Chunrui Liu

Mr. Chunrui Liu

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 July 2020 in IEEE Access
Verified
Journal Article
Open access
CLChunrui Liu
Chunrui Liu
FDFujie Deng
Fujie Deng
LSLei Shi
Lei Shi
FWFeng Wang
Feng Wang
Most transformer substations in power supply facilities rely on sulfur hexafluoride electrical equipment. A sulfur hexafluoride gas leak can cause serious health concerns if effective measures are not adopted in time. Therefore, in this study, a sulfur hexafluoride gas leakage monitoring, early-warning, and emergency disposal model was established. First, taking the main transformer chamber of an underground transformer substation as the research object, a 3D-model was built, and a numerical simulation was performed. Second, the simulation results were utilized to determine the dispersion and concentration distribution of the sulfur hexafluoride gas, identify concentration-sensitive areas, and arrange sensors based on the simulation results, to ensure early-warning in case of leaks. Then, a sulfur hexafluoride gas leakage monitoring and early-warning model was built based on the data collected using sensors at the monitoring points; thereafter, a construction method was developed for a sulfur hexafluoride gas leakage emergency disposal model, which can be referenced to establish a leakage gas recycling system. This paper also provides some recommendations regarding the determination of the optimal conditions for this emergency recycling device, which can be utilized to maintain the concentration of sulfur hexafluoride gas below a specified value and to construct a recycling time prediction model. The results of the study can provide a theoretical basis for sulfur hexafluoride gas leakage early-warning and emergency disposal, which will contribute to the prevention of suffocation-related accidents.

14 December 2022 in Aerospace
Verified
Journal Article
Open access
PDF file
CLChunrui Liu
Chunrui Liu
LHLidong He
Lidong He
XJXingyun Jia
Xingyun Jia
HZHaozhe Zhu
Haozhe Zhu
TCTao Chen
Tao Chen
WWWenhao Wang
Wenhao Wang
The rotary seal is a key component of the aero engine. Under actual working conditions, most rotary seals always operate in an eccentric state (caused by installation errors), and when a large eccentricity occurs, it may lead to a large amount of gas leakage, resulting in a decrease in aero engine efficiency, which ultimately affects the reliability and life of the aero engine. Therefore, the effect of installation error on the rotary seal of the aero engine was studied in this research. The flow field numerical models of the honeycomb seal, labyrinth seal, and hybrid labyrinth–honeycomb seal were established, the effects of the honeycomb seal, labyrinth seal, and hybrid labyrinth–honeycomb seal on leakage were numerically analyzed, the sealing mechanisms of three types of seals were revealed, and the effect of radial eccentricity on the leakage of three types of seals was also studied. Additionally, the high-pressure and high-speed rotary seal experiment bench was improved, the effect of eccentricity on the leakage characteristics of the honeycomb seal, labyrinth seal, and hybrid labyrinth–honeycomb seal was studied using the improved experiment bench, and the leakage characteristics of the three types of seals were compared under the same condition. The experimental results are consistent with the numerical simulation results; the honeycomb seal is the least sensitive to eccentricity, and its sealing performance is the best. The research results in this paper reveal the seal mechanisms of the honeycomb seal, labyrinth seal, and hybrid labyrinth–honeycomb seal and demonstrate the effect law of eccentricity regarding the leakage characteristics of these three types of seals. The results of this research can provide theoretical support for aero engine efficiency improvement.

9 March 2020 in IEEE Access
Verified
Journal Article
Open access
CLChunrui Liu
Chunrui Liu
WGWunan Gu
Wunan Gu
LSLei Shi
Lei Shi
FWFeng Wang
Feng Wang
Sulfur hexafluoride (SF6) gas leakage in populous urban areas, once occurring, can cause death from suffocation if its concentration largely exceeds 1000ppm and oxygen concentration is low than 19 vol-%. Leakage that cannot be detected and responded to with prompt and effective measures can even lead to large death tolls. Presently, few systematic technical approaches to monitoring, early warning, consequence prediction, and emergency response of SF6 leakage have been reported. In this paper, a method for constructing the early-warning and emergency response system for SF6 leakage in substations is proposed. Firstly, the concentration distribution of leaked SF6 gas at different leakage points within the substation space is analyzed using CFD simulation to determine the coordinates of sensitive areas where the exceeding of the threshold value of SF6 concentrations is first detected and thus to ascertain sensor monitoring points. By altering leakage locations and leakage orifice diameters within the substation space, the data concerning the coupling relationship between leakage time, leakage orifice diameter, and concentration are obtained, and a prediction model of diffusion concentration of SF6 leakage in substations is established through regression. Based on the prediction model, an emergency response system for SF6 leakage in substations is constructed; additionally, in combination with safety management data of substations, the files required for emergency responses to SF6 leakage can be identified immediately after occurrence, which provide a guidance for on-field personnel to take emergency responses and safety prevention measures. In this paper, a case study of a substation leakage event is presented to describe the method to construct an early warning and emergency response system for leakage in substations, as well as the application of the method. The results of this research can provide a theoretical basis for early warning and emergency response to SF6 leakage, thereby improving the inherent safety levels of substations.

19 September 2022 in Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology
Verified
Journal Article
Closed access
CLChunrui Liu
Chunrui Liu
ZYZe Yan
Ze Yan
WDWeize Dai
Weize Dai
LHLidong He
Lidong He
XJXingyun Jia
Xingyun Jia
LZLe Zhang
Le Zhang
In order to reduce the leakage and the temperature of the end face of the piston ring to prolong its service life, an experimental research of the piston ring with different types of end face structures is carried out. In this research, a high-pressure and high-speed rotary seal experiment bench is built, and the leakage and temperature experiment of piston rings such as traditional type, micro-pit type, circular arc groove type and V-groove type are carried out. The results show that when the pressure is 1–2 MPa and the speed is 1000–5000 rpm, the V-groove type piston ring has the best comprehensive performance among the four different structures of the piston rings, which can not only reduce the temperature of the piston ring to prolong the service life of the piston ring, but also reduce the leakage of the piston ring. The results of this research reveal the influence of different types of end face structures on the leakage and temperature of the piston ring, which can provide theoretical support for its optimal design.

12 May 2022 in International Journal of Turbo & Jet-Engines
Verified
Journal Article
Closed access
CLChunrui Liu
Chunrui Liu
ZYZe Yan
Ze Yan
XWXuezhi Wang
Xuezhi Wang
LHLidong He
Lidong He
XJXingyun Jia
Xingyun Jia
WWWenhao Wang
Wenhao Wang
The accumulation of catalyst dust at the honeycomb seal for a long time will lead to the honeycomb seal cell blockage, weaken the seal effect of the honeycomb seal, and directly affect the safe and stable operation of the flue gas turbine. Therefore, a research on the influence of honeycomb cell blockage on the seal leakage characteristics is carried out. The flow field model of honeycomb seal is established, and the influence of cell blockage on the leakage characteristics of honeycomb seal is analyzed. A seal leakage characteristic experiment bench is built, and the numerical simulation results are verified by the experiment bench. Compared with the honeycomb seal without blockage, the leakage of the honeycomb seal with a blockage rate of 25% increases by about 6.5%, while the leakage of the honeycomb seal with a blockage rate of 25% obtained by the experiment increases by about 6.3%. The numerical simulation results are in good agreement with the experimental results. The results of this research provide theoretical support for revealing the seal leakage characteristics of honeycomb seals under blockage faults.

29 August 2022 in International Journal of Turbo & Jet-Engines
Verified
Journal Article
Closed access
LZLe Zhang
Le Zhang
LHLidong He
Lidong He
ZYZe Yan
Ze Yan
WDWeize Dai
Weize Dai
XJXingyun Jia
Xingyun Jia
WWWenhao Wang
Wenhao Wang
Aiming at the problem of frictional heat generation under high pressure and high speed of the piston ring, the V-groove piston ring is proposed. The finite element analysis method is used to compare and analyze the temperature distribution law of the traditional piston ring and V-groove piston ring. The experimental study on the temperature rise of the piston ring seal is carried out by using the high-pressure and high-speed rotating sealing experimental bench. The experimental results are consistent with the simulation results. The results show that when the rotor speed increases by 1000 rpm, the temperature rise of the traditional piston ring increases by 18.4%, the V-groove piston ring increases by 17.2%. For every 0.5 MPa increase in the pressure applied to the piston ring, the temperature rise of the traditional piston ring increases by 9.2%, the V-groove piston ring increases by 5.8%. The same under the working conditions, the temperature rise of the V-groove piston ring is reduced by 21–29% compared with the traditional piston ring, and the leakage of the V-groove piston ring is reduced by 12–19% compared with the traditional piston ring. The synergistic design of low temperature rises and low leakage of the piston ring.