Huizhi Wang

Dr. Huizhi Wang

School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2024 in Tissue Engineering Part B: Reviews
Verified
Journal Article
Closed access
Huizhi WangHuizhi Wang
Huizhi Wang
KHKaixin He
Kaixin He
Cheng-Kung ChengCheng-Kung Cheng
Cheng-Kung Cheng
After tendon or ligament reconstruction, the interface between the hard bone and soft connective tissue is considerably weakened and is difficult to restore through healing. The tendon/ligament-bone interface is mechanically the weakest point under tensile loading and is often the source of various postoperative complications, such as bone resorption and graft laxity. A comprehensive understanding of the macro- and micro- features of the native tendon/ligament-bone interface would be beneficial for developing strategies for regenerating the tissue. This paper discusses the structural, biological and mechanical features of the tendon/ligament-bone interfaces and how these can be affected by aging and loading conditions. Impact Statement This review provides an up-to-date summary of the structural, biological and mechanical features of the tendon/ligament-bone interfaces, and how these can be affected by aging and loading conditions. A thorough understanding of these features provides critical foundation for developing advanced techniques for ligament/tendon reconstruction and soft-hard tissue interface engineering.

7 July 2021 in Materials
Verified
Journal Article
Open access
PDF file
JSJian Su
Jian Su
JWJian-Jun Wang
Jian-Jun Wang
SYS.T. Yan
S.T. Yan
MZMin Zhang
Min Zhang
Huizhi WangHuizhi Wang
Huizhi Wang
Cheng-Kung ChengCheng-Kung Cheng
Cheng-Kung Cheng
Cobalt-chromium-molybdenum alloy (CoCrMo) and ceramic are the two most common materials for the femoral head in hip joint prostheses, and the acetabular liner is typically made from ultra-high molecular weight polyethylene (UHMWPE), highly cross-linked polyethylene (XLPE), or highly cross-linked polyethylene blended with Vitamin E (VEXLPE). The selection of suitable materials should consider both wear performance and cost-effectiveness. This study compared the wear rate between different friction pairs using a hip joint simulator and then recommended a suitable prosthesis based on the corresponding processing technology and cost. All wear simulations were performed in accordance with ISO 14242, using the same hip joint simulator and same test conditions. This study found that when using the same material for the femoral head, the XLPE and VEXLPE liners had a lower wear rate than the UHMWPE liners, and the wear rate of the XLPE liners increased after blending with Vitamin E (VEXLPE). There was no significant difference in the wear rate of XLPE when using a CoCrMo or ceramic head. Considering the wear rate and cost-effectiveness, a CoCrMo femoral head with an accompanying XLPE liner is recommended as the more suitable combination for hip prostheses.

18 November 2022 in Frontiers in Veterinary Science
Verified
Journal Article
Open access
QSQinyi Shi
Qinyi Shi
Huizhi WangHuizhi Wang
Huizhi Wang
KHKaixin He
Kaixin He
MTMingzhu Tao
Mingzhu Tao
Cheng-Kung ChengCheng-Kung Cheng
Cheng-Kung Cheng
Introduction: Pigs are widely used for clinical research on the anterior cruciate ligament (ACL) because of the similarity of the knee structure to the human knee. But evidence to support the suitability of using porcine samples to guide clinical practices is limited. This study aims to explore the qualitative and quantitative morphological features of the porcine knee and ACL, and to compare these with data on humans reported in literature.Methods: Nineteen porcine knees were used for this study. The bone structures were measured on coronal X-ray images. The length of the ACL was measured using a caliper. The ACL bone insertion sites were marked and measured on a digital photograph. The lengths of the long and short axis of the ACL isthmus were measured on the X-ray microscopy reconstructed images. The outcomes were compared with previously reported data on humans using an abstract independent-samples T test.Results: Qualitative observation indicated a similar location, orientation and general morphology of the porcine ACL to human ACLs. The major difference was the location of the ACL tibial insertion with respect to the anterior horn of the lateral meniscus (AHLM). The porcine ACL was split into AM and PL bundles by the AHLM, while the AHLM was adjacent to the anterolateral border of the ACL tibial insertion in human knees. The quantitative comparison showed no significant difference between the human and porcine ACL in terms of the length of the ACL, the width of the femoral condyle and tibial plateau, and the tibial interspinal width. However, the CSA, the lengths of the long and short axis of the ACL isthmus, and the femoral and tibial insertion areas of the porcine ACL were all significantly larger than the reported features in human knees.Conclusion: The location, orientation and basic morphology of the porcine ACL and knee are similar to humans. However, the two-bundle structure is more distinct in a porcine ACL, and the dimensions of the porcine ACL are generally larger. This study may provide useful information to researchers when assessing the feasibility and limitations of using porcine samples for research on the human ACL and knee.

27 September 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
Huizhi WangHuizhi Wang
Huizhi Wang
MTMingzhu Tao
Mingzhu Tao
QSQinyi Shi
Qinyi Shi
KHKaixin He
Kaixin He
Cheng-Kung ChengCheng-Kung Cheng
Cheng-Kung Cheng
The size of the anterior cruciate ligament (ACL) often varies between individuals, but such variation is not typically considered during ACL reconstruction (ACLR). This study aimed to explore how the size of the ACL affects the selection of a suitable graft diameter. A finite element model of a human knee was implanted with intact ACLs of different dimensions (0.95, 1 and 1.05 times the size of the original ACL) and with grafts of different diameters, to simulate ACLR (diameter 7.5–12 mm in 0.5 mm increments). The knee models were flexed to 30° and loaded with an anterior tibial load of 103 N, internal tibial moment of 7.5 Nm, and valgus tibial moment of 6.9 Nm. Knee kinematics (anterior tibial translation (ATT), internal tibial rotation (ITR) and valgus tibial rotation (VTR)) and ligament forces were recorded and compared among the different groups. The results showed that, compared with the intact knee, a graft diameter of 7.5 mm was found to increase the ATT and VTR, but reduce the graft force. Increasing the graft diameter reduced knee laxity and increased the graft force. A 10% increase in the size of the ACL corresponded to a 3 mm larger graft diameter required to restore knee stability and graft force after ACLR. It was concluded that the graft diameter should be selected according to the dimensions of the native ACL, for better restoration of knee functionality. This study may help to improve the clinical treatment of ACL ruptures.

15 September 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
RCRongshan Cheng
Rongshan Cheng
Huizhi WangHuizhi Wang
Huizhi Wang
Cheng-Kung ChengCheng-Kung Cheng
Cheng-Kung Cheng
Musculoskeletal injuries are increasing in conjunction with the aging of populations and the rising frequency of exercise

27 January 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
YLYuandong Li
Yuandong Li
XJXiaoxi Ji
Xiaoxi Ji
QYQingqing Yang
Qingqing Yang
Huizhi WangHuizhi Wang
Huizhi Wang
Cheng-Kung ChengCheng-Kung Cheng
Cheng-Kung Cheng
The deltoid ligament (DL) is the primary stabilizer of the medial ankle; however, a limited understanding of the functional roles of its various bundles hinders rational surgical decision-making. This study aims to investigate the roles of individual DL bundles in maintaining ankle stability and articular contact pressure and thus seeks to guide decisions on whether reconstruction is required for specific injuries. A validated finite element foot model was used to simulate isolated and multiple deficiencies in the DL bundle. The articular displacements, rotations, and peak talar cartilage contact pressure were evaluated under anterior drawer force and under internal–external rotation, eversion, and plantarflexion–dorsiflexion moments. Compared with the intact model, anterior tibiotalar ligament (ATTL) deficiency resulted in the greatest anterior drawer displacement (increase: 29%). Talonavicular ligament (TNL) deficiency caused the largest internal–external rotation and plantarflexion (increases in external rotation: 69%; in internal rotation: 10%; in plantarflexion: 32%). Tibiocalcaneal ligament (TCL) deficiency caused the largest eversion (increase: 93%). Deep posterior tibiotalar ligament (dPTTL) deficiency caused the largest dorsiflexion (increase: 68%). The maximum talar cartilage contact pressure occurred in the TNL-deficient model under the plantarflexion condition. In conclusion, individual DL bundles exhibit specific functions in terms of controlling multidirectional ankle stability—the ATTL, TNL, TCL, and dPTTL are the primary stabilizers for anterior translation, rotation/plantarflexion, eversion, and dorsiflexion, respectively. These findings provide a biomechanical rationale for personalized surgical strategies. When comprehensive DL reconstruction is not feasible, clinicians can prioritize the reconstruction of specific bundles according to the patient’s instability severity and functional demands across degrees of freedom.