Aleksandr Dmitrievich Usachev

Dr. Aleksandr Dmitrievich Usachev


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 October 2004 in Physical Review E
Verified
Journal Article
Closed access
PDF file
VFV. E. Fortov
V. E. Fortov
OPOleg Petrov
Oleg Petrov
AUAleksandr Dmitrievich Usachev
Aleksandr Dmitrievich Usachev
AZAndrey Vjacheslavovich Zobnin
Andrey Vjacheslavovich Zobnin
A method for measuring the interactions of charged dust particles within a three-dimensional dust cloud in a plasma is presented. The measurements have been performed with the help of gravity-driven heavy charged probe particles, which moved through a dust cloud levitating at the diffuse edge of an inductively coupled rf discharge plasma. Assuming a screened Coulomb potential surrounding each particle, both the particle charge and the effective screening length were calculated from an analysis of the elastic particle interactions for 20, 30, and 50 Pa of neon pressure. The basic parameters of the bulk discharge plasma have been diagnosed with a Langmuir probe to compare the experimental data with those deriving from different theoretical approaches. The observed discrepancies are discussed.

1 May 2014 in New Journal of Physics
Verified
Journal Article
Open access
PDF file
AUAleksandr Dmitrievich Usachev
Aleksandr Dmitrievich Usachev
AZA Zobnin
A Zobnin
OPO Petrov
O Petrov
VFV Fortov
V Fortov
MTM H Thoma
M H Thoma
GMG Morfill
G Morfill
The formation and dissipation of an externally excited planar dust acoustic shock wave in a three-dimensional uniform dust cloud has been observed under microgravity conditions. The experiment has been performed in the dc gas discharge chamber 'Plasma Kristall-4' (Fortov et al 2005 Plasma Phys. Control. Fusion 47 B537) on board the A300 Zero-G airplane. The shock Mach number and compression factor reached 3.5 and 6, correspondingly, with a shock width of about the interparticle distance. Due to the utilization of the polarity-switching dc discharge mode and application of the Rankine-Hugoniot relations, the dust particle electrostatic pressure was determined and the Hugoniot percussive adiabat for the dust subsystem was derived. The obtained data were simulated using thermodynamic properties of highly nonideal Debye-Hückel (Yukawa) systems. Comparison of the experimental and simulated data has demonstrated that the screening length in a dense dusty plasma is not determined by the total ion number density, but rather by those 'effective' ions which are not bounded by negatively charged dust grains. Thus, this work presents a new experimental approach for the investigation of the dense dusty plasma clouds.

26 January 2009 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
AUAleksandr Dmitrievich Usachev
Aleksandr Dmitrievich Usachev
AZA. V. Zobnin
A. V. Zobnin
OPO. F. Petrov
O. F. Petrov
VFV. E. Fortov
V. E. Fortov
BAB. M. Annaratone
B. M. Annaratone
GMG. E. Morfill
G. E. Morfill
An attraction between negatively charged micron-sized plastic particles was observed in the bulk of a low-pressure gas-discharge plasma under microgravity conditions. This attraction had led to the formation of a boundary-free dust cluster, containing one big central particle with a radius of about 6  μm and about 30 1  μm-sized particles situated on a sphere with a radius of 190  μm and with the big particle in the center. The stability of this boundary-free dust cluster was possible due to its confinement by the plasma flux on the central dust particle.

1 March 2018 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
AZAndrey Vjacheslavovich Zobnin
Andrey Vjacheslavovich Zobnin
AUAleksandr Dmitrievich Usachev
Aleksandr Dmitrievich Usachev
OPOleg Petrov
Oleg Petrov
VFV. E. Fortov
V. E. Fortov
MTM. H. Thoma
M. H. Thoma
MFM. A. Fink
M. A. Fink
The influence of a dust cloud on the structure of the positive column of a direct current gas discharge in a cylindrical glass tube under milligravity conditions has been studied both experimentally and numerically. The discharge was produced in neon at 60 Pa in a glass tube with a diameter of 30 mm at a discharge current 1 mA. Spherical monodisperse melamine formaldehyde dust particles with a diameter of 6.86 μm were injected into the positive column and formed there a uniform dust cloud with a maximum diameter of 14.4 mm. The shape of the cloud and the dust particle number density were measured. The cloud was stationary in the radial direction and slowly drifted in the axial direction. It was found that in the presence of the dust cloud, the intensity of the neon spectral line with a wavelength by 585.25 nm emitted by the discharge plasma increased by 2.3 times and 2 striations appeared on the anode side of the cloud. A numerical simulation of the discharge was performed using the 2D (quasi-3D) nonlocal self-consistent kinetic model of a longitudinally inhomogeneous axially symmetric positive column [Zobnin et al., Phys. Plasmas 21, 113503 (2014)], which was supplemented by a program module performing a self-consistent calculation of dust particle charges, the plasma recombination rate on dust particles, and ion scattering on dust particles. A new approach to the calculation of particle charges and the screening radius in dense dust clouds is proposed. The results of the simulation are presented, compared with experimental data and discussed. It is demonstrated that for the best agreement between simulated and experimental data, it is necessary to take into account the reflection of electrons from the dust particle surface in order to correctly describe the recombination rate in the cloud, its radial stability, and the dust particle charges.

6 April 2016 in Plasma Sources Science and Technology
Verified
Journal Article
Closed access
PDF file
AUAleksandr Dmitrievich Usachev
Aleksandr Dmitrievich Usachev
AZA V Zobnin
A V Zobnin
OPO F Petrov
O F Petrov
VFV E Fortov
V E Fortov
MTM H Thoma
M H Thoma
GMG E Morfill
G E Morfill
Experimental investigations of the formation of elongated dust clouds and their influence on the plasma glow intensity of the uniform direct current (DC) positive column (PC) have been performed under microgravity conditions. For the axial stabilization of the dust cloud position a polarity switching DC gas discharge with a switching frequency of 250 Hz was used. During the experiment, a spontaneous division of one elongated dust cloud into two smaller steady state dust clouds has been observed. Quantitative data on the dust cloud shape, size and dust number density distribution were obtained. Axial and radial distributions of plasma emission within the 585.2 nm and 703.2 nm neon spectral lines were measured over the whole discharge volume. It has been found that both spectral line intensities at the dust cloud region grew 1.7 times with respect to the undisturbed positive column region; in this the 585.2 nm line intensity increased by 10% compared to the 703.2 nm line intensity. For a semi-quantitative explanation of the observed phenomena the Schottky approach based on the equation of diffusion was used. The model reasonably explains the observed glow enhancement as an increasing of the ionization rate in the discharge with dust cloud, which compensates ion-electron recombination on the dust grain surfaces. In this, the ionization rate increases due to the growing of the DC axial electric field, and the glow grows directly proportional to the electric field. It is shown that the fundamental condition of the radial stability of the dusty plasma cloud is equal to the ionization and recombination rates within the cloud volume that is possible only when the electron density is constant and the radial electric field is absent within the dust cloud.

1 January 2018 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
AUAleksandr Dmitrievich Usachev
Aleksandr Dmitrievich Usachev
AZA V Zobnin
A V Zobnin
ASA V Shonenkov
A V Shonenkov
ALAndrey Mikhaylovich Lipaev
Andrey Mikhaylovich Lipaev
VMV I Molotkov
V I Molotkov
GPG I Padalka
G I Padalka
Influence of the elongated dust cloud on the intensities of different neon spectral lines in visible and near ir spectral ranges in the uniform positive column has been experimentally investigated using the Russian-European space apparatus "Plasma Kristall-4" (SA PK-4) on board of the International Space Station (ISS). The investigation was performed in the low pressure (0.5 mbar) direct current (dc, 1 mA) gas discharge in neon. Microgravity allowed us to perform experiments with a large dust cloud in the steady-state regime. To avoid the dust cloud drift in the dc electric field a switching dc polarity discharge mode has been applied. During the experiment a dust cloud of 9 mm in diameter in the discharge tube of 30 mm in diameter with the length of about 100 mm has been observed in the steady-state regime. In this regard, the intensities of neon spectral lines corresponding to 3p → 3s electronic transitions have increased by a factor of 1.4 times, while the intensities of neon spectral lines corresponding to 3d → 3p electronic transitions have increased by a factor of 1.6 times. The observed phenomenon is explained on the basis of the Schottky approach by a self-consistent rising dc electric field in the dusty plasma cloud resulting in an increase of the electron temperature.