dynamic models for the long-term battery SOC estimation. Then, an unscented Kalman filter is proposed to estimate the SOC performance. By using weighted average voltage prediction errors, an event-triggering condition is established to guarantee the estimation performance with a reduced signal transmission rate. The effectiveness of the proposed approach is validated through experiments on a real spacecraft Li-ion battery platform, which achieves the SOC estimation error of less than 2%, and the maximum voltage prediction error is reduced by 61% after updating the PI-LSTM model.

18 September 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
HLHaijin Li
Haijin Li
MCMin Chen
Min Chen
BYBoping Yang
Boping Yang
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
DXDehong Xu
Dehong Xu
The high-surety power supply system, Super Uninterruptable Power Supply (Super-UPS), is an evolution of the traditional UPS. It consists of multiple sources, multiple energy storages and redundant power converters to improve the reliability of the power supply system significantly. In this paper, a fast fault protection scheme based on direction of fault current without the assistance of communication for Super-UPS is presented. It achieves fast and selective fault detection and ensures the uninterruptible load power when short-circuit faults occur. The directional fault current detection and the coordination between the circuit breakers and converters are investigated. The protection threshold setting are also discussed. In addition, an improved fault current measurement method, which can suppress the influence of stray inductance of the solid state circuit breaker, is presented to guarantee an accurate operation of the protection scheme for rapidly rising fault current. Finally, the proposed protection scheme and the improved fault current measurement method for Super-UPS are verified by experiments.

1 June 2015
Verified
Conference Paper
Closed access
KSKeyan Shi
Keyan Shi
HLHaijin Li
Haijin Li
CHChangsheng Hu
Changsheng Hu
DXDehong Xu
Dehong Xu
The dramatic loss caused by the power blackout in some industrial applications proposes the requirement for an extremely high reliability uninterruptible power supply (UPS). This paper introduces the concept of super uninterruptible power supply (Super UPS). Multiple energy sources are used to obtain a high reliability, long backup time, high surety UPS system. Classifications for energy sources, power conversion stage and power distribution bus line are established to simplify the power conversion architectures. A generic method to classify the architectures for multiple energy source system is presented. Then a system reliability evaluation method based on different architectures is used to analyze the characteristics of different types of topology. Redundant power conversion stage design to enhance the system reliability is discussed. Finally, a high reliability super UPS architecture is proposed.

21 August 2023 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
KCKaixin Cui
Kaixin Cui
DSDawei Shi
Dawei Shi
ZLZhigang Liu
Zhigang Liu
DYDong Yang
Dong Yang
HLHaijin Li
Haijin Li
QDQing Du
Qing Du
Performance monitoring is essential for the safety maintenance and health management of networked systems. In this work, we propose a behavioral-based monitoring approach for networked systems, which directly utilizes input and output measurements without parametric identification. A regularized cost function and system dynamic constraints are designed to reduce the disturbance of system nonlinearity and noise, which can be used to predict future trajectories of networked systems. Missing data during the long-distance transmission are also estimated through the fundamental lemma in behavioral system theory. Then, a statistical inference strategy based on the difference between the predicted trajectories and the real measurement trajectories is introduced to detect system faults. The effectiveness of the proposed approach is illustrated through experimental applications to the spacecraft Li-ion battery health management, which includes charging and discharging trajectory prediction, missing data estimation, and voltage sensor and overdischarge fault detection.

3 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
HLHaijin Li
Haijin Li
YGYu Gu
Yu Gu
XZXiaofeng Zhang
Xiaofeng Zhang
ZLZhigang Liu
Zhigang Liu
Longlong ZhangLonglong Zhang
Longlong Zhang
YZYi Zeng
Yi Zeng
With the development of space exploration, high-power and high-voltage power systems are essential for future spacecraft applications. Because of the effects of space radiation such as single event burnout (SEB), the rated voltage of power devices in converters for a spacecraft power system is limited to a level much lower than that for traditional ground applications. Thus, multi-level DC/DC converters are good choices for high-voltage applications in spacecraft. In this paper, a fault-tolerant strategy is proposed for a three-level flying capacitor DC/DC converter to increase the reliability with minimal cost. There is no extra hardware needed for the proposed strategy; the fault tolerance of the converter is only achieved by changing the software control strategy. A stage analysis of the proposed strategy is provided in detail for different fault locations and ratios between the input and output voltage. Finally, a simulation model and prototype are built to verify the effectiveness of the proposed strategy.

3 October 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
TGTianran Gao
Tianran Gao
KCKaixin Cui
Kaixin Cui
ZLZhigang Liu
Zhigang Liu
HLHaijin Li
Haijin Li
DSDawei Shi
Dawei Shi
In this work, the problem of state-of-charge (SOC) estimation for batteries with different chemical properties and different operating conditions is investigated based on a physics-enhanced bidirectional long short-term memory (PEBi-LSTM) network. The first physical layer of the PEBi-LSTM network learns the open-circuit and polarization voltages of batteries under various operating conditions by identifying a first-order RC equivalent circuit model, simplifying the mapping between measurement variables and SOC. Then, a two-stage transfer strategy is proposed to estimate the SOC of different lithium batteries. In the first stage, limited labeled data are used to fine-tune the Bi-LSTM layers to extract the effective features of new batteries and ensure model stability. Next, the mapping relationships in the fully connected layers are optimized by the adversarial transfer method, which reduces the data distribution differences between new and original batteries. The effectiveness of the PEBi-LSTM algorithm is verified by comparative experiments on the public dataset. In addition, experiments on a real spacecraft lithium battery platform show that the designed two-stage transfer method reduces errors at -20°C by 74.25% and 45.6% compared with the fine-tuning transfer method and the adversarial transfer method, respectively.