Mohamed H. Mussa

Dr. Mohamed H. Mussa

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ASAhmad Sharafati
Ahmad Sharafati
MASOUD HAGHBINMASOUD HAGHBIN
MASOUD HAGHBIN
Mohammed AldlemyMohammed Aldlemy
Mohammed Aldlemy
MMMohamed H. Mussa
Mohamed H. Mussa
Ahmed W. Al ZandAhmed W. Al Zand
Ahmed W. Al Zand
ZYZaher Mundher Yaseen
Zaher Mundher Yaseen
High-strength concrete (HSC) is highly applicable to the construction of heavy structures. However, shear strength (Ss) determination of HSC is a crucial concern for structure designers and decision makers. The current research proposes the novel models based on the combination of adaptive neuro-fuzzy inference system (ANFIS) with several meta-heuristic optimization algorithms, including ant colony optimizer (ACO), differential evolution (DE), genetic algorithm (GA), and particle swarm optimization (PSO), to predict the Ss of HSC slender beam. The proposed models were constructed using several input combinations incorporating several related dimensional parameters such as effective depth of beam (d), shear span (a), maximum size of aggregate (ag), compressive strength of concrete (fc), and percentage of tension reinforcement (ρ). To assess the impact of the non-homogeneity of the dataset on the prediction result accuracy, two possible modeling scenarios, (i) non-processed (initial) dataset (NP) and (ii) pre-processed dataset (PP), are inspected by several performance indices. The modeling results demonstrated that ANFIS-PSO hybrid model attained the best prediction accuracy over the other models and for the pre-processed input parameters. Several uncertainty analyses were examined (i.e., model, variables, and data), and results indicated predicting the HSC shear strength was more sensitive to the model structure uncertainty than the input parameters.

15 June 2021 in Materials
Verified
Journal Article
Open access
PDF file
MMMohamed H. Mussa
Mohamed H. Mussa
NRNoor Azim Mohd Radzi
Noor Azim Mohd Radzi
RHRoszilah Hamid
Roszilah Hamid
AMAzrul A. Mutalib
Azrul A. Mutalib
The study aims to investigate the fire performance of reinforced concrete (RC) slab fabricated from high volume fly ash inclusion with nano-silica (HVFANS) under ISO 834 load curve. The HVFANS concrete slab with dimensions of 1850 mm × 1700 mm × 200 mm was tested via an electrical furnace under an exposing temperature of 1100 °C for 120 min. The slab behaviour was evaluated in terms of residual compressive strength, temperature distribution along its thickness, spalling, and cracks. The results revealed that the slab was capable of maintaining 62.19% of its original compressive strength at room temperature after exposure to the above temperature. Moreover, the distribution of temperature revealed that the temperature of concrete cover and bottom reinforcement was less than 300 °C with a maximum spalling depth of 11 mm within the temperature range of 680 to 840 °C. Furthermore, the thermal conductivity index (K) of the HVFANS concrete was determined, and results indicated that thermal conductivity equalled 0.35 W/mK which is considered low, as compared with other concretes tested in current and previous studies.

31 July 2024 in Fibers
Verified
Journal Article
Open access
PDF file
MMMohamed H. Mussa
Mohamed H. Mussa
AMAzrul A. Mutalib
Azrul A. Mutalib
HHHong Hao
Hong Hao
This study aims to investigate the behaviour of reinforced concrete (RC) beams strengthened by Carbon Fibre-Reinforced Polymer (CFRP) under static and impact loads. A series of RC beams were tested and categorized into four groups, namely, unstrengthened RC beams (B1), RC beams strengthened with a CFRP longitudinal strip in the tension zone (B2), RC beams wrapped with CFRP fabric (B3), and RC beams strengthened with a combination of both CFRP longitudinal strips and wraps (B4). The results show that the average load–displacement capacity of RC beam group (B4) was improved by 84.88% as compared with the unstrengthened beam (B1) under static loads. The dynamic test results demonstrated an increase in the deflection resistance of RC beam group (B4) by −57.89% as compared with unstrengthened RC beam group (B1) under identical drop weights of 1 m. In addition, a collapse failure mode was noticed in the unstrengthened beams, while minor damage was recorded mainly in the case of RC beam group (B4). Furthermore, the numerical analysis conducted using LS-DYNA software (V 971 R6.0.0) proved that the adopted numerical models can efficiently predict the behaviour of RC beams under dynamic loads, with maximum differences reaching up to −12.5% compared with the experimental test results.


24 July 2026 in Buildings
Verified
Journal Article
Open access
PDF file
MMMohamed H. Mussa
Mohamed H. Mussa
AMAzrul A. Mutalib
Azrul A. Mutalib
HHHong Hao
Hong Hao
Reinforced concrete (RC) slabs in buildings and protective structures are vulnerable to repeated low-velocity impacts caused by falling objects, vehicle collisions, industrial accidents, and successive debris strikes. Such repeated impacts can result in cumulative damage, progressive stiffness degradation, and eventual structural failure. Although externally bonded carbon fiber-reinforced polymer (CFRP) sheets have been widely adopted to improve the impact resistance of RC members, their effectiveness under repeated impact loading is often limited by premature debonding, while the contribution of mechanical anchorage systems to mitigating debonding and improving structural performance remains insufficiently understood. Accordingly, this study experimentally and numerically investigates the repeated low-velocity impact behavior of RC two-way slabs strengthened with externally bonded CFRP sheets incorporating boundary and distributed mechanical anchorage configurations. Four slab groups were investigated: unstrengthened control slabs (SL1), CFRP-strengthened slabs (SL2), CFRP-strengthened slabs with boundary anchors only (SL3), and CFRP-strengthened slabs with distributed anchors across the entire slab area (SL4). Repeated impact tests were conducted using a 92 kg drop weight released from progressively increasing heights until failure. The outcomes showed that strengthening of RC slab with CFRP sheets significantly improved the impact resistance at a 1.50 m drop height by reducing the residual displacement, crater diameter, and indentation depth by up to 67%, 55%, and 70%, respectively, compared with the control slabs. The incorporation of mechanical anchors further delayed premature CFRP debonding, maintained the CFRP–concrete bond, and enhanced the structural response, achieving maximum reductions of 77%, 63%, and 85%, respectively. Furthermore, the anchored slabs withstood repeated impacts from a 2.50 m drop height, whereas both the control and unanchored CFRP-strengthened slabs failed at a 2 m drop height. The developed finite element model accurately captured the structural response, CFRP debonding, anchorage failure, and damage evolution of the RC slabs, with good agreement between the numerical predictions and the experimental observations in terms of failure patterns, damage characteristics, and residual displacements. The proposed strengthening strategy and validated numerical model provide a reliable framework for assessing the effectiveness of different mechanical anchorage configurations and predicting the progressive failure behavior of CFRP-strengthened RC slabs subjected to repeated low-velocity impacts.

22 October 2026 in Construction Materials
Verified
Journal Article
Open access
PDF file
MMMohamed H. Mussa
Mohamed H. Mussa
Self-compacting concrete (SCC) is widely used in reinforced concrete structures, yet its residual structural behaviour after fire exposure remains insufficiently understood, particularly under the combined effects of mixture composition, heating rate, and boundary restraint. This study experimentally investigated reinforced SCC beams incorporating fine-to-coarse aggregate (F/C) ratios of 0.90 (SCC-L), 1.00 (SCC-R), and 1.10 (SCC-H). A total of 90 beams were tested at ambient temperature and after exposure to 300 and 500 °C using heating rates of 20 and 30 °C/min under simply supported and restrained-end conditions. Residual ultrasonic pulse velocity (UPV) measurements and four-point flexural tests were conducted. The ambient simply supported reference beams had ultimate loads of 11.2, 11.8, and 10.7 kN and first crack loads of 4.95, 5.20, and 4.50 kN for SCC-L, SCC-R, and SCC-H, respectively. Exposure temperature was the dominant factor governing deterioration, while higher heating rates accelerated thermal damage. At 500 °C and 30 °C/min, simply supported beams retained 66.95–78.50% of their ambient ultimate loads, whereas first crack loads decreased to 36.54–60.00% of their corresponding ambient- temperature values. SCC-H consistently exhibited the highest retention of residual mechanical and structural properties. End restraint increased the residual ultimate load by up to 21.52% and first crack load by up to 89.47% relative to simply supported beams with the same mixture, exposure temperature, and heating rate. The developed empirical model showed a good fit to the experimental ultimate flexural loads (R2 = 0.9637) within the investigated parameter ranges. The results demonstrate that mixture composition and boundary restraint significantly influence post-fire performance, while UPV provides a reliable indicator of residual structural condition.