In distribution networks, time asynchrony exists between the phasor measuring unit (PMU) at both ends of a line, and the effective measurement time of the devices is short, leading to insufficient accuracy in phasor measurements. This paper proposes a fault location method for distribution networks that employ an additional inductance strategy to address the limited location accuracy caused by time asynchrony and the inadequate accuracy of phasor measurement devices. The method enhances the stability and accuracy of phase measurement by connecting an additional inductance after the online circuit breaker, thus extending the effective measurement time. It uses the symmetrical component method to obtain the positive-sequence and negative-sequence networks following a fault. Time asynchrony is treated as an equivalent asynchronous phase angle, which is then applied to the positive and negative-sequence voltage components. The impact of time asynchrony is mitigated by compensating for the phase angle difference using the ratio of the positive-sequence voltage component to the negative-sequence voltage component. This approach provides the fault location function and has improved the accuracy of fault location, which is advantageous for rapid fault repair.
Wind turbines are vulnerable to negative sequence current injection, the conventional automatic reclosing scheme for wind power outgoing lines, since we may inject negative sequence components into the system and reclose it without distinguishing the nature of the fault through rectification. Moreover, reclosing in permanent faults could induce a secondary impact on the system. To solve the above problems, an adaptive reclosing scheme for cross-line faults on double-circuit wind power outgoing lines with shunt reactors is proposed. Firstly, a new tripping strategy and a single-side partial-phase reclosing method are proposed for multiple types of outgoing line faults, while, simultaneously, phase-to-phase coupling loops are established. Secondly, the criteria of fault nature are established based on the fault phase shunt reactor current and fault phase voltage characteristics, and transient faults are rapidly and accurately distinguished from permanent ones according to the criteria. Finally, the theoretical derivation and simulation experiments are conducted on the PSCAD/EMTDC platform to demonstrate that the proposed adaptive reclosing method is applicable to avoid the injection of negative sequence currents into wind turbines. Meanwhile, the success rate of reclosing for wind power outgoing line is significantly improved and the continuity of power transmission on the wind farm(s) is ensured.
The uncertainty of high penetration of renewable energy brings challenges to the safe and stable operation of a power system; the virtual synchronous compensation (VSCOM) can shift the demand and compensate real-time discrepancy between generation and demand, and can improve the active support ability for the power system. This paper proposes a novel capacity allocation strategy using VSCOM for renewable energy stations based on fuzzy constraints. Firstly, the basic framework of the VSCOM is constructed with energy storage and reactive power generator (SVG) unit. Secondly, the inertia and standby capacity requirements of high penetration of renewable energy system are modeled; on this basis, a capacity allocation model of each sub unit of the VSCOM is developed, and the investment economy and stable support needs are considered. Thirdly, the uncertainty set of wind power output is defined based on the historical data to find a decision that minimizes the worst-case expected where the worst case should be taken. Finally, the simulation results show that the proposed optimal sizing strategy can effectively take advantage of stability and economy, and the VSCOM can meet the inertia support demand of 98.6% of a high proportion of renewable energy systems.
The Onshore Wind Power All-DC Generation System (OWDCG) is designed to integrate with renewable energy sources by modifying the grid structure. This adaptation supports the grid infrastructure and addresses the challenges of large-scale wind power AC collection and harmonic resonance during transmission. Crucially, small disturbance stability parameters are essential for ensuring the system’s stable operation. Unlike conventional power systems, the OWDCG exhibits strong coupling between subsystems, accentuating the small disturbance stability issue due to the dynamic nature of its converter control system. The impedance method facilitates the decomposition of such systems into subsystems, offering insights into the destabilization mechanism through the lens of negative impedance contribution. This approach is conducive to conducting small disturbance stabilization analyses. To tackle this issue, the initial step involves deriving the input and output equivalent impedance models of the subsystem, considering the topological structure, control features, and operational dynamics of the OWDCG. Subsequently, the impact of circuit and control parameters on the system’s impedance characteristics and small-disturbance stability is examined through Bode diagrams and Nyquist curves. This analysis identifies critical parameters for small-disturbance stability, guiding the stable operation and parameter optimization of the OWDCG. The analysis highlights that the main control strategies for stability are the Modular Multilevel Converter (MMC) DC voltage control and the inner-loop current control gain. Validation of the theoretical findings is achieved through simulation results using PSCAD/EMTDC.
The application of conventional AC collection for the integration of large-scale renewable energy sources may lead to issues concerning harmonic resonance and reactive power transmission. Conversely, the utilization of an all-DC power generation system for wind power (WDCG) can effectively circumvent such issues. In contrast to the conventional power system, the interdependence among subsystems in the WDCG renders it susceptible to oscillation instability in the presence of minor disturbances. To address this concern, this paper first establishes a small-signal model for the WDCG, and validates the accuracy of this model by comparing it with an electromagnetic transient model based on PSCAD/EMTDC. Secondly, employing the eigenvalue analysis method, the principal oscillation modes of the WDCG are identified, and the state variables strongly correlated with these modes are analyzed using the participation factor method. Moreover, a quantitative assessment of the impact of operational and control parameters closely associated with the strongly correlated state variables on the negative damper oscillation model is conducted. The findings of the analysis reveal that the small-disturbance stability of the WDCG is significantly influenced by the operational parameters of the outlet capacitance of the ma-chine-side converter (MSC), the outlet capacitance of the direct current wind turbine (DCWT), the sub-module capacitance of the modular multilevel converter (MMC), and the inductance of the bridge arm. Additionally, the stability is al-so affected by the control parameters of the constant DC voltage control on the DCWT side, the voltage outer-loop–current inner-loop control, and the circulation suppression on the MMC side. The simulation results based on PSCAD validate the efficacy of the proposed method in identifying the dominant factors.