Antonio Moramarco

Prof. Antonio Moramarco

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 November 2023 in Cornea
Verified
Journal Article
Open access
Luigi FontanaLuigi Fontana
Luigi Fontana
NGNatallie di Geronimo
Natallie di Geronimo
MCMichela Cennamo
Michela Cennamo
RMRita Mencucci
Rita Mencucci
PVPiera Versura
Piera Versura
AMAntonio Moramarco
Antonio Moramarco
Purpose: The purpose of this study was to report the outcomes of a novel artificial endothelial replacement membrane implant for treating corneal edema after failed repeat endothelial keratoplasty (EK). Design: This was a retrospective interventional case series. Methods: Patients with chronic corneal edema underwent removal of the EK graft and implantation of an artificial endothelial replacement membrane (EndoArt, EyeYon Medical, Israel) several months after 2 or more Descemet stripping endothelial keratoplasty procedures. The implant was secured to the posterior corneal surface using an air–gas bubble. Outcome measures included corrected distance visual acuity (logMAR), central corneal thickness, device-related complications, and ocular discomfort. Results: Five eyes of 5 patients underwent EndoArt implantation. Six months after surgery, the synthetic endothelial replacement membrane was well-centered and adherent to the posterior corneal surface, with improvement in central corneal transparency in all patients. Corrected distance visual acuity increased from mean 1.26 ± 0.25 (logMAR) preoperatively to 0.74 ± 0.44 (logMAR) postoperatively (P = 0.06). Central corneal thickness significantly decreased from a mean of 805 ± 135 μm (excluding the EK graft) preoperatively to 588 ± 60 μm (excluding the EndoArt) postoperatively (P = 0.015). No severe device-related complications developed after surgery, although most patients required more than 1 air–gas bubble injection to achieve complete implant adhesion. All patients experienced preoperative reduction in subjective ocular pain. Conclusions: Synthetic endothelial replacement membrane implantation improves central corneal transparency and visual acuity in patients with failed EK and guarded prognosis for repeat keratoplasty. No significant implant-related adverse events occurred after surgery.

Verified
Journal Article
Open access
PDF file
AMAntonio Moramarco
Antonio Moramarco
LGLorenzo Gardini
Lorenzo Gardini
DIDanilo Iannetta
Danilo Iannetta
PVPiera Versura
Piera Versura
LFLuigi Fontana
Luigi Fontana
BACKGROUND: Corneal transplantation in keratoconus (KC) patients is generally considered to be successful with a high grade of patient satisfaction. Long-term studies suggest a 6% to 11% probability of KC recurrence manifested by keratometric instability and progressive corneal ectasia. METHODS: We propose to review the frequency, risk factors for the development, and the surgical options for the correction of high irregular astigmatism due to late graft ectasia following penetrating keratoplasty (PK). RESULTS: Post-keratoplasty ectasia is characterized by increasing corneal steepening with myopic shift and high irregular astigmatism, developing years or decades after PK, mostly occurring in KC patients. Contact lenses may adequately improve the visual acuity; however, because these patients are often elderly and intolerant to hard contact lenses, ultimately a surgical correction is proposed to the patient. Compressive suture and corneal wedge resection may improve corneal astigmatism, but the outcomes are unpredictable and often temporary. For this reason, a larger PK graft is often proposed for surgical rehabilitation with the consequence of removing more of the recipient’s healthy endothelium and exposing the patient to a renewed immunogenic stimulus and short-term graft failure for endothelial decompensation. More recently, lamellar keratoplasty using various techniques has been proposed as an alternative to PK in order to maximize the visual outcomes and minimize the complications. CONCLUSIONS: Management of advanced corneal ectasia is a significant challenge for corneal surgeons. Many surgical approaches have been developed, so there is a large arsenal of surgical operations to correct post-PK ectasia. Among them, large-diameter anterior lamellar keratoplasty may be a viable, safer, and effective alternative to PK for the correction of post-keratoplasty ectasia.

20 February 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ELEnrico Lupardi
Enrico Lupardi
GLGian Luca Laffi
Gian Luca Laffi
AMAntonio Moramarco
Antonio Moramarco
PBPiero Barboni
Piero Barboni
Luigi FontanaLuigi Fontana
Luigi Fontana
Transient hypotony is the most common early complication after Preserflo MicroShunt (PMS) implantation. High myopia is a risk factor for the development of postoperative hypotony-related complications; therefore, it is advisable that PMS implantation in patients should be performed while employing hypotony preventive measures. The aim of this study is to compare the frequency of postoperative hypotony and hypotony-related complications in high-risk myopic patients after PMS implantation with and without intraluminal 10.0 nylon suture stenting. This is a retrospective, case–control, comparative study of 42 eyes with primary open-angle glaucoma (POAG) and severe myopia that underwent PMS implantation. A total of 21 eyes underwent a non-stented PMS implantation (nsPMS), while in the remaining eyes (21 eyes), PMS was implanted with an intraluminal suture (isPMS group). Hypotony occurred in six (28.57%) eyes in the nsPMS group and none in the isPMS group. Choroidal detachment occurred in three eyes in the nsPMS group; two of them were associated with the shallow anterior chamber and one was associated with macular folds. At 6 months after surgery, the mean IOP was 12.1 ± 3.16 mmHg and 13.43 ± 5.22 mmHg (p = 0.41) in the nsPMS and isPMS group, respectively. PMS intraluminal stenting is an effective measure to prevent early postoperative hypotony in POAG highly myopic patients.

1 November 2020 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
AMAntonio Moramarco
Antonio Moramarco
VMvalentina mastrofilippo
valentina mastrofilippo
MRMaria Grazia Romano
Maria Grazia Romano
DIDanilo Iannetta
Danilo Iannetta
LBLuca Braglia
Luca Braglia
LFLuigi Fontana
Luigi Fontana
PURPOSE: To investigate the long-term efficacy and safety of continuous light-accelerated corneal cross-linking (CXL) in patients with progressive keratoconus. METHODS: This retrospective study analyzed 29 eyes of 29 consecutive patients with progressive keratoconus treated with epithelium-off riboflavin-ultraviolet induced accelerated CXL (30 mW/cm 2 –7.2 joules/cm 2 ). Uncorrected (UDVA) and corrected (CDVA) distance visual acuity, keratometry measurements at 3 and 6 mm (Kmax, Kmin, and Kmean), topographic astigmatism, central corneal thickness, anterior corneal aberrometric analysis (at 3 and 6 mm), endothelial cell density, and central foveal thickness were evaluated before and 24 and 60 months after surgery. RESULTS: UDVA significantly improved at 60 months postoperatively ( P = .028). Kmax and Kmean at 3 mm significantly decreased at 24 ( P = .009 and .006, respectively) and 60 ( P = .017 and .034, respectively) months postoperatively, whereas Kmin significantly decreased only at 24 months postoperatively ( P = .032). Kmax at 6 mm significantly decreased at 24 and 60 months postoperatively ( P = .035 and .027, respectively). Cylinder error significantly decreased at 24 and 60 months postoperatively ( P = .001 and .023, respectively). Wavefront aberration variables remained unchanged after surgery, except for spherical aberration at 6 mm that decreased at 24 and 60 months postoperatively ( P = .038 and .031, respectively) and trefoil at 0° that significantly decreased at 24 months postoperatively ( P < .005). Endothelial cell density and central foveal thickness showed no changes from baseline. CONCLUSIONS: Accelerated CXL was found to be effective in halting keratoconus progression and improving some of the visual, topographic, and wavefront aberration variables evaluated. High energy irradiance did not induce significant changes in corneal transparency, endothelial cell density, and central foveal thickness. [ J Refract Surg . 2020;36(11):724–730.]

22 April 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AMAntonio Moramarco
Antonio Moramarco
NGNatallie di Geronimo
Natallie di Geronimo
MAMatteo Airaldi
Matteo Airaldi
LGLorenzo Gardini
Lorenzo Gardini
FSFrancesco Semeraro
Francesco Semeraro
Luigi FontanaLuigi Fontana
Luigi Fontana
Intraoperative OCT is an innovative and promising technology which allows anterior and posterior segment ocular surgeons to obtain a near-histologic cross-sectional and tomographic image of the tissues. Intraoperative OCT has several applications in ocular surgery which are particularly interesting in the context of corneal transplantation. Indeed, iOCT images provide a direct and meticulous visualization of the anatomy, which could guide surgical decisions. In particular, during both big-bubble and manual DALK, the visualization of the relationship between the corneal layers and instruments allows the surgeon to obtain a more desirable depth of the trephination, thus achieving more type 1 bubbles, better regularity of the plane, and a reduced risk of DM perforation. During EK procedures, iOCT supplies information about proper descemetorhexis, graft orientation, and interface quality in order to optimize the postoperative adhesion and reduce the need for re-bubbling. Finally, mushroom PK, a challenging technique for many surgeons, can be aided through the use of iOCT since it guides the correct apposition of the lamellae and their centration. The technology of iOCT is still evolving: a larger field of view could allow for the visualization of all surgical fields, and automated tracking and iOCT autofocusing guarantee the continued centration of the image.

2 February 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
PVPietro Viola
Pietro Viola
ENEnrico Neri
Enrico Neri
TOTommaso Occhipinti
Tommaso Occhipinti
MPMohit Parekh
Mohit Parekh
RCRoberto Cian
Roberto Cian
AIAlfonso Iovieno
Alfonso Iovieno
(1) Background: This study offers a biexponential model to estimate corneal endothelial cell decay (ECD) following preloaded “endothelium-in” Descemet membrane endothelial keratoplasty (DMEK) in Fuchs’ endothelial corneal dystrophy (FECD) patients; (2) Methods: A total of 65 eyes undergoing DMEK alone or combined with cataract surgery were evaluated. The follow-up period was divided into an early phase (first 6 months) and a late phase (up to 36 months). Endothelial cell count (ECC) and endothelial cell loss (ECL) were analyzed; (3) Results: The half time of the ECD was 3.03 months for the early phase and 131.50 months for the late phase. The predicted time-lapse interval to reach 500 cells/mm2 was 218 months (18.17 years), while the time-lapse interval to reach 250 cells/mm2 was 349 months (29.08 years). There was no statistically significant difference between the ECL in DMEK combined with cataract extraction and DMEK alone at 24 months (p ≥ 0.20). At the late phase, long-term ECL prediction revealed a lower ECC half time in patients undergoing DMEK combined with cataract surgery (98.05 months) than DMEK alone (250.32 months); (4) Conclusions: Based on the mathematical modeling, a predicted average half-life of a DMEK graft could reach 18 years in FECD. Moreover, combining cataract extraction with DMEK could result in excessive ECL in the long term.