In this study, graphene is used as a photothermal material, which is added to the SiO2 superhydrophobic solution treated with fluorine silane, and then sprayed on the copper plate surface to prepare a new type of photothermal superhydrophobic surface with contact angles up to 160.5° and 159.8°. Under the conditions of natural convection, the effects of photothermal superhydrophobic surfaces on droplet condensation, freezing, and frost growth are investigated in different environments. The results show that the photothermal superhydrophobic surface can not only delay the freezing of surface droplets, prolong the freezing time of droplets, and reduce the thickness of the frost layer, but also allow for the rapid removal of droplets under near-infrared (NIR) irradiation. If the droplet is irradiated by an infrared laser emitter while the cooling system is still turned on, the internal temperature of the droplet will always be higher than the crystallization temperature under the illumination intensity of 2 W/cm2, and the droplets will not freeze. With the extension of irradiation time, the droplet will evaporate, and the volume of the droplet will decrease. On the basis of summarizing and evaluating the study on the anti-icing performance of superhydrophobic surfaces and the properties of photothermal materials, a new research direction regarding the anti-icing of fan blade surfaces was established. This kind of surface combines the photothermal capabilities of light absorption materials with the micro- and nanostructure of the superhydrophobic surface to improve the anti-icing capability of wind turbine blade surfaces in difficult conditions.
A solar heat pump based on the photovoltaic photothermal (PV/T) module is a new technology that can improve the photovoltaic efficiency and recovery of waste heat in photovoltaic conversion. The comprehensive efficiency of a system can thus be greatly improved. At present, there is little research on the simulation of a solar heat pump based on the Simulink 2018 software. In this paper, PV/T modules are modeled and simulated using the Simulink software based on the typical meteorological parameters in Beijing city during summer and winter conditions. Considering the system characteristics of a simultaneous operation, the models of all components such as the compressor, condenser, evaporator, expansion valve, and heat storage tanks contained in a system are established based on the system’s working principle, energy conservation equations, and some empirical formulas and then simulated. As PV/T modules are the key influencing factor for system performance, the model and simulation process are introduced in detail in this paper. The results show that the surface temperature of PV/T modules under different operating conditions are all significantly lower than that of ordinary photovoltaic panels. The average temperature of PV/T modules is only 15.2 °C, which is 20.2 °C lower than that of ordinary panels under summer conditions, and the average temperature of PV/T modules is only 0.5 °C, 17.8 °C lower than that of ordinary panels under winter conditions. The average photoelectric efficiency can be improved by 15.4% and 8.9%. And, the temperature change amplitude of PV/T modules is lower, which weakens the temperature fluctuation of the modules. The photovoltaic efficiency is therefore further increased. As a result, the power generation and photovoltaic efficiency are both improved significantly.
The solar heat pump system based on photovoltaic photothermal (PV/T) modules is a new technology that integrates photovoltaics and heat reutilization. It can improve the efficiency of photovoltaic conversion and recovery the remaining heat generated during the photoelectric conversion process, thereby improving the comprehensive efficiency of the whole system. Simulink software is a visual simulation tool, which has the advantages of strong applicability, clear simulation structure and calculation process. The design of its graphical programming greatly simplifies the user modeling process and allows for direct viewing of results, therefore improving the simulation efficiency. At present, there is little research on simulation of solar heat pump systems with PV/T modules based on Simulink software. In this paper, the mathematical models of each component contained in the PV/T solar heat pump system were established based on the system working principle, energy conservation equations and some empirical formulas, and then the operation of the system was simulated by the Simulink software. Due to the operation characteristic of PV/T modules is the key influencing factor for the whole system performance, the model and simulation process for PV/T modules were introduced in detail. The results showed that the surface temperature of PV/T modules under different operating conditions was significantly lower than that of ordinary photovoltaic panels, and the temperature change amplitude was lower. As results, the power generation and photovoltaic conversion efficiency were significantly improved.