Kai Jin

Kai Jin

Auto-generated profile, based on publicly available information

Kai Jin

Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 June 2021 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
KJKai Jin
Kai Jin
CHChenxuan Hu
Chenxuan Hu
SHSiyi Hu
Siyi Hu
CHChengyou Hu
Chengyou Hu
JLJinhua Li
Jinhua Li
Hanbin MaHanbin Ma
Hanbin Ma
In digital microfluidics, droplet generation is a fundamental operation for quantitative liquid manipulation. The generation of well-defined micro-droplets on a chip with restricted device geometries has become a real obstacle for digital microfluidics platforms to be used in parallel for in vitro diagnostic applications. Here, we propose a “one-to-three” droplet splitting technique that is able to generate sub-microlitre droplets beyond the “well-known” geometry limit in electrowetting-on-dielectric digital microfluidics. Accordingly, we realized an on-chip magnetic bead chemiluminescence immunoassay for parallel detection with the “one-to-three” technique. With the help of the generated micro droplets, we were able to retain the magnetic beads by a significantly reduced magnetic force. We have shown the detection of five B-type natriuretic peptide analyte samples on a single chip for around 10 minutes. The correlation coefficient of the calibration curve was 0.9942, and the detection limit was lower than 5 pg mL−1.

12 December 2020
Verified
Conference Paper
Closed access
Hanbin MaHanbin Ma
Hanbin Ma
SSS. Shi
S. Shi
KJK. Jin
K. Jin
DWD. Wang
D. Wang
SHSiyi Hu
Siyi Hu
ANArokia Nathan
Arokia Nathan
We present an active-matrix digital microfluidics platform for bio-sample handling, which demonstrates extension of the ubiquitous and highly-scalable flat-panel technology from displays to bio-applications, and leverage the well-established a-Si thin-film transistor (TFT) manufacturing facilities and excess capacity. The fabricated chip contains 32 × 32 pixels in an active area of 10 cm 2 , which can be individually or simultaneously addressed. Generation and manipulation of liquid droplets at single pixel level with the volume coefficient of variation around 1% is demonstrated. Such performance is substantial improvement over current state-of-the-art (9-pixel resolution and 4% variation). This work opens new possibilities for on-chip in vitro diagnostics in point-of-care testing.

1 May 2023 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
CHChenxuan Hu
Chenxuan Hu
KJKai Jin
Kai Jin
Hanbin MaHanbin Ma
Hanbin Ma
High-efficient droplet generation is crucial in microfluidics platforms in bio-applications. Among the microfluidic techniques, digital microfluidics, although with the capability of programmatically manipulating the droplets, is less effective in high-throughput droplets generation. In this Letter, a continuous “one-to-two” droplet generation strategy on digital microfluidics platform is achieved with an exponential generation efficiency, while overcoming the restriction on the droplet geometries (aspect ratio) in a wide range. An energy-based sub-droplet generation model is also proposed, as an expansion to the previous Laplace pressure-based geometrical model. The electrical parameters are taken into computing the sub-droplet generation on digital microfluidics from the aspect of energy. The proposed continuous “one-to-two” droplet generation strategy can generate sub-droplets with a minimized electrodes' number while with a higher energy input in each operation. The exponential efficiency will open the era for high-throughput droplets' application developments in digital microfluidics.

1 August 2019 in Analytica Chimica Acta
Verified
Journal Article
Closed access
KJKai Jin
Kai Jin
SHSiyi Hu
Siyi Hu
YSYang Su
Yang Su
CYChao Yang
Chao Yang
JLJinhua Li
Jinhua Li
Hanbin MaHanbin Ma
Hanbin Ma

14 April 2020 in SAE International Journal of Advances and Current Practices in Mobility
Verified
Journal Article
Closed access
CPChandan Paul
Chandan Paul
KJKai Jin
Kai Jin
NFNavin Fogla
Navin Fogla
KRKevin Roggendorf
Kevin Roggendorf
SWSyed Wahiduzzaman
Syed Wahiduzzaman
Numerical simulation of in-cylinder processes can significantly reduce the development and refinement costs of engines. While it can be argued that higher fidelity models improve accuracy of prediction, it comes at the expense of high computational cost. In this respect, a 3D analysis of in-cylinder processes may not be feasible for evaluating large number of design and operating conditions. The situation can be more foreboding for transient simulations. In the current work a phenomenological combustion modeling approach is explored that can be implemented in a lower fidelity modeling framework and can approach the accuracy of higher dimensional models with significant reduction in computational cost. The proposed model uses transported probability density function (tPDF) method within a 0D framework to provide a computationally efficient solution while capturing the essential physics of in-cylinder combustion. Scalar mixing is accounted for by a modified Euclidean Minimum Spanning Tree (EMST) mixing model. A new model has been formulated to calculate the mixing timescale using the velocity-composition-frequency (VCF) tPDF method. Numerical comparisons have been performed for two engines: one with a 3D-CFD simulated diesel engine to compare the in-cylinder composition and thermal stratification, and one with a diesel engine where measured data is available over a range of operating conditions encompassing a range of speed, load, and exhaust-gas recirculation (EGR). A 42-species chemical mechanism including thermal NO is used to represent the gas-phase chemistry. The proposed 0D-VCF model predicted pressure, heat-release-rate, equivalence-ratio vs temperature distribution, and NOx are compared to the 3D-CFD data, as well as to the experimentally measured data. The proposed model was able to capture the 3D-CFD trend of equivalence-ratio vs temperature distribution at different crank-angle degrees quite accurately. The 0D-VCF model computed pressure and heat-release-rate along with the NOx showed reasonable agreement with the experiment. In summary, the proposed 0D numerical model has the potential to provide a computationally less expensive alternative to a 3D numerical simulation for estimating engine performance and engine-out emission quantities when transient or large number of operating points are to be simulated.

4 May 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
KJKai Jin
Kai Jin
ZYZhicheng Yang
Zhicheng Yang
ADAnqi Ding
Anqi Ding
RWRong Wang
Rong Wang
YMYifan Ma
Yifan Ma
HZHu Zhou
Hu Zhou
Single-cell proteomics (SCP) remains constrained by slow sample preparation and background interference in low-input, multistep workflows, limiting its broader practical use in complex biological samples. Here we report AM-DMF-SCP-pro, a streamlined active-matrix digital microfluidic workflow that enables rapid on-chip lysis and digestion in 6 nL droplets within a closed nanolitre-confined microenvironment. AM-DMF-SCP-pro reduces total sample-preparation time to as little as 30 min, including a 15 min digestion step, while maintaining quantitative reproducibility and digestion performance. Systematic optimization of mass spectrometry acquisition and nanolitre-scale digestion conditions enables deeper, more sensitive and lower-background proteome profiling from ultra-low peptide inputs. In murine tumor samples, AM-DMF-SCP-pro reliably resolves immune and tumor compartments, identifies treatment-associated tumor cell states and enables quantitative analysis of neutrophil-associated proteomic signatures. These results establish AM-DMF-SCP-pro as a practical workflow for rapid, low-background single-cell proteome profiling in complex biological samples.