Traditional methods for detecting high-impedance faults (HIFs) in distribution networks primarily rely on constructing fault diagnosis models using one-dimensional zero-sequence current sequences. A single diagnostic model often limits the deep exploration of fault characteristics. To improve the accuracy of HIF detection, a new method for detecting HIFs in active distribution networks is proposed. First, by applying continuous wavelet transform (CWT) to the collected zero-sequence currents under various operating conditions, the time–frequency spectrum (TFS) is obtained. An optimized algorithm, modified empirical wavelet transform (MEWT), is then used to denoise the zero-sequence current signals, resulting in a series of intrinsic mode functions (IMFs). Secondly, the intrinsic mode functions (IMFs) are transformed into a two-dimensional spatial domain fused image using the symmetric dot pattern (SDP). Finally, the TFS and SDP images are synchronized as inputs to a hybrid convolutional neural network (Hybrid-CNN) to fully explore the system’s fault features. The Sigmoid function is utilized to achieve HIF detection, followed by simulation and experimental validation. The results indicate that the proposed method can effectively overcome the issues of traditional methods, achieving a detection accuracy of up to 98.85% across different scenarios, representing a 2–7% improvement over single models.
A method is proposed to address the challenging issue of load prediction in user-level integrated energy systems (IESs) using a composite VTDS model. Firstly, an IES multi-dimensional load time series is decomposed into multiple intrinsic mode functions (IMFs) using variational mode decomposition (VMD). Then, each IMF, along with other influential features, is subjected to data dimensionality reduction and clustering denoising using t-distributed stochastic neighbor embedding (t-SNE) and fast density-based spatial clustering of applications with noise (FDBSCAN) to perform major feature selection. Subsequently, the reduced and denoised data are reconstructed, and a time-aware long short-term memory (T-LSTM) artificial neural network is employed to fill in missing data by incorporating time interval information. Finally, the selected multi-factor load time series is used as input into a support vector regression (SVR) model optimized using the quantum particle swarm optimization (QPSO) algorithm for load prediction. Using measured load data from a specific user-level IES at the Tempe campus of Arizona State University, USA, as a case study, a comparative analysis between the VTDS method and other approaches is conducted. The results demonstrate that the method proposed in this study achieved higher accuracy in short-term forecasting of the IES’s multiple loads.
High-impedance fault (HIF) feeder detection in resonant-grounded active distribution systems remains a challenging issue. In practice, fault currents are typically weak, and the integration of distributed generation (DG) often distorts fault signatures, significantly limiting the effectiveness of existing detection techniques. This paper presents a novel HIF feeder detection method based on the fusion of zero-sequence current (ZSC) cross-correlation polarity analysis and harmonic wavebody similarity matching. Firstly, the HIF mechanism is examined, and the impact of DG on ZSC behavior is characterized, revealing polarity differences among feeders. To suppress high-frequency interference, variational mode decomposition (VMD) is employed to extract low-frequency components indicative of ZSC polarity, which are then subjected to cross-correlation analysis and used as the primary detection indicator. When ZSCs are heavily distorted due to DG, harmonic wavebody similarity serves as a supplementary detection feature. A comprehensive detection criterion is subsequently formulated by combining both analyses. Simulation and experimental results demonstrate that under HIF conditions, the proposed method is robust against variations in fault location, fault type, and noise interference, and can accurately identify the faulty feeder. Moreover, it remains effective for arc grounding, grass grounding, and pond grounding scenarios, highlighting its strong practical applicability.