Ziyuan Liu

Dr. Ziyuan Liu

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
YGYining Guo
Yining Guo
YWYinhao Wang
Yinhao Wang
RHRan Hao
Ran Hao
XJXiaodan Jiang
Xiaodan Jiang
ZLZiyuan Liu
Ziyuan Liu
XLXuemin Li
Xuemin Li
Purpose . The purpose is to compare the outcomes of implantation of trifocal intraocular lenses (TIOLs) and extended depth of focus (EDOF) intraocular lenses (IOLs). Methods . A comprehensive search of PubMed, Cochrane Library, EMBASE, and ClinicalTrial.gov was conducted in March 2020 to identify relevant studies. A meta‐analysis of the results was performed. Patients implanted with EDOF IOLs or TIOLs in previous studies were included. The primary outcomes of the study were uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), and defocus curve. Results . TIOLs and EDOF IOLs provided comparable binocular UDVA (MD = ‐0.01, 95% CI: ‐0.04, 0.03, logMAR). However, EDOF IOLs provided better UIVA (MD: ‐0.08, 95% CI: ‐0.14, ‐0.01, logMAR) and worse UNVA (MD: 0.10, 95% CI: 0.06, 0.14, logMAR) than TIOLs. Fewer patients achieved spectacle independence after implantation of EDOF IOLs (RR: 0.74, 95% CI: 0.63, 0.87) than after implantation of TIOLs, especially for near vision (RR = 0.82, 95% CI: 0.68, 0.99). There was no statistically significant difference in contrast sensitivity (CS) under photopic or mesopic conditions with both IOLs. Patient satisfaction after implantation of both IOLs was high. Conclusion . EDOF IOLs and TIOLs provide comparable distance vision. However, EDOF IOLs provide better intermediate vision and worse near vision than TIOLs. The advantages of EDOF IOLs over TIOLs in terms of CS, aberrations, and visual disturbance are not significant. Patients are satisfied with both types of IOLs.

12 December 2020
Verified
Conference Paper
Closed access
Hanbin MaHanbin Ma
Hanbin Ma
SSS. Shi
S. Shi
KJK. Jin
K. Jin
DWD. Wang
D. Wang
SHSiyi Hu
Siyi Hu
ANArokia Nathan
Arokia Nathan
We present an active-matrix digital microfluidics platform for bio-sample handling, which demonstrates extension of the ubiquitous and highly-scalable flat-panel technology from displays to bio-applications, and leverage the well-established a-Si thin-film transistor (TFT) manufacturing facilities and excess capacity. The fabricated chip contains 32 × 32 pixels in an active area of 10 cm 2 , which can be individually or simultaneously addressed. Generation and manipulation of liquid droplets at single pixel level with the volume coefficient of variation around 1% is demonstrated. Such performance is substantial improvement over current state-of-the-art (9-pixel resolution and 4% variation). This work opens new possibilities for on-chip in vitro diagnostics in point-of-care testing.

6 December 2024 in Medicine
Verified
Journal Article
Open access
JLJiaxi Li
Jiaxi Li
YLYihe Mm Liu
Yihe Mm Liu
ZLZiyuan Liu
Ziyuan Liu
XLXuemin Li
Xuemin Li
Background: As a common complication of Sjogren syndrome (SS), SS-related dry eye disease (SS-DED) significantly affects the patients’ quality of life. Pro-inflammatory cytokines in tears are widely believed to play a crucial role in the pathogenesis of SS-DED. A systematic literature review with meta-analyses was conducted to provide a quantitative summary of tear cytokine levels in SS-DED compared with non-SS-DED and healthy controls. Methods: The PubMed, Embase, Web of Science, Ovid, and Scopus databases were searched until June 2022. Original case–control studies investigating tear cytokines in SS-DED patients compared with non-SS-DED or healthy individuals were included. Differences of cytokines levels were compared with random-effects standardized mean differences ± 95% confidence intervals calculated as the effect size. Results: A total of 15 articles, 809 subjects (302 for SS-DED, 220 for non-SS-DED, and 287 for healthy controls) were included in the study. SS-DED patients had higher tear levels of interferon-gamma, interleukin (IL)-17, IL-1β, IL-2, IL-4, IL-6, and IL-8 as compared to healthy controls. As for comparison between SS-DED and non-SS-DED group, the levels of IL-12p70, IL-17, IL-4, IL-6, IL-8, and tumor necrosis factor-alpha were significantly higher in SS-DED patients compared with the non-SS-DED group. The level of epidermal growth factor was significantly lower in SS-DED patients compared with both non-SS-DED patients and healthy controls. Conclusion: The findings from this study provide evidence for levels of tear cytokines in SS-DED to become potential diagnostic biomarkers or therapeutic targets. Further studies with a higher number of subjects and improved quality are necessary.

15 January 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
FLFanshu Li
Fanshu Li
KWKehao Wang
Kehao Wang
ZLZiyuan Liu
Ziyuan Liu
In early corneal examinations, the relationships between the morphological and biomechanical features of the cornea were unclear. Although consistent links have been demonstrated between the two in certain cases, these are not valid in many diseased states. An accurate assessment of the corneal biomechanical properties is essential for understanding the condition of the cornea. Studies on corneal biomechanics in vivo suggest that clinical problems such as refractive surgery and ectatic corneal disease are closely related to changes in biomechanical parameters. Current techniques are available to assess the mechanical characteristics of the cornea in vivo. Accordingly, various attempts have been expended to obtain the relevant mechanical parameters from different perspectives, using the air-puff method, ultrasound, optical techniques, and finite element analyses. However, a measurement technique that can comprehensively reflect the full mechanical characteristics of the cornea (gold standard) has not yet been developed. We review herein the in vivo measurement techniques used to assess corneal biomechanics, and discuss their advantages and limitations to provide a comprehensive introduction to the current state of technical development to support more accurate clinical decisions.


28 November 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ZLZiyuan Liu
Ziyuan Liu
KZKaiyun Zhang
Kaiyun Zhang
SGShuang Gao
Shuang Gao
JYJiarui Yang
Jiarui Yang
WQWeiqiang Qiu
Weiqiang Qiu
Purpose: To analyze the correlation between eye movements and asthenopia so as to explore the possibility of using eye-tracking techniques for objective assessment of asthenopia. Methods: This prospective observational study used the computer visual syndrome questionnaire to assess the severity of asthenopia in 93 enrolled college students (age 20–30) who complained about asthenopia. Binocular accommodation and eye movements during the reading task were also examined. The correlations between questionnaire score and accommodation examination results and eye movement parameters were analyzed. Differences in eye movement parameters between the first and last reading paragraphs were compared. The trends in eye movement changes over time were observed. Results: About 81.7% of the subjects suffered from computer visual syndrome. Computer visual syndrome questionnaire total score was positively correlated with positive relative accommodation (p < 0.05). In the first reading paragraph, double vision was positively correlated with unknown saccades (all p < 0.05). Difficulty focusing at close range was positively correlated with total fixation duration, total visit duration, and reading speed (all p < 0.05). Feeling that sight was worsening was positively correlated with regressive saccades (p < 0.05). However, visual impairment symptoms were not significantly correlated with any accommodative function. In a total 20 min reading, significantly reduced eye movement parameters were: total fixation duration, fixation count, total visit duration, visit count, fixation duration mean, and reading speed (all p < 0.01). The eye movement parameters that were significantly increased were: visit duration mean and unknown saccades (all p < 0.001). Conclusion: Eye tracking could be used as an effective assessment for asthenopia. Among the various eye movement parameters, a decrease in fixation duration and counts may be one of the potential indicators related to asthenopia.