Nuzhet Nihaar Nasir Ahamed

Ms. Nuzhet Nihaar Nasir Ahamed

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2018 in Chemengineering
Verified
Journal Article
Open access
PDF file
Kalathur SanthanamKalathur Santhanam
Kalathur Santhanam
NANuzhet Nihaar Nasir Ahamed
Nuzhet Nihaar Nasir Ahamed
With the increasing utilization of fossil fuels in today’s technological world, the atmosphere’s concentration of greenhouse gases is increasing and needs to be controlled. In order to achieve this goal, it is imperative to have sensors that can provide data on the greenhouse gases in the environment. The recent literature contains a few publications that detail the use of new methods and materials for sensing these gases. The first part of this review is focused on the possible effects of greenhouse gases in the atmosphere, and the second part surveys the developments of sensors for greenhouse gases with coverage on carbon nano-materials and composites directed towards sensing gases like CO2, CH4, and NOx. With carbon dioxide measurements, due consideration is given to the dissolved carbon dioxide gas in water (moisture). The density functional calculations project that Pd-doped single-walled carbon nanotubes are ideal for the development of NOx sensors. The current trend is to make sensors using 3D printing or inkjet printing in order to allow for the achievement of ppb levels of sensitivity that have not been realized before. This review is to elaborate on the need for the development of greenhouse gas sensors for climatic usage by using selected examples.

30 June 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
FFFarzad Forouzandeh
Farzad Forouzandeh
NANuzhet Nihaar Nasir Ahamed
Nuzhet Nihaar Nasir Ahamed
MHMeng-Chun Hsu
Meng-Chun Hsu
JWJoseph P. Walton
Joseph P. Walton
RFRobert Frisina
Robert Frisina
David BorkholderDavid Borkholder
David Borkholder
Reservoir-based drug delivery microsystems have enabled novel and effective drug delivery concepts in recent decades. These systems typically comprise integrated storing and pumping components. Here we present a stand-alone, modular, thin, scalable, and refillable microreservoir platform as a storing component of these microsystems for implantable and transdermal drug delivery. Three microreservoir capacities (1, 10, and 100 µL) were fabricated with 3 mm overall thickness using stereolithography 3D-printing technology, enabling the fabrication of the device structure comprising a storing area and a refill port. A thin, preformed dome-shaped storing membrane was created by the deposition of parylene-C over a polyethylene glycol sacrificial layer, creating a force-free membrane that causes zero forward flow and insignificant backward flow (2% of total volume) due to membrane force. A septum pre-compression concept was introduced that enabled the realization of a 1-mm-thick septa capable of ~65000 leak-free refill punctures under 100 kPa backpressure. The force-free storing membrane enables using normally-open micropumps for drug delivery, and potentially improves the efficiency and precision of normally-closed micropumps. The ultra-thin septum reduces the thickness of refillable drug delivery devices, and is capable of thousands of leak-free refills. This modular and scalable device can be used for drug delivery in different laboratory animals and humans, as a sampling device, and for lab-on-a-chip and point-of-care diagnostics applications.

4 June 2021 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
FFFarzad Forouzandeh
Farzad Forouzandeh
NANuzhet Nihaar Nasir Ahamed
Nuzhet Nihaar Nasir Ahamed
XZXiaoxia Zhu
Xiaoxia Zhu
PBParveen Bazard
Parveen Bazard
Krittika GoyalKrittika Goyal
Krittika Goyal
David BorkholderDavid Borkholder
David Borkholder
Here we present a 3D-printed, wirelessly controlled microsystem for drug delivery, comprising a refillable microreservoir and a phase-change peristaltic micropump. The micropump structure was inkjet-printed on the back of a printed circuit board around a catheter microtubing. The enclosure of the microsystem was fabricated using stereolithography 3D printing, with an embedded microreservoir structure and integrated micropump. In one configuration, the microsystem was optimized for murine inner ear drug delivery with an overall size of 19 × 13 × 3 mm3. Benchtop results confirmed the performance of the device for reliable drug delivery. The suitability of the device for long-term subcutaneous implantation was confirmed with favorable results of implantation of a microsystem in a mouse for six months. The drug delivery was evaluated in vivo by implanting four different microsystems in four mice, while the outlet microtubing was implanted into the round window membrane niche for infusion of a known ototoxic compound (sodium salicylate) at 50 nL/min for 20 min. Real-time shifts in distortion product otoacoustic emission thresholds and amplitudes were measured during the infusion, demonstrating similar results with syringe pump infusion. Although demonstrated for one application, this low-cost design and fabrication methodology is scalable for use in larger animals and humans for different clinical applications/delivery sites.

19 April 2023 in Electrophoresis
Verified
Journal Article
Closed access
ALAdrian Lomeli‐Martin
Adrian Lomeli‐Martin
NANuzhet Nihaar Nasir Ahamed
Nuzhet Nihaar Nasir Ahamed
VAVinay Abhyankar
Vinay Abhyankar
BLBlanca Lapizco-Encinas
Blanca Lapizco-Encinas

14 December 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
NANuzhet Nihaar Nasir Ahamed
Nuzhet Nihaar Nasir Ahamed
Carlos A. Mendiola-EscobedoCarlos A. Mendiola-Escobedo
Carlos A. Mendiola-Escobedo
VPVíctor H. Pérez-González
Víctor H. Pérez-González
BLBlanca Lapizco-Encinas
Blanca Lapizco-Encinas
There is a rising need for rapid and reliable analytical methods for separating microorganisms in clinical and biomedical applications. Microscale-insulator-based electrokinetic (iEK) systems have proven to be robust platforms for assessing a wide variety of microorganisms. Traditionally, iEK systems are usually stimulated with direct-current (DC) potentials. This work presents a comparison between using DC potentials and using DC-biased alternating-current (AC) potentials in iEK systems for the separation of microorganisms. The present study, which includes mathematical modeling and experimentation, compares the separation of bacterial and yeast cells in two distinct modes by using DC and DC-biased AC potentials. The quality of both separations, assessed in terms of separation resolution (Rs), showed a complete separation (Rs = 1.51) with the application of a DC-biased low-frequency AC signal but an incomplete separation (Rs = 0.55) with the application of an RMS-equivalent DC signal. Good reproducibility between experimental repetitions (<10%) was obtained, and good agreement (~18% deviation) was observed between modeling and experimental retention times. The present study demonstrates the potential of extending the limits of iEK systems by employing DC-biased AC potentials to perform discriminatory separations of microorganisms that are difficult to separate with the application of DC potentials.

9 May 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
NANuzhet Nihaar Nasir Ahamed
Nuzhet Nihaar Nasir Ahamed
CMCarlos A. Mendiola-Escobedo
Carlos A. Mendiola-Escobedo
VPVíctor H. Pérez-González
Víctor H. Pérez-González
BLBlanca Lapizco-Encinas
Blanca Lapizco-Encinas
Electrokinetic (EK) microsystems, which are capable of performing separations without the need for labeling analytes, are a rapidly growing area in microfluidics. The present work demonstrated three distinct binary microbial separations, computationally modeled and experimentally performed, in an insulator-based EK (iEK) system stimulated by DC-biased AC potentials. The separations had an increasing order of difficulty. First, a separation between cells of two distinct domains (Escherichia coli and Saccharomyces cerevisiae) was demonstrated. The second separation was for cells from the same domain but different species (Bacillus subtilis and Bacillus cereus). The last separation included cells from two closely related microbial strains of the same domain and the same species (two distinct S. cerevisiae strains). For each separation, a novel computational model, employing a continuous spatial and temporal function for predicting the particle velocity, was used to predict the retention time (tR,p) of each cell type, which aided the experimentation. All three cases resulted in separation resolution values Rs>1.5, indicating complete separation between the two cell species, with good reproducibility between the experimental repetitions (deviations < 6%) and good agreement (deviations < 18%) between the predicted tR,p and experimental (tR,e) retention time values. This study demonstrated the potential of DC-biased AC iEK systems for performing challenging microbial separations.