zhipeng yu

Mr. zhipeng yu


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
ZYzhipeng yu
zhipeng yu
XZXiaofeng Zhao
Xiaofeng Zhao
CAChunpeng Ai
Chunpeng Ai
ZWZuofei Wu
Zuofei Wu
XZXiaohan Zhao
Xiaohan Zhao
HZHongquan Zhang
Hongquan Zhang
Write-once-read-many-times (WORM) memory belonging to an important non-volatile memory type achieves the read-only state after the write operation and is used in the fields of data security storage widely. WORM memory has been developed based on a variety of materials. In recent years, halide perovskites have become the research hotspot material for this memory due to its excellent properties. Here, the all-inorganic CsPbBr3 perovskite thin film was prepared on a FTO substrate by using a two-step method. The prepared CsPbBr3 thin films have the characteristics of densely packed crystal grains and smooth surface. The device, having the FTO/CsPbBr3/Al sandwich structure by evaporating the Al electrode onto the CsPbBr3 thin film, represents the typical WORM behavior, with long data retention time (104 s), a low operation voltage (2.1 V) and a low reading voltage (0.1 V). Additionally, the resistance transition mechanism of the resulting WORM devices was analyzed.

11 February 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
ZYzhipeng yu
zhipeng yu
XZXiaofeng Zhao
Xiaofeng Zhao
WLWeiwei Liu
Weiwei Liu
SLSusu Li
Susu Li
ZYZijiang Yang
Zijiang Yang
HZHongquan Zhang
Hongquan Zhang
This work researched the effects of irradiation on the current-voltage characteristics and voltage magnetic sensitivity of the silicon magnetic sensitive transistor (SMST). The 1-MeV electron irradiation source was used to irradiate the SMST. The irradiation fluences were 1 × 1012 e/cm2, 1 × 1013 e/cm2 and 1 × 1014 e/cm2, respectively (the irradiation flux was 1 × 1010 cm−2·s−1). The experimental results demonstrate that the collector current (IC) of the SMST occurs attenuation after irradiation under the same collector voltage (VCE) and the base current (IB). The attenuated rate of the IC increases obviously with the enhance of electron irradiation fluence when the IB is the same. Moreover, the attenuated rate of the IC increases slight with the rise of the IB when the electron irradiation fluence is the same. When the supply voltage is 5.0 V (RL = 1.5 kΩ) and the IB is 4.0 mA, the voltage magnetic sensitivity (SV) of the SMST occurs attenuate after irradiation. The attenuated rate of the SV increases with the enhance of electron irradiation fluence.