Thermal mass of buildings as well as domestic hot water tanks represent interesting sources of thermal energy storage readily available in the existing building stock. To exploit them to their full potential, advanced control strategies and a coupling to the power grid with heat pump systems represent the most promising combination. In this work, model predictive control (MPC) strategies are developed and tested in a semi-virtual environment laboratory setup: a real heat pump is operated from within a controlled climate chamber, and coupled with the loads of a virtual building, i.e. a detailed dynamic building simulation tool. Different MPC strategies are tested in this laboratory setup, with the goals to minimize either the delivered thermal energy to the building, the operational costs of the heat pump, or the CO2 emissions related to the heat pump use. The results highlight the ability of the MPC controller to perform load-shifting by charging the thermal energy storages at favorable times, and the satisfactory performance of the control strategies is analyzed in terms of different indicators such as costs, comfort, carbon footprint, energy flexibility. The practical challenges encountered during the implementation with a real heat pump are also discussed and provide additional valuable insights.
In this study, simulation work has been carried out to investigate the impact of a demand-side management control strategy in a residential nZEB. A refurbished apartment within a multi-family dwelling representative of Mediterranean building habits was chosen as a study case and modelled within a simulation framework. A flexibility strategy based on set-point modulation depending on the energy price was applied to the building. The impact of the control strategy on thermal comfort was studied in detail with several methods retrieved from the standards or other literature, differentiating the effects on day and night living zones. It revealed a slight decrease of comfort when implementing flexibility, although this was not prejudicial. In addition, the applied strategy caused a simultaneous increase of the electricity used for heating by up to 7% and a reduction of the corresponding energy costs by up to around 20%. The proposed control thereby constitutes a promising solution for shifting heating loads towards periods of lower prices and is able to provide benefits for both the user and the grid sides. Beyond that, the activation of energy flexibility in buildings (nZEB in the present case) will participate in a more successful integration of renewable energy sources (RES) in the energy mix.