Yuanjun Hou

Yuanjun Hou

Auto-generated profile, based on publicly available information

Yuanjun Hou


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 November 2022 in Energies
Verified
Journal Article
Open access
PDF file
JDJiawei Dong
Jiawei Dong
CGChunyang Gong
Chunyang Gong
JBJun Bao
Jun Bao
LZLihua Zhu
Lihua Zhu
YHYuanjun Hou
Yuanjun Hou
Zhixin WangZhixin Wang
Zhixin Wang
As an important form of distributed renewable energy utilization and consumption, the multi-parallel inverter microgrid system works in both an isolated and grid-connected operation mode. Secondary-frequency and voltage-regulation control are very important in solving problems that appears in these systems, such as the distributed secondary-frequency regulation real-time scheme, voltage and reactive power balancing, and the secondary-frequency regulation control under the disturbances and unbalanced conditions of a microgrid system. This paper introduces key technologies related to these issues, such as the consensus algorithm and event-triggered technique, the dynamic and adaptive virtual impedance technique, and the robust and self-anti-disturbance control technique. Research and design methods such as small-signal state-space analysis, the Lyapunov function design method, the impedance analysis method, μ-synthesis design, and the LMI matrix design method are adopted to solve the issues in secondary-frequency regulation and voltage regulation. As the number of inverters increases, the structure of the microgrid becomes more and more complex. Suggestions and prospects for future research are provided to realize control with low-communication technology and a distributed scheme. Finally, for the case study, the droop-control model and primary frequency/voltage deviation of a multi-parallel inverter microgrid system is analyzed, and a state-space model of a multi-parallel inverter microgrid system with a droop-control loop is established. Then, the quantitative relationship between the primary frequency/voltage deviation and the active and reactive power output in the system is discussed. The methods and problems of centralized and decentralized secondary-frequency regulation methods, secondary-frequency regulation methods based on a consensus algorithm and an event-triggered mechanism, reactive power and voltage equalization, power distribution, and small-signal stability of the multiple parallel inverter microgrid system regarding the virtual impedance loop are analyzed.

15 November 2026 in Energies
Verified
Journal Article
Open access
PDF file
YYYongfeng Yao
Yongfeng Yao
FBFei Bian
Fei Bian
PLPeizheng Liu
Peizheng Liu
HWHao Wang
Hao Wang
SFShousai Fu
Shousai Fu
YHYuanjun Hou
Yuanjun Hou
High penetration of distributed photovoltaic (PV) generation complicates coordinated PV–energy storage system (ESS) planning and network operation, especially where discrete and continuous reactive-power devices coexist. This study develops a screening-assisted planning–operation framework incorporating capacitor banks (CBs) and static var compensators (SVCs). A time-averaged voltage-stress index (TVSI) and network-loss sensitivity (NLS) identify candidate installation buses. The screened layout A1 is compared with the reference layout A0 at matched PV/ESS ratings under prescribed and coordinated reactive-power control. Under coordinated control, A0 achieves 1.14% lower daily operating cost and 13.17% lower physical voltage deviation than A1; thus, the screened layout is not adopted for subsequent capacity planning. At the retained A0 sites, PV/ESS capacities and seasonal dispatch are jointly optimized using single-level mixed-integer second-order cone programming (MISOCP) with relaxed branch-flow constraints. The formulation includes PV availability and curtailment, ESS state-of-charge dynamics, voltage and branch-current limits, CB configuration-change limits and stage-operation costs, and a unified upstream electricity-purchase boundary. Four-season profiles and probability-weighted PV–load–price scenarios support deterministic and scenario-based planning, with common-input evaluation and independent alternating-current (AC) power-flow verification. In the IEEE 33-bus system, coordinated control reduces A0’s physical voltage-deviation index by 42.96% relative to prescribed control, at a higher daily cost. Scenario-based planning yields a 0.43% lower observed annualized test cost than deterministic planning on the common 30-day sample, while both satisfy the checked AC limits.