Mohammed El Amine SLAMA

Dr. Mohammed El Amine SLAMA

Cardiff University
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 May 2021 in Energies
Verified
Journal Article
Open access
PDF file
MSMohammed El Amine SLAMA
Mohammed El Amine SLAMA
MAMaurizio Albano
Maurizio Albano
Abderrahmane HaddadAbderrahmane Haddad
Abderrahmane Haddad
RWRonald T. Waters
Ronald T. Waters
OCOliver Cwikowski
Oliver Cwikowski
OSOliver Scopes
Oliver Scopes
The aim of this study is the presentation of the results of an in-lab comparative study of electrical and thermal monitoring of artificially polluted, HTV-textured silicone rubber insulators, with different pollution levels. This work is a preliminary study of an in-situ monitoring of 400 kV SiR textured in a polluted environment. The results showed that the rms leakage current magnitude and pulses, and the average dissipated power depended on the pollution levels and the dry-bands formation. The discharge activity and their nature are governed by the pollution level and the voltage. A differentiation and a quantification between dry-band discharge onset and dry-band arc inception is highlighted.

1 October 2008
Verified
Conference Paper
Closed access
MSMohammed El Amine SLAMA
Mohammed El Amine SLAMA
HHHocine Hadi
Hocine Hadi
SFSamir Flazi
Samir Flazi
In this paper we study the influence of salts mixture on DC flashover voltage discharge characteristics. We used NaCl as principal salt and we adjoin it different salts. Results shows that mixture of salts gives different flashover voltage and current then NaCl on both polarity. A dimensional analysis has made for determining the relation between quantity of salt and constant of discharge N and n. The results of calculation shows that N and n are function of quantity of chalk and volume of CaCO3.

20 May 2022 in Energies
Verified
Journal Article
Open access
PDF file
MSMohammed El Amine SLAMA
Mohammed El Amine SLAMA
AKAdnan Krzma
Adnan Krzma
MAMaurizio Albano
Maurizio Albano
Abderrahmane HaddadAbderrahmane Haddad
Abderrahmane Haddad
Pollution flashover occurs when soluble and nonsoluble materials cover the surface of an insulator, and this may ultimately cause a reduction in its performance. In this paper, the common type of sodium chloride (NaCl) was used as a soluble pollutant (ESDD) and kaolin as a nonsoluble pollutant (NSDD). Samples of silicone rubber (SiR) insulators were selected for this study and fabricated at the Advanced High Voltage Engineering Research Centre (AHIVEC) at Cardiff University. The samples were preconditioned and polluted according to standard specifications. Additionally, the AC voltage ramp technique was used to achieve flashover (FOV) voltage with different pollution levels. The aim of this work was to investigate the effect of nonsoluble materials on flashover characteristics to understand their interaction with dry-band arcs by using FOV electrical equations and experimental data. The test results show that the FOV voltage of the silicone rubber insulator substantially decreased with the increase in both ESDD and NSDD values. It was also identified from these results that the dry-band arcs were considerably influenced by both ESDD and NSDD levels. This impact can be quantified by determining the variation of discharge parameters (N, n). Based on the FOV equations and experimental data, a mathematical model was suggested, taking into account the effect of both ESDD and NSDD.

22 June 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Open access
DPDavide Pinzan
Davide Pinzan
FBFabio Branco
Fabio Branco
Abderrahmane HaddadAbderrahmane Haddad
Abderrahmane Haddad
MSMohammed El Amine SLAMA
Mohammed El Amine SLAMA
MAMaurizio Albano
Maurizio Albano
Helder LeiteHelder Leite
Helder Leite
In High Voltage Direct Current (HVDC) systems, composite outdoor insulators play a critical role and focus is needed on the research of their failure. In the case of a pole to ground fault of a bipolar scheme, the healthy pole experiences an overvoltage similar to a Switching Impulse (SI) superimposed on the operational DC voltage. However, there is no standard test for such voltage superimposition. This paper investigates the performance of a composite insulator stressed with such superimposition under dry and rain conditions. To determine the direct voltage influence on the flashover voltage, the results have been compared with the SI only case. Four different rain conductivities have been used in the test programme. Both vertical and horizontal orientations have been studied. Most cases show that direct voltage pre-energisation has a negative impact on the flashover performance. The increase in rain conductivity leads to lower flashover values, and the horizontal orientation outperforms the vertical configuration. Under these test conditions, the flashover voltages were all larger than a typical DC operational switching surge. Thus, in the case of pole to ground fault, the healthy pole failure risk seems small. Further research is needed on higher voltages and polluted conditions.

28 January 2020 in Energies
Verified
Journal Article
Open access
PDF file
MSMohammed El Amine SLAMA
Mohammed El Amine SLAMA
Abderrahmane BeroualAbderrahmane Beroual
Abderrahmane Beroual
Abderrahmane HaddadAbderrahmane Haddad
Abderrahmane Haddad
The aim of this paper is the presentation of an analytical model of insulator flashover and its application for air at atmospheric pressure and pressurized SF6 (Sulfur Hexafluoride). After a review of the main existing models in air and compressed gases, a relationship of flashover voltage based on an electrical equivalent circuit and the thermal properties of the discharge is developed. The model includes the discharge resistance, the insulator impedance and the gas interface impedance. The application of this model to a cylindrical resin-epoxy insulator in air medium and SF6 gas with different pressures gives results close to the experimental measurements.

3 April 2020 in Energies
Verified
Journal Article
Open access
PDF file
HNHoussem Eddine Nechmi
Houssem Eddine Nechmi
MSMohammed El Amine SLAMA
Mohammed El Amine SLAMA
Abderrahmane HaddadAbderrahmane Haddad
Abderrahmane Haddad
GWGordon Wilson
Gordon Wilson
AC pre-discharge currents, breakdown, and flashover voltage measurements are reported in a 10 mm needle-plane arrangement in a 4% NovecTM 4710/96% CO2 gas mixture and compared with CO2 for pressures up to 8.8 bar abs. Flashover measurements were performed on different solid dielectrics (Al2O3_filled epoxy resins, PTFE (Polytetrafluoroethylene) and PE (polyethylene)) for different roughness surface finishes. The effect of fixed conducting needles at various positions on electrical strength is reported. A strong nonlinear behaviour as function of gas pressure was observed for all the studied parameters (gas, needle position, solid insulator, insulator roughness). The non-linear behaviour is attributed to the inception and quenching of glow corona, in the interval between inception and breakdown or flashover voltages. It is found that a 4% concentration of NovecTM 4710 in CO2 has a breakdown/flashover voltage ≈ 1.14 higher than CO2. The glow corona-induced stabilization effect is seen for pressures between 2 and 5 bar abs for all the studied parameters. The peak flashover voltage and its associated pressure of the different insulators are strongly dependent on surface roughness. At 8.8 bar abs, the flashover voltage level obtained with various materials was ordered as follows: PTFE > PE-UHMW > Epoxy > HDPE(High-density polyethylene).