Kye-Shin Lee

Dr. Kye-Shin Lee

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 October 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ZHZaniar Hoseini
Zaniar Hoseini
MNMasoud Nazari
Masoud Nazari
KLKye-Shin Lee
Kye-Shin Lee
HCHae Chung
Hae Chung
This work describes a compact and low-power current feedback instrumentation amplifier (CFIA) that can effectively eliminate differential electrode offset (DEO), amplifier input offset, and light motion artifacts. The proposed approach is using a local feedback loop in the first stage of the CFIA which can eliminate DC and low frequency offset whereas by-passes useful components such as EEG and ECG signals. As a result, the DEO and amplifier input offset can be eliminated in the first stage of the CFIA while still amplifying the desired signal components. This enables offset cancellation operation with low bias current that leads to higher energy efficiency compared to existing CFIA offset cancellation schemes. The proposed CFIA is implemented using CMOS 0.18Jm technology, that can eliminated up to 250mV DEO with supply voltage of 1.8V. Measurement results show CMRR 120 dB (without DEO) and 95 dB (with DEO of 250mV) at 10 Hz, input noise 3.8 JVrms, power consumption 12.7, and NEF 39 with core area of 73.6 10-3 mm2. Furthermore, the actual EEG and ECG waveforms are obtained using the proposed CFIA under an actual clinical setting.

3 April 2019 in IEEE Transactions on Wireless Communications
Verified
Journal Article
Closed access
MVMinh N. Vu
Minh N. Vu
NTNghi H. Tran
Nghi H. Tran
DWDissanayakage G. Wijeratne
Dissanayakage G. Wijeratne
KPKhanh Pham
Khanh Pham
KLKye-Shin Lee
Kye-Shin Lee
DNDuy H. N. Nguyen
Duy H. N. Nguyen
Low resolution analog-to-digital converter (ADC) has been considered as a promising solution to save power and cost in communication systems using high bandwidth and/or multiple RF chains. The goal of this work is to address the design of optimal signaling schemes and establish the capacity limit of Rician fading channels with low-resolution output quantization. This fading channel can be used to accurately model a wide range of wireless channels with line-of-sight (LOS) components, including emerging mmWave communications. The focus is on non-coherent fast fading channels where neither the transmitter nor the receiver knows the channel state information (CSI). By examining the continuity of the input-output mutual information, the existence of the optimal input signal is first validated. Then considering the case of 1-bit ADC, we show that the optimal input is π/2 circularly symmetric. A necessary and sufficient condition for an input signal to be optimal, which is referred to as the Kuhn-Tucker condition (KTC), and Lagrangian optimization problem are then established. By exploiting novel log-quadratic bounds on the Gaussian Q-function, it is then demonstrated that for a given mass point’s amplitude, the corresponding rotated mass points through the phase of LOS component must form a square grid centered at zero. Furthermore, the amplitude of the mass points in the optimal distribution can take on only one value. As a result, the capacity-achieving input with 1-bit ADC is a rotated quadrature phase-shift keying (QPSK) constellation, and the rotation angle depends on the Rician factor. The characterization of the optimal input has also been extended to the case of multi-bit ADCs. Specifically, it is shown that for a K-bit ADC, the optimal input is discrete having at most 22K mass points. In both cases of 1-bit and K-bit ADCs, the channel capacities are established in closed-form.

12 July 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HCHae Chung
Hae Chung
JLJi Hoon Lee
Ji Hoon Lee
JCJae Hyun Chung
Jae Hyun Chung
JHJung Ho Hong
Jung Ho Hong
SKSang Gu Kang
Sang Gu Kang
YKYong Min Kim
Yong Min Kim
The number of patients with sleep apnea, which may cause heart disease or stroke, is increasing worldwide. Polysomnography is the most reliable diagnostic method. However, it is expensive, and an accurate diagnosis is difficult because various sensors attached to the body can cause insomnia for sensitive patients. Several home diagnosis methods have been proposed to overcome these problems, but the accuracy is not guaranteed. In this paper, we propose a method for diagnosing hypopnea as well as sleep apnea comfortably at home using an IR camera. The proposed method requires the patients to wear a mask, which enables easy tracking and measurement of breathing even though they are lying on their side 90 degrees apart from the front. The diagnostic program converts the temperature changes of the mask surface received from the IR camera into the breathing waveform and calculates breathing cycles. Also, it defines five states and six events for state transition and makes the final diagnosis by calculating the duration and occurrence of apnea during the sleep period. As information, including thermal images and/or breathing waveforms, can be transmitted in real-time via the Internet, it is also possible to analyze the patient’s symptoms in a hospital or specialized care facility. The usefulness of the proposed device is verified by observing the breathing cycle and the duration of apnea according to various situations, including the type of mask, the number of subjects, and the angle and distance between the camera and the subject.

15 April 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MAMohammadreza Asgari
Mohammadreza Asgari
KLKye-Shin Lee
Kye-Shin Lee
This work describes a fully-integrated CMOS electrical conductivity sensor for wet media that incorporates the sensing electrodes and the readout circuitry in the same die. The proposed sensor is realized using standard CMOS technology where the top passivation layer is used to protect the sensing electrodes from corrosion. As a result, additional process steps for replacing the top metal layers with noble metals or creating protection layers for the sensing electrodes are not required. Furthermore, a harmonic oscillator with reconfigurable frequency is used for the sinusoidal stimulus generation, which can set the optimum detection frequency to maximize the sensitivity and accuracy of the sensor. The proposed electrical conductivity sensor is implemented using CMOS 0.18um technology with core area of 2.1 mm2 that includes the four sensing electrodes and the readout circuitry. The detection range of the proposed sensor spans three orders of magnitude from 0.02 mS/cm to 10 mS/cm.

1 August 2011
Verified
Conference Paper
Closed access
NKNikhil Reddy Karnati
Nikhil Reddy Karnati
KLKye-Shin Lee
Kye-Shin Lee
JCJoan Carletta
Joan Carletta
RVRobert Veillette
Robert Veillette
This paper presents a power-efficient poly-phase sharpened CIC filter for sigma-delta ADCs. In this scheme, by using a cascade of CIC filter and SCIC filter with proper optimization of the two-stage decimation structure, the power consumption can be considerably reduced compared to conventional SCIC filter architectures. Furthermore, poly-phase implementations for both the CIC and SCIC filter sections are used to further reduce the power. The proposed filter is designed with CMOS 1 μm technology, where the lowest power consumption is achieved among similar filter architectures.

12 October 2024 in Sensors
Verified
Journal Article
Open access
PDF file
JDJoseph Agyemang Duah
Joseph Agyemang Duah
KLKye-Shin Lee
Kye-Shin Lee
Byung-Gyu  KimByung-Gyu Kim
Byung-Gyu Kim
This work describes a self-powered wireless temperature sensor platform that can be used for foot ulceration monitoring for diabetic patients. The proposed self-powered sensor platform consists of a piezoelectric bimorph, a power conditioning circuit, a temperature sensor readout circuit, and a wireless module. The piezoelectric bimorph mounted inside the shoe effectively converts the foot movement into electric energy that can power the entire sensor platform. Furthermore, a sensor platform was designed, considering the energy requirement of 4.826 mJ for transmitting one data packet of 18 bytes. The self-powered sensor platform prototype was evaluated with five test subjects with different weights and foot shapes; the test results show the subjects had to walk an average of 119.6 s to transmit the first data packet and an additional average of 71.2 s to transmit the subsequent data packet. The temperature sensor showed a resolution of 0.1 °C and a sensitivity of 56.7 mV/°C with a power conditioning circuit efficiency of 74.5%.