Maria Cristina Valigi

Prof. Dr. Maria Cristina Valigi

Department of Engineering, University of Perugia, 06125 Perugia, Italy
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GAGabriele Maria Achilli
Gabriele Maria Achilli
Cinzia AmiciCinzia Amici
Cinzia Amici
MDMihai Dragusanu
Mihai Dragusanu
Massimiliano GobboMassimiliano Gobbo
Massimiliano Gobbo
Silvia LogozzoSilvia Logozzo
Silvia Logozzo
Maria Cristina ValigiMaria Cristina Valigi
Maria Cristina Valigi
In recent decades, extensive attention has been paid to the study and development of robotic devices specifically designed for hand rehabilitation. Accordingly, a many concepts concerning rigid, soft, and hybrid types have emerged in the literature, with significant ongoing activity being directed towards the development of new solutions. In this context, the paper focuses on the technical features of devices conceived for the robotic rehabilitation of the hand with reference to the three kinds of exoskeleton architecture and the clinical requirements demanded by the target impairment of the end-user. The work proposes a roadmap (i) for both the design and selection of exoskeletons for hand rehabilitation, (ii) to discriminate among the peculiarities of soft, rigid, and hybrid devices, and (iii) with an impairment-oriented rationale. The clinical requirements expected for an exoskeleton are identified by applying a PICO-inspired approach focused on the impairment analysis; the technical features are extracted from a proposed design process for exoskeletons combined with a narrative literature review. A cross-analysis between device families and features is presented to provide a supporting tool for both the design and selection of exoskeletons according to an impairment-oriented rationale.

6 December 2020 in Robotics
Verified
Journal Article
Open access
PDF file
GAGabriele Maria Achilli
Gabriele Maria Achilli
Maria Cristina ValigiMaria Cristina Valigi
Maria Cristina Valigi
GSGIONATA SALVIETTI
GIONATA SALVIETTI
Monica MalvezziMonica Malvezzi
Monica Malvezzi
Underactuated, modular and compliant hands and grippers are interesting solutions in grasping and manipulation tasks due to their robustness, versatility, and adaptability to uncertainties. However, this type of robotic hand does not usually have enough dexterity in grasping. The implementation of some specific features that can be represented as “embedded constraints” allows to reduce uncertainty and to exploit the role of the environment during the grasp. An example that has these characteristics is the Soft ScoopGripper a gripper that has a rigid flat surface in addition to a pair of modular fingers. In this paper, we propose an upgraded version of the Soft ScoopGripper, developed starting from the limits shown by the starting device. The new design exploits a modular structure to increase the adaptability to the shape of the objects that have to be grasped. In the proposed device the embedded constraint is no rigid neither unactuated and is composed of an alternation of rigid and soft modules, which increase versatility. Moreover, the use of soft material such as thermoplastic polyurethane (TPU) reduces the risk of damage to the object being grasped. In the paper, the main design choices have been exploited and a finite element method (FEM) analysis through static simulation supports a characterization of the proposed solution. A complete prototype and some preliminary tests have been presented.

18 May 2017 in Materials
Verified
Journal Article
Open access
PDF file
Maria Cristina ValigiMaria Cristina Valigi
Maria Cristina Valigi
Silvia LogozzoSilvia Logozzo
Silvia Logozzo
Saverio AffatatoSaverio Affatato
Saverio Affatato
Wear is a significant mechanical and clinical problem. To acquire further knowledge on the tribological phenomena that involve freeform mechanical components or medical prostheses, wear tests are performed on biomedical and industrial materials in order to solve or reduce failures or malfunctions due to material loss. Scientific and technological advances in the field of optical scanning allow the application of innovative devices for wear measurements, leading to improvements that were unimaginable until a few years ago. It is therefore important to develop techniques, based on new instrumentations, for more accurate and reproducible measurements of wear. The aim of this work is to discuss the use of innovative 3D optical scanners and an experimental procedure to detect and evaluate wear, comparing this technique with other wear evaluation methods for industrial components and biomedical devices.

11 December 2019 in Robotics
Verified
Journal Article
Open access
PDF file
Monica MalvezziMonica Malvezzi
Monica Malvezzi
ZIZubair Iqbal
Zubair Iqbal
Maria Cristina ValigiMaria Cristina Valigi
Maria Cristina Valigi
MPMaria Pozzi
Maria Pozzi
DPDomenico Prattichizzo
Domenico Prattichizzo
GSGIONATA SALVIETTI
GIONATA SALVIETTI
Augmenting the human hand with robotic extra fingers is a cutting-edge research topic and has many potential applications, in particular as a compensatory and rehabilitation tool for patients with upper limb impairments. Devices composed of two extra fingers are preferred with respect to single finger devices when reliable grasps, resistance to external disturbances, and higher payloads are required. Underactuation and compliance are design choices that can reduce the device complexity and weight, maintaining the adaptability to different grasped objects. When only one motor is adopted to actuate multiple fingers, a differential mechanism is necessary to decouple finger movements and distribute forces. In this paper, the main features of a wearable device composed of two robotic extra fingers are described and analyzed in terms of kinematics, statics, and mechanical resistance. Each finger is composed of modular phalanges and is actuated with a single tendon. Interphalangeal joints include a passive elastic element that allows restoring the initial reference configuration when the tendon is released. The stiffness of each passive element can be customized in the manufacturing process and can be chosen according to a desired closure movement of the fingers. Another key aspect of the device is the differential system connecting the actuator to the fingers.

1 April 2016 in Tribology International
Verified
Journal Article
Closed access
Maria Cristina ValigiMaria Cristina Valigi
Maria Cristina Valigi
Silvia LogozzoSilvia Logozzo
Silvia Logozzo
MRMIRKO RINCHI
MIRKO RINCHI

30 March 2017 in Materials
Verified
Journal Article
Open access
PDF file
Saverio AffatatoSaverio Affatato
Saverio Affatato
Maria Cristina ValigiMaria Cristina Valigi
Maria Cristina Valigi
Silvia LogozzoSilvia Logozzo
Silvia Logozzo
The objective of this study was to examine total knee polyethylene inserts from in vitro simulation to evaluate and display—using a 3D optical scanner—wear patterns and wear rates of inserts exposed to wear by means of simulators. Various sets of tibial inserts have been reconstructed by using optical scanners. With this in mind, the wear behavior of fixed and mobile bearing polyethylene knee configurations was investigated using a knee wear joint simulator. After the completion of the wear test, the polyethylene menisci were analyzed by an innovative 3D optical scanners in order to evaluate the 3D wear distribution on the prosthesis surface. This study implemented a new procedure for evaluating polyethylene bearings of joint prostheses obtained after in vitro wear tests and the proposed new approach allowed quantification of the contact zone on the geometry of total knee prostheses. The results of the present study showed that mobile TKPs (total knee prosthesis) have lower wear resistance with respect to fixed TKPs.