Basiony Shehata Atia

Mr. Basiony Shehata Atia

Electrical Engineering, Aswan University, Aswān, Egypt
orcid
PhD Student at Aswan University

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 April 2023 in Axioms
Verified
Journal Article
Open access
PDF file
Mohamed Metwally MahmoudMohamed Metwally Mahmoud
Mohamed Metwally Mahmoud
Basiony Shehata AtiaBasiony Shehata Atia
Basiony Shehata Atia
YEYahia Esmail
Yahia Esmail
Sid Ahmed El Mehdi ARDJOUNSid Ahmed El Mehdi ARDJOUN
Sid Ahmed El Mehdi ARDJOUN
NANoha Anwer
Noha Anwer
SAshazly Ahmed
shazly Ahmed
In recent modern power systems, the number of renewable energy systems (RESs) and nonlinear loads have become more prevalent. When these systems are connected to the electricity grid, they may face new difficulties and issues such as harmonics and non-standard voltage. The proposed study suggests the application of a whale optimization algorithm (WOA) based on a fractional-order proportional-integral controller (FOPIC) for unified power quality conditioner (UPQC) and STATCOM tools. These operate best with the help of their improved control system, to increase the system’s reliability and fast dynamic response, and to decrease the total harmonic distortion (THD) for enhancing the power quality (PQ). In this article, three different configurations are studied and assessed, namely: (C1) WOA-based FOPIC for UPQC, (C2) WOA-based FOPIC for STATCOM, and (C3) system without FACTS, i.e., base case, to mitigate the mentioned drawbacks. C3 is also considered as a base case to highlight the main benefits of C1 and C2 in improving the PQ by reducing the %THD of the voltage and current system and improving the systems’ voltage waveforms. With C2, voltage fluctuation is decreased by 98%, but it nearly disappears in C1 during normal conditions. Additionally, during the fault period, voltage distortion is reduced by 95% and 100% with C2 and C1, respectively. Furthermore, when comparing C1 to C2 and C3 under regular conditions, the percentage reduction in THD is remarkable. In addition, C1 eliminates the need for voltage sag, and harmonic and current harmonic detectors, and it helps to streamline the control approach and boost control precision. The modeling and simulation of the prepared system are performed by MATLAB/Simulink. Finally, it can be concluded that the acquired results are very interesting and helpful in the recovery to the steady state of wind systems and nonlinear loads, thereby increasing their grid connection capabilities.

18 January 2023 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Open access
PDF file
Mohamed Metwally MahmoudMohamed Metwally Mahmoud
Mohamed Metwally Mahmoud
Basiony Shehata AtiaBasiony Shehata Atia
Basiony Shehata Atia
YEYahia M. Esmail
Yahia M. Esmail
Mohit BajajMohit Bajaj
Mohit Bajaj
DWDaniel Eutyche Mbadjoun Wapet
Daniel Eutyche Mbadjoun Wapet
AAAbdel-Moamen M. Abdel-Rahim
Abdel-Moamen M. Abdel-Rahim
Several advantages make wind-driven permanent magnet synchronous generators (PMSGs) very promising in the wind energy market, especially their fault ride-through capabilities. With the high penetration levels of today, both the grid and wind power (WP) systems are being affected by each other. Due to grid faults, the DC-bus in PMSG systems typically experiences overvoltage, which can negatively affect the generator parameters and trip the system. However, advancements in power electronics, control systems, fault limiters, FACTS, and energy storage technology make it possible to find and design satisfactory solutions and approaches. The most recent FRTC-improving techniques are mainly modified or external techniques based on controllers in PMSG-based WP. This paper evaluates the in-depth schemes of FRTC, introducing the underlying theory and traits of the different approaches to highlight the advantages and drawbacks of each. Five scenarios of DC-link voltage under zero-grid voltage are carried out by using the MATLAB SIMULINK program to assess the FRTC methods. This study shows that external device-based approaches can be efficient, but some of them are expensive, thus updated controller methods are recommended to cut costs. Research findings of this study are expected to support the deployment of FRTC technologies, as well as provide valuable input into WP research on grid integration.

17 November 2022 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Open access
PDF file
Mohamed Metwally MahmoudMohamed Metwally Mahmoud
Mohamed Metwally Mahmoud
YEYahia M. Esmail
Yahia M. Esmail
Basiony Shehata AtiaBasiony Shehata Atia
Basiony Shehata Atia
OKOmar Makram Kamel
Omar Makram Kamel
Kareem AboRasKareem AboRas
Kareem AboRas
DWDaniel Eutyche Mbadjoun Wapet
Daniel Eutyche Mbadjoun Wapet
The voltage quality (VQ) index has become a significant measure of recent power system stability. The integration of photovoltaic (PV) systems plus smart home loads (SHLs) at low voltage levels (LVLs) has resulted in various issues such as harmonics rise and voltage instabilities as a result of faults and systems nonlinearity. In this work, a dynamic voltage resistor (DVR) is implemented to enhance VQ, and its dynamic performance hinges on its control system ability. To enhance the DVR’s control system, for surpassing nonstandard voltage with a quick response and harmonics reduction at LVL under harsh operating events, an optimal controller design using the Harris Hawks algorithm (HHA) is proposed. To verify the value of the suggested solution, the hard operating events (voltage sag, voltage swell, fluctuating voltage, and imbalanced voltage) are examined and assessed. To show the effectiveness of the HHA technique, a comparison of the % total harmonic distortion (THD) reductions achieved by the suggested and conventional controllers of DVR is conducted for the scenarios under study. Moreover, the suggested controller stability is analyzed and assessed using Lyapunov’s function. The benefits of the optimized controller system are inferred from the results, including their robustness, simplicity, efficient harmonic rejection, minimal tracking error, quick response, and sinusoidal reference track. The results of the simulation show that the DVR’s optimized controller is efficient and effective in maintaining a voltage at the needed level with low THD, safeguarding the sensitive load as expected, and showing a noticeable improvement in voltage waveforms. The mathematical modeling of HHA, PV system, DVR, and SHLs are all verified using MATLAB\Simulink.

16 December 2022 in Processes
Verified
Journal Article
Open access
PDF file
Mohamed Metwally MahmoudMohamed Metwally Mahmoud
Mohamed Metwally Mahmoud
Basiony Shehata AtiaBasiony Shehata Atia
Basiony Shehata Atia
AAAlmoataz Abdelaziz
Almoataz Abdelaziz
NNNoura Nouraldin
Noura Nouraldin
Wind generators have attracted a lot of attention in the realm of renewable energy systems, but they are vulnerable to harsh environmental conditions and grid faults. The influence of the manta ray foraging optimizer (MRFO) on the dynamic performance of the two commonly used variable speed wind generators (VSWGs), called the permanent magnet synchronous generator (PMSG) and doubly-fed induction generator (DFIG), is investigated in this research article. The PMSG and DFIG were exposed to identical wind speed changes depending on their wind turbine characteristics, as well as a dangerous three-phase fault, to evaluate the durability of MRFO-based wind side controllers. To protect VSWGs from hazardous gusts and obtain the optimum power from incoming wind speeds, we utilized a pitch angle controller and optimal torque controller, respectively, in our study. During faults, the commonly utilized industrial approach (crowbar system) was exclusively employed to aid the studied VSWGs in achieving fault ride-through (FRT) capability and control of the DC link voltage. Furthermore, an MRFO-based PI controller was used to develop a crowbar system. The modeling of PMSG, DFIG, and MRFO was performed using the MATLAB/Simulink toolbox. We compared performances of PMSG and DFIG in reference tracking and resilience against changes in system parameters under regular and irregular circumstances. The effectiveness and reliability of the optimized controllers in mitigating the adverse impacts of faults and wind gusts were demonstrated by the simulation results. Without considering the exterior circuit of VSWGs or modifying the original architecture, MRFO-PI controllers in the presence of a crowbar system may help cost-effectively alleviate FRT concerns for both studied VSWGs.

2 April 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
Basiony Shehata AtiaBasiony Shehata Atia
Basiony Shehata Atia
Mohamed Metwally MahmoudMohamed Metwally Mahmoud
Mohamed Metwally Mahmoud
IEI. M. Elzein
I. M. Elzein
AAAbdelmoamen Ahmed
Abdelmoamen Ahmed
AAAbdulaziz Alkuhayli
Abdulaziz Alkuhayli
SSSalma Abdelaal Shaaban
Salma Abdelaal Shaaban
An optimization technique, the Kepler optimizer (KO), is presented to enable permanent magnet synchronous wind generators (PMSWG) to run safely under faults and to accomplish the goal of low-carbon efficient power delivery and sustainable development. Utility companies are struggling, which is preventing the increase in wind penetration, in spite of the grid incorporation of PMSWG. One of these undisputed concerns is the grid-side voltage dip (VD) and swell (VS) at the PCC. Converters and DCL capacitors are particularly vulnerable to PCC nonstandard voltages because of an imbalance in the DCL input–output powers. Because of this, it is essential to provide WF-GCs to support grid operations, and developing techniques to realize FRTCs has become a crucial GC need. Installing an industrial braking chopper (BC) across the DCL is the suggested technique, due to its effectiveness and low price. In addition, a new KO-based control system for BC is used to enhance its effectiveness. Four situations were examined to assess and analyze the proposed control system regarding the transient response of the system. These situations exposed the investigated system to an irregular grid condition: without BC, with BC controlled by a hysteresis controller, and with BC controlled by KO-based PI (proposed) at (a) 100% VD, (b) 70% VD, (c) 30% VD, and (d) 20% VS. To verify the advantages and efficacy of the suggested control systems in the examined circumstances, MATLAB/SIMULINK was utilized. The simulation findings confirmed the feasibility of the suggested system as a whole and the control structures in suppression of all parameter transient changes, while also achieving FRTC. Furthermore, maintaining a steady DCL voltage serves as an advantage that would lengthen the electrical converters’ lifetime and shorten the time that the unit would be turned off if it happens to fail.

25 January 2021 in Energy Systems Research
Verified
Journal Article
Open access
PDF file
MMM.M. Mohamed
M.M. Mohamed
Basiony Shehata AtiaBasiony Shehata Atia
Basiony Shehata Atia
KMK.R. Mohamed
K.R. Mohamed
AMA. Mohamed
A. Mohamed
EAE. Abdallah
E. Abdallah
AAAbdel-Rahim Abdel-Moamen
Abdel-Rahim Abdel-Moamen
Stable operation of permanent-magnet synchronous generator-based wind turbines (PMSG-WTs) is a challenging and complicated objective. Dealing with the hard situations and complex operations of the PMSG-WTs has recently become a hot issue in modern power systems. The abilities of PMSG-WT to ride over faults and operate at maximum power point (MPP) are the most critical requirements for national grid regulations. To maintain the system's reliability, PMSG-WT should remain linked to the grid during normal and abnormal conditions. Furthermore, PMSG-WT has the potential to inject reactive power during failures. It produces active and reactive power to maintain grid voltage immediately after the fault is cleared. This research uses MATLAB/Simulink to investigate the operation at MPP during wind speed changes and FRT capability during three-phase fault of PMSG-WT to validate the support of grey wolf optimizer (GWO)-based PI controllers at the wind side converter. The findings reveal that, when PMSG-WT is exposed to a fault, active and reactive power react in a complementary manner, i.e., active power to the grid drops, and injected reactive power rises to stabilize the system. While during wind speed changes the system achieves MPP operation using an optimal torque control strategy, and the output power follows the wind variations.