Mohamed Metwally Mahmoud

Dr. Mohamed Metwally Mahmoud

Aswan University, Aswān, Egypt
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2023 in IEEE Access
Verified
Journal Article
Open access
Nagwa .F IbrahimNagwa .F Ibrahim
Nagwa .F Ibrahim
Mohamed Metwally MahmoudMohamed Metwally Mahmoud
Mohamed Metwally Mahmoud
ATAli M. H. Al Thaiban
Ali M. H. Al Thaiban
ABAbdulwasa Bakr Barnawi
Abdulwasa Bakr Barnawi
Zakaria M.S ElbarbaryZakaria M.S Elbarbary
Zakaria M.S Elbarbary
HAHany Abdelfattah
Hany Abdelfattah
The expanding use of photovoltaics (PV) as a green energy resource has been rising in these years, mostly due to the possibility of being incorporated with traditional power systems, to meet the world’s energy needs and reduce carbon emissions. However, providing green electricity from this renewable generator is frequently vulnerable to power quality (PQ) disruptions resulting from the PV’s intermittent nature and other factors associated with the electric grid, power converters, and linked loads. These disruptions need to be reduced to keep the investigated system’s PQ from deteriorating. The investigated system includes PV, DC-DC, and DC-AC converters, filter, power grid, and control schemes. If the DC-DC converter is not managed, a deviation from the maximum power point (MPP) extrapolated from the PV system will take place. In order to maximize the energy harvested from the PV system by managing the DC-DC converter, this research developed two MPP tracking (MPPT) algorithms: artificial neural networks (ANN) and cuckoo search (CS). Additionally, a design and implementation for a shunt active power filter (LCL) using genetic algorithm and GRG is provided to lower the injected total harmonic distortion (THD) and thereby enhance the PQ. To achieve the smallest size of the LCL components, the generalized reduced gradient (GRG) was the best compared to genetic algorithms GA. The results of the simulation showed that ANN performed better at tracking maximum power than CS. With the designed LCL, the THD is reduced by 99.78% compared to without a filter. To verify the simulation’s findings, a practical configuration is implemented.

31 October 2022 in International Journal of Modelling and Simulation
Verified
Journal Article
Closed access
Mohamed Metwally MahmoudMohamed Metwally Mahmoud
Mohamed Metwally Mahmoud
The creation of optimization methods is relatively common and popular today for solving issues in engineering areas. In this paper, a new wild horse optimizer (WHO) method is adopted to design an optimal controller for a permanent-magnet synchronous generator (PMSG)-based wind turbine system (WTS). A control method consisting of two current control loops of the optimized controller is proposed for the control of the machine-side converter. The dynamic performance of PMSG can be improved during the different normal and abnormal conditions through effective tuning of the PI controller gains which enhances the overall response of the system parameters. This enhancement consequently results in the realization of the maximal power tracking during wind speed changes and the fault ride-through capability during faults and large-signal events. Furthermore, the power fluctuations due to the incoming wind speed variants can be smoothed by using the suggested controller. In addition, the proposed controller system employs an optimal torque control method and braking chopper system to help in achieving such tasks. MATLAB simulations of a 1.5 MW PMSG-WTS have been carried out and compared with the Ziegler Nichols-based PI controller in order to validate the feasibility and efficacy of the proposed controller.

26 April 2023 in Axioms
Verified
Journal Article
Open access
PDF file
Mohamed Metwally MahmoudMohamed Metwally Mahmoud
Mohamed Metwally Mahmoud
Basiony Shehata AtiaBasiony Shehata Atia
Basiony Shehata Atia
YEYahia Esmail
Yahia Esmail
Sid Ahmed El Mehdi ARDJOUNSid Ahmed El Mehdi ARDJOUN
Sid Ahmed El Mehdi ARDJOUN
NANoha Anwer
Noha Anwer
SAshazly Ahmed
shazly Ahmed
In recent modern power systems, the number of renewable energy systems (RESs) and nonlinear loads have become more prevalent. When these systems are connected to the electricity grid, they may face new difficulties and issues such as harmonics and non-standard voltage. The proposed study suggests the application of a whale optimization algorithm (WOA) based on a fractional-order proportional-integral controller (FOPIC) for unified power quality conditioner (UPQC) and STATCOM tools. These operate best with the help of their improved control system, to increase the system’s reliability and fast dynamic response, and to decrease the total harmonic distortion (THD) for enhancing the power quality (PQ). In this article, three different configurations are studied and assessed, namely: (C1) WOA-based FOPIC for UPQC, (C2) WOA-based FOPIC for STATCOM, and (C3) system without FACTS, i.e., base case, to mitigate the mentioned drawbacks. C3 is also considered as a base case to highlight the main benefits of C1 and C2 in improving the PQ by reducing the %THD of the voltage and current system and improving the systems’ voltage waveforms. With C2, voltage fluctuation is decreased by 98%, but it nearly disappears in C1 during normal conditions. Additionally, during the fault period, voltage distortion is reduced by 95% and 100% with C2 and C1, respectively. Furthermore, when comparing C1 to C2 and C3 under regular conditions, the percentage reduction in THD is remarkable. In addition, C1 eliminates the need for voltage sag, and harmonic and current harmonic detectors, and it helps to streamline the control approach and boost control precision. The modeling and simulation of the prepared system are performed by MATLAB/Simulink. Finally, it can be concluded that the acquired results are very interesting and helpful in the recovery to the steady state of wind systems and nonlinear loads, thereby increasing their grid connection capabilities.

4 February 2023 in Energies
Verified
Journal Article
Open access
PDF file
OMOmar Makram
Omar Makram
AHMED DIABAHMED DIAB
AHMED DIAB
Mohamed Metwally MahmoudMohamed Metwally Mahmoud
Mohamed Metwally Mahmoud
AAAmeena Alsumaiti
Ameena Alsumaiti
Hamdy SultanHamdy Sultan
Hamdy Sultan
Modern electrical power systems now require the spread of microgrids (MG), where they would be operating in either islanded mode or grid-connected mode. An inherent mismatch between loads and sources is introduced by changeable high renewable share in an islanded MG system with stochastic load demands. The system frequency is directly impacted by this mismatch, which can be alleviated by incorporating cutting-edge energy storage technologies and FACTS tools. The investigated islanded MG system components are wind farm, solar PV, Electric vehicles (EVs), loads, DSTATCOM, and diesel power generator. An aggregated EVs model is connected to the MG during uncertain periods of the generation of renewable energy (PV and wind) to support the performance of MGs. The ability to support ancillary services from the EVs is checked. DSTATCOM is used to provide voltage stability for the MG during congestion situations. The MG is studied in three scenarios: the first scenario MG without EVs and DSTATCOM, the second scenario MG without DSTATCOM, and the third scenario MG with all components. These scenarios are addressed to show the role of EVs and DSTATCOM, and the results in the third scenario are the best. The system voltage and frequency profile is the best in the last scenario and is entirely satisfactory and under the range of the IEEE standard. The obtained results show that both EVs and DSTATCOM are important units for improving the stability of modern power grids. The Matlab/Simulink program is considered for checking and validating the dynamic performance of the proposed configuration.

3 November 2023 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Nagwa .F IbrahimNagwa .F Ibrahim
Nagwa .F Ibrahim
Mohamed Metwally MahmoudMohamed Metwally Mahmoud
Mohamed Metwally Mahmoud
HAHashim Alnami
Hashim Alnami
DWDaniel Eutyche Mbadjoun Wapet
Daniel Eutyche Mbadjoun Wapet
Sid Ahmed El Mehdi ARDJOUNSid Ahmed El Mehdi ARDJOUN
Sid Ahmed El Mehdi ARDJOUN
HAH. Abdelfattah
H. Abdelfattah
Solar energy, a prominent renewable resource, relies on photovoltaic systems (PVS) to capture energy efficiently. The challenge lies in maximizing power generation, which fluctuates due to changing environmental conditions like irradiance and temperature. Maximum Power Point Tracking (MPPT) techniques have been developed to optimize PVS output. Among these, the incremental conductance (INC) method is widely recognized. However, adapting INC to varying environmental conditions remains a challenge. This study introduces an innovative approach to adaptive MPPT for grid-connected PVS, enhancing classical INC by integrating a PID controller updated through a fuzzy self-tuning controller (INC-FST). INC-FST dynamically regulates the boost converter signal, connecting the PVS’s DC output to the grid-connected inverter. A comprehensive evaluation, comparing the proposed adaptive MPPT technique (INC-FST) with conventional MPPT methods such as INC, Perturb & Observe (P&O), and INC Fuzzy Logic (INC-FL), was conducted. Metrics assessed include current, voltage, efficiency, power, and DC bus voltage under different climate scenarios. The proposed MPPT-INC-FST algorithm demonstrated superior efficiency, achieving 99.80%, 99.76%, and 99.73% for three distinct climate scenarios. Furthermore, the comparative analysis highlighted its precision in terms of control indices, minimizing overshoot, reducing rise time, and maximizing PVS power output.

20 July 2023 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MAMohamed Awad
Mohamed Awad
Mohamed Metwally MahmoudMohamed Metwally Mahmoud
Mohamed Metwally Mahmoud
ZEZ. M. S. Elbarbary
Z. M. S. Elbarbary
LALoai Mohamed Ali
Loai Mohamed Ali
SFShazly Nasser Fahmy
Shazly Nasser Fahmy
Ahmed I. OmarAhmed I. Omar
Ahmed I. Omar
In recent times, renewable energy systems (RESs) such as Photovoltaic (PV) and wind turbine (WT) are being employed to produce hydrogen. This paper aims to compare the efficiency and performance of PV and WT as sources of RESs to power polymer electrolyte membrane electrolyzer (PEMEL) under different conditions. The study assessed the input/output power of PV and WT, the efficiency of the MPPT controller, the calculation of the green hydrogen production rate, and the efficiency of each system separately. The study analyzed variable irradiance from 600 to 1000 W/m2 for a PV system and a fixed temperature of 25°C, while for the WT system, it considered variable wind speed from 10 to 14 m/s and zero fixed pitch angle. The study demonstrated that the applied controllers were effective, fast, low computational, and highly accurate. The obtained results showed that WT produces twice the PEMEL capacity, while the PV system is designed to be equal to the PEMEL capacity. The study serves as a reference for designing PV or WT to feed an electrolyzer. The MATLAB program validated the proposed configurations with their control schemes.