Rita Mencucci

Dr. Rita Mencucci

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2020 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
RMRita Mencucci
Rita Mencucci
MCMichela Cennamo
Michela Cennamo
DVDaniel Venturi
Daniel Venturi
RVRoberto Vignapiano
Roberto Vignapiano
EFEleonora Favuzza
Eleonora Favuzza
Purpose: To compare visual outcomes, contrast sensitivity, optical quality, spectacle independence, and visual disturbances in patients implanted with 2 models of monofocal intraocular lenses (IOLs). Setting: Eye Clinic, Department of NEUROFARBA, University of Florence, Italy. Design: Prospective case series Methods: Patients without ocular comorbidities and corneal astigmatism less than 0.75 diopters (D) had cataract surgery with bilateral implantation of either of 2 monofocal IOLs, the Tecnis ZCB00 or the Tecnis Eyhance ICB00 (Johnson & Johnson Vision Care, Inc.). Six months postoperatively, monocular and binocular uncorrected and corrected (at 4 m) distance visual acuities, as well as uncorrected (UIVA), distance corrected, and corrected intermediate (at 66 cm) and near (at 40 cm) visual acuities were measured. Photopic contrast sensitivity, binocular defocus curve, objective scatter index (OSI), Strehl ratio, modulation transfer function (MTF) cutoff, halo and glare perception, and spectacle independence were also evaluated. Results: A total of 80 eyes of 40 patients were evaluated in this study. Although monocular and binocular uncorrected and corrected distance and near visual acuities were similar between groups, monocular and binocular UIVA were significantly higher in the Eyhance group. There were no statistically significant differences between the 2 groups in terms of photopic contrast sensitivity, OSI, MTF cutoff, Strehl ratio, and glare and halo perception. The ICB00 IOL provided better spectacle independence than the ZCB00 IOL for intermediate distance. Conclusions: In patients without ocular comorbidities, the Eyhance ICB00 IOL provided better UIVA and higher intermediate spectacle independence without impairment of far vision and visual quality, compared with the ZCB00 IOL.

6 July 2018 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
RMRita Mencucci
Rita Mencucci
EFEleonora Favuzza
Eleonora Favuzza
OCOrsola Caporossi
Orsola Caporossi
ASAlfonso Savastano
Alfonso Savastano
Stanislao RizzoStanislao Rizzo
Stanislao Rizzo

1 August 2006 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
RMRita Mencucci
Rita Mencucci
CPClaudia Ponchietti
Claudia Ponchietti
GVGianni Virgili
Gianni Virgili
FGFabrizio Giansanti
Fabrizio Giansanti
UMUgo Menchini
Ugo Menchini
To compare corneal endothelial changes after phacoemulsification performed with a standard technique versus a bimanual microincision cataract surgery (MICS) technique. University ophthalmology department. Eighty patients scheduled for routine cataract surgery were randomized into 2 groups; 40 eyes had standard stop-and-chop phacoemulsification (standard group) and 40 eyes had stop-and-chop phacoemulsification with microincision surgery (MICS group). Central corneal endothelial cell counts, coefficient of variation in cell size, hexagonality, and pachymetry were assessed preoperatively and 1 and 3 months postoperatively. The mean preoperative cell count in the entire sample was 2245 cells/mm2 +/- 37 (SE). The mean decreased by 102 cells at 1 month (95% confidence interval [CI], -133 to -71; P < .001) and by 144 cells at 3 months (95% CI, -187 to -102; P < .001). The difference between the standard group and the MICS group was 25 cells at baseline (95% CI, -169 to 120 cells; P = .739), 19 cells at 1 month (95% CI, -163 to 126; P = .799), and 19 cells at 3 months (95% CI, -164 to 125; P = .793). There were no changes in the coefficient of variation or morphology in the overall sample, and the pattern of change did not differ between the 2 groups. Corneal thickness increased by 10.2 microm in the overall sample (95% CI, +4.5 to +16.0; P < .001) and approached baseline values by 3 months with an increase of 3.4 microm (95% CI, -4.1 to 10.8; P = .372). There was no difference in corneal thickness between the groups. No significant differences in corneal endothelial cell loss or endothelial morphology were found between MICS and standard incision techniques.

1 January 2010 in Clinical & Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
RMRita Mencucci
Rita Mencucci
MMMirca Marini
Mirca Marini
IPIacopo Paladini
Iacopo Paladini
ESErica Sarchielli
Erica Sarchielli
ESEleonora Sgambati
Eleonora Sgambati
GVGabriella B Vannelli
Gabriella B Vannelli

1 August 2015 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
RMRita Mencucci
Rita Mencucci
CBCarlotta Boccalini
Carlotta Boccalini
RCRoberto Caputo
Roberto Caputo
EFEleonora Favuzza
Eleonora Favuzza
To evaluate the efficacy and safety of using sodium hyaluronate 0.1% and carboxymethylcellulose 0.5% artificial tears for ocular discomfort and tear-film stability in eyes after cataract surgery. Twenty ophthalmic centers in Italy. Prospective randomized case series. This study enrolled patients scheduled for unilateral cataract surgery. After surgery, patients received artificial tears and a topical steroid-antibiotic (study group) or topical steroid-antibiotic alone (control group) and were assessed postoperatively at 1 and 5 weeks. Outcome measures were tear breakup time (TBUT), ocular surface disease index (OSDI), frequency of dry-eye symptoms evaluated using a visual analog scale (VAS), and corneal fluorescein staining. The study comprised 282 patients. At 5 weeks, the mean TBUT was statistically significantly higher in the study group than in the control group (P = .0003). The mean OSDI score statistically significantly improved in both groups from 1 to 5 weeks (P < .0001 for both groups); however, there was no statistically significant difference between the groups at these timepoints. The artificial tears statistically significantly improved VAS-assessed dry-eye symptoms in the study group compared with the control group at 5 weeks (P < .001). The mean corneal fluorescein staining was significantly reduced in the study group compared with the control group at 5 weeks (P = .002 versus P = .05, respectively). No treatment-related adverse events were reported. Sodium hyaluronate 0.1% and carboxymethylcellulose 0.5% ophthalmic solution was effective and well tolerated in reducing dry-eye disease symptoms and improving the clinical outcome after cataract surgery. No author has a financial or proprietary interest in any material or method mentioned.

16 March 2023 in Frontiers in Medicine
Verified
Journal Article
Open access
RMRita Mencucci
Rita Mencucci
SSSimone Stefanini
Simone Stefanini
EFEleonora Favuzza
Eleonora Favuzza
MCMichela Cennamo
Michela Cennamo
CVChiara De Vitto
Chiara De Vitto
EMEnrico Mossello
Enrico Mossello
Cataract is a leading cause of visual impairment in old age. Lens opacification is notoriously associated with several geriatric conditions, including frailty, fall risk, depression and cognitive impairment. The association is largely attributable to visual impairment, while other mechanisms, associated with extraocular comorbidity and lifestyle, might partly explain this correlation. Available literature suggests that cataract surgery may be effective in decreasing fall risk, improving depressive symptoms and limiting the risk of cognitive impairment and dementia incidence, although intervention studies on these outcomes are still limited. In this review we also emphasize the need to move from the concept of visual acuity to functional vision, especially in the context of the geriatric patient. Research is needed regarding the effect on the cited outcomes of different cataract treatment strategies, such as systematic bilateral versus monolateral surgery and use of different intraocular lenses.