Yu-Wen Lin

Prof. Yu-Wen Lin

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2009 in Annals of Occupational Hygiene
Verified
Journal Article
Open access
PDF file
HLHsiao-Shu Lee
Hsiao-Shu Lee
Yu-Wen LinYu-Wen Lin
Yu-Wen Lin
Skin irritation and contact allergies are skin disorders common to hairdressers. The predominant oxidative hair dye components, such as p-phenylenediamine (PPD) and aminophenol isomers, can cause contact dermatitis. Use of protective gloves can prevent dermal contact with skin irritants. This study investigates the permeation behaviors of p-aminophenol (PAP), m-aminophenol (MAP), o-aminophenol (OAP) and PPD in single and mixed challenge solutions with disposable natural rubber latex (NRL) gloves, disposable polyvinylchloride (PVC) gloves and neoprene (NP) gloves. The challenge solutions were 4% PPD (w/v), 3% OAP (w/v), 2% PAP (w/v) and 2% MAP (w/v) in ethanol or 12% hydrogen peroxide solutions. The cocktail solutions of the four chemicals were also tested. An American Society for Testing and Materials type permeation cell, ethanol liquid collection and gas chromatography–flame ionization detection of samples taken from the collection medium every 10 min facilitated determination of breakthrough times (BTs), cumulative permeated masses and steady-state permeation rates (SSPRs). Experiments were 4 h long for the NRL and PVC gloves and 8 h for NP gloves. No chemicals tested broke through the NP gloves when exposed for 8 h. In the ethanol solution, PPD and OAP started breaking through the PVC gloves at 40 min. The SSPRs of PVC gloves were higher than those for NRL gloves in all challenge conditions for both single chemicals and mixtures. No tested chemicals in hydrogen peroxide solutions permeated the gloves during the 4-h tests. The chemical composition of the challenge solution was a main effecter of BTs and SSPRs for the NRL glove. For disposable PVC gloves, the main factors of BTs were molecular size [molar volume (MV)] and polarity (logKow), and the primary factors of SSPRs were concentration, MV and logKow. In conclusion, disposable NRL gloves and disposable PVC gloves should not be used repeatedly for handling the hair dye products. Hydrogen peroxide did not accelerate chemical breakthrough. The compositions of the challenge solutions and physical and chemical properties (MV and logKow) affected permeation behaviors for different gloves.

13 October 2022 in Safety and Health at Work
Verified
Journal Article
Open access
YLYu-Cheng Lin
Yu-Cheng Lin
Yu-Wen LinYu-Wen Lin
Yu-Wen Lin
The present study aimed to digitally evaluate the risk of overwork-related adverse effects (OrAEs) among employees from various occupational categories in Taiwan. Anonymous data of employees from seven companies/factories providing occupational health services were analyzed. The studied population comprised 5505 employees, and the data analyzed included employment duration, working hours, shift work schedules, and health checkup results. The risk for OrAEs was assessed by an index, Karo index (0-4, the larger the value, the higher the risk for OrAEs) obtained using a risk matrix made up of cardiocerebral and occupational risk factors. Karo index values of 3 and 4 were categorized as at high risk for OrAEs (h-OrAEs). The 5505 employees had an average employment duration of 8.5 years and a mean age of 39.4 years. The prevalence rates for h-OrAEs of the seven companies/factories ranged from 3.9% to 34.2%. There were significant differences in prevalence rates for h-OrAEs between employees of retail stores and high-tech manufacturing factories. Multivariate analysis results indicated that workers of high-tech manufacturing factories had significantly higher risk for h-OrAEs compared with retail store workers. In terms of satisfying health risk management and legal requirements in Taiwan, the newly issued Karo index, which covers a wide range of occupational risk factors, can serve as an assessment and a warning tool for managing the risk of OrAEs in workplaces. To reduce risks for h-OrAEs, active and prudent control of cerebrocardiovascular risks and working hours is recommended.

4 April 2024 in Safety and Health at Work
Verified
Journal Article
Open access
LLLi-Wen Liu
Li-Wen Liu
CCCHENG-PING CHANG
CHENG-PING CHANG
Yu-Wen LinYu-Wen Lin
Yu-Wen Lin
WCWei-Ming Chu
Wei-Ming Chu
Glove reuse poses risks, as chemicals can persist even after cleaning. Decontamination methods like thermal aeration, recommended by US OSHA, vary in effectiveness. Some studies show promising results, while others emphasize the importance of considering both permeation and tensile strength changes. This research advocates for informed glove reuse, emphasizing optimal thermal aeration temperatures and providing evidence to guide users in maintaining protection efficiency. The investigation evaluated Neoprene and Nitrile gloves (22 mils). Permeation tests with toluene and acetone adhered to American Society for Testing Materials (ASTM) F739 standards. Decontamination optimization involved aeration at various temperatures. The experiment proceeded with a maximum of 22 re-exposure cycles. Tensile strength and elongation were assessed following ASTM D 412 protocols. Breakthrough time differences were statistically analyzed using t-test and ANOVA. At room temperature, glove residuals decreased, and standardized breakthrough time (SBT)2 was significantly lower than SBT1, indicating reduced protection. Higher temperature decontamination accelerated residual removal, with ΔSBT (SBT2/SBT1) exceeding 100%, signifying restored protection. Tensile tests showed stable neoprene properties postdecontamination. Results underscore thermal aeration's efficacy for gloves reuse, emphasizing temperature's pivotal role. Findings recommend meticulous management strategies, especially post-breakthrough, to uphold glove-protective performance. Thermal aeration at 100°C for 1 hour proves effective, restoring protection without compromising glove strength. The study, covering twenty cycles, suggests safe glove reuse with proper decontamination, reducing costs significantly. However, limitations in chemical-glove combinations and exclusive focus on specific gloves caution against broad generalization. The absence of regulatory directives on glove reuse highlight the importance of informed selection and rigorous decontamination validation for workplace safety practices.

12 January 2022 in Industrial Health
Verified
Journal Article
Open access
PDF file
MTMila Tejamaya
Mila Tejamaya
WPWantanee Phanprsit
Wantanee Phanprsit
JKJiwon Kim
Jiwon Kim
FTFeng-jen Tsai
Feng-jen Tsai
GMGo Muto
Go Muto
DPDonguk Park
Donguk Park
The types of workplaces and occupations with coronavirus 2019 (COVID-19) clusters vary between countries and periods. We aimed to characterize major occupational groups with mass outbreaks of COVID-19 infections in several Asia-Pacific countries. Data on the major occupations or workplaces reporting COVID-19 cases in workplaces from January 2020 to July 2021 was collected from industrial hygiene professionals in nine countries. The proportion of workers accounted for 39.1 to 56.6% of the population in each country. The number of workers covered in the national statistics varies among nations based on their definition of a worker. None of the countries examined here have systematically collected occupational data on COVID-19 illnesses and deaths classified by type of industry, occupation, or job. Most countries experienced COVID-19 clusters among health and social care workers (HSCW) in hospitals or long-term care facilities. The types of occupations or workplaces with virus clusters in some participating countries included prisons, call centers, workplaces employing immigrants, garment facilities, grocery stores, and the military, which differed among countries, except for a few common occupations such as HSCW and those populated by immigrants. Further study is necessary in order to seek ways to control infection risks, including revisions to industrial-health-related laws.

XSXiaoHan Shen
XiaoHan Shen
YCYung-Yueh Chang
Yung-Yueh Chang
RPRong-Qi Pham
Rong-Qi Pham
WCWei-An Chen
Wei-An Chen
FLFang-Yu Li
Fang-Yu Li
Yu-Wen LinYu-Wen Lin
Yu-Wen Lin
Lung cancer is the leading cause of cancer deaths worldwide, and squamous cell carcinoma (SQC) is Taiwan’s second most common lung carcinoma histotype. This study aimed to investigate changes in the long-term trend of the SQC incidence rate in Taiwan. SQC cases between 1985 and 2019 were adopted from Taiwan‘s Cancer Registry System; the age-adjusted incidence rate was calculated using the World Standard Population in 2000. The long-term trends of the age, period, and birth cohort effect of SQC incidence rates were estimated using the SEER Age-Period-Cohort Web Tool. The results revealed that the incidence of lung carcinoma in Taiwan increased, while the incidence of SQC exhibited a slight decrease during this study period. The age rate ratio (ARR) of the incidence rate in men declined gradually, and the period effect changed more slowly for women than men. The cohort effect formed a bimodal curve. The annual percentage change results for women indicated that the ARR decreased from 1.652 (95% confidence interval (CI): 1.422, 1.9192) at 30 to 34 years to 0.559 (95% CI: 0.4988, 0.6265) at 75 to 79 years; the period effect decreased from 1.2204 (95% CI: 1.1148, 1.336) in 1995 to 1999 to 0.608 (95% CI: 0.5515, 0.6704) in 2015 to 2019, with a greater decline in the later period. The cohort effect was unimodal, with the SQC risk value peaking in the 1915 birth cohort and exhibiting a steady decline thereafter. The results of this study suggest that a decrease in the smoking rate may be the reason for the decline in the incidence of SQC, and we observed a similar trend between SQC and the smoking rate in men.

1 August 2014 in Journal of the Formosan Medical Association
Verified
Journal Article
Closed access
GWGwo-Hwa Wan
Gwo-Hwa Wan
DYDah-Chin Yan
Dah-Chin Yan
HTHui-Yun Tseng
Hui-Yun Tseng
JLJian Tao Lee
Jian Tao Lee
Yu-Wen LinYu-Wen Lin
Yu-Wen Lin