Silvia Logozzo

Dr. Silvia Logozzo

Department of Engineering,University of Perugia, 1, 06123 Perugia PG, Italy
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2017 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
FMFrancesco Mangano
Francesco Mangano
AGAndrea Gandolfi
Andrea Gandolfi
GLGiuseppe Luongo
Giuseppe Luongo
Silvia LogozzoSilvia Logozzo
Silvia Logozzo
Intraoral scanners (IOS) are devices for capturing direct optical impressions in dentistry. The purpose of this narrative review on the use of IOS was to: (1) identify the advantages/disadvantages of using optical impressions compared to conventional impressions; (2) investigate if optical impressions are as accurate as conventional impressions; (3) evaluate the differences between the IOS currently available commercially; (4) determine the current clinical applications/limitations in the use of IOS. Electronic database searches were performed using specific keywords and MeSH terms. The searches were confined to full-text articles written in English and published in peer-reviewed journals between January 2007 and June 2017. One hundred thirty-two studies were included in the present review; among them, 20 were previous literature reviews, 78 were in vivo clinical studies (6 randomized controlled/crossover trials, 31 controlled/comparative studies; 24 cohort studies/case series; 17 case reports) and 34 were in vitro comparative studies. Optical impressions reduce patient discomfort; IOS are time-efficient and simplify clinical procedures for the dentist, eliminating plaster models and allowing better communication with the dental technician and with patients; however, with IOS, it can be difficult to detect deep margin lines in prepared teeth and/or in case of bleeding, there is a learning curve, and there are purchasing and managing costs. The current IOS are sufficiently accurate for capturing impressions for fabricating a whole series of prosthetic restorations (inlays/onlays, copings and frameworks, single crowns and fixed partial dentures) on both natural teeth and implants; in addition, they can be used for smile design, and to fabricate posts and cores, removable partial prostheses and obturators. The literature to date does not support the use of IOS in long-span restorations with natural teeth or implants. Finally, IOS can be integrated in implant dentistry for guided surgery and in orthodontics for fabricating aligners and custom-made devices.

2 June 2017 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
MIMario Imburgia
Mario Imburgia
Silvia LogozzoSilvia Logozzo
Silvia Logozzo
UHUli Hauschild
Uli Hauschild
GVGiovanni Veronesi
Giovanni Veronesi
Carlo  ManganoCarlo Mangano
Carlo Mangano
FMFrancesco Mangano
Francesco Mangano
Until now, only a few studies have compared the ability of different intraoral scanners (IOS) to capture high-quality impressions in patients with dental implants. Hence, the aim of this study was to compare the trueness and precision of four IOS in a partially edentulous model (PEM) with three implants and in a fully edentulous model (FEM) with six implants. Two gypsum models were prepared with respectively three and six implant analogues, and polyether-ether-ketone cylinders screwed on. These models were scanned with a reference scanner (ScanRider®), and with four IOS (CS3600®, Trios3®, Omnicam®, TrueDefinition®); five scans were taken for each model, using each IOS. All IOS datasets were loaded into reverse-engineering software, where they were superimposed on the reference model, to evaluate trueness, and superimposed on each other within groups, to determine precision. A detailed statistical analysis was carried out. In the PEM, CS3600® had the best trueness (45.8 ± 1.6μm), followed by Trios3® (50.2 ± 2.5μm), Omnicam® (58.8 ± 1.6μm) and TrueDefinition® (61.4 ± 3.0μm). Significant differences were found between CS3600® and Trios3®, CS3600® and Omnicam®, CS3600® and TrueDefinition®, Trios3® and Omnicam®, Trios3® and TrueDefinition®. In the FEM, CS3600® had the best trueness (60.6 ± 11.7μm), followed by Omnicam® (66.4 ± 3.9μm), Trios3® (67.2 ± 6.9μm) and TrueDefinition® (106.4 ± 23.1μm). Significant differences were found between CS3600® and TrueDefinition®, Trios3® and TrueDefinition®, Omnicam® and TrueDefinition®. For all scanners, the trueness values obtained in the PEM were significantly better than those obtained in the FEM. In the PEM, TrueDefinition® had the best precision (19.5 ± 3.1μm), followed by Trios3® (24.5 ± 3.7μm), CS3600® (24.8 ± 4.6μm) and Omnicam® (26.3 ± 1.5μm); no statistically significant differences were found among different IOS. In the FEM, Trios3® had the best precision (31.5 ± 9.8μm), followed by Omnicam® (57.2 ± 9.1μm), CS3600® (65.5 ± 16.7μm) and TrueDefinition® (75.3 ± 43.8μm); no statistically significant differences were found among different IOS. For CS3600®, For CS3600®, Omnicam® and TrueDefinition®, the values obtained in the PEM were significantly better than those obtained in the FEM; no significant differences were found for Trios3®. Significant differences in trueness were found among different IOS; for each scanner, the trueness was higher in the PEM than in the FEM. Conversely, the IOS did not significantly differ in precision; for CS3600®, Omnicam® and TrueDefinition®, the precision was higher in the PEM than in the FEM. These findings may have important clinical implications.

1 March 2014 in Optics and Lasers in Engineering
Verified
Journal Article
Closed access
Silvia LogozzoSilvia Logozzo
Silvia Logozzo
Elisabetta ZanettiElisabetta Zanetti
Elisabetta Zanetti
GFGiordano Franceschini
Giordano Franceschini
AKAri Kilpelä
Ari Kilpelä
AMAnssi Mäkynen
Anssi Mäkynen

14 October 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GAGabriele Maria Achilli
Gabriele Maria Achilli
Cinzia AmiciCinzia Amici
Cinzia Amici
MDMihai Dragusanu
Mihai Dragusanu
Massimiliano GobboMassimiliano Gobbo
Massimiliano Gobbo
Silvia LogozzoSilvia Logozzo
Silvia Logozzo
Maria Cristina ValigiMaria Cristina Valigi
Maria Cristina Valigi
In recent decades, extensive attention has been paid to the study and development of robotic devices specifically designed for hand rehabilitation. Accordingly, a many concepts concerning rigid, soft, and hybrid types have emerged in the literature, with significant ongoing activity being directed towards the development of new solutions. In this context, the paper focuses on the technical features of devices conceived for the robotic rehabilitation of the hand with reference to the three kinds of exoskeleton architecture and the clinical requirements demanded by the target impairment of the end-user. The work proposes a roadmap (i) for both the design and selection of exoskeletons for hand rehabilitation, (ii) to discriminate among the peculiarities of soft, rigid, and hybrid devices, and (iii) with an impairment-oriented rationale. The clinical requirements expected for an exoskeleton are identified by applying a PICO-inspired approach focused on the impairment analysis; the technical features are extracted from a proposed design process for exoskeletons combined with a narrative literature review. A cross-analysis between device families and features is presented to provide a supporting tool for both the design and selection of exoskeletons according to an impairment-oriented rationale.

18 May 2017 in Materials
Verified
Journal Article
Open access
PDF file
Maria Cristina ValigiMaria Cristina Valigi
Maria Cristina Valigi
Silvia LogozzoSilvia Logozzo
Silvia Logozzo
Saverio AffatatoSaverio Affatato
Saverio Affatato
Wear is a significant mechanical and clinical problem. To acquire further knowledge on the tribological phenomena that involve freeform mechanical components or medical prostheses, wear tests are performed on biomedical and industrial materials in order to solve or reduce failures or malfunctions due to material loss. Scientific and technological advances in the field of optical scanning allow the application of innovative devices for wear measurements, leading to improvements that were unimaginable until a few years ago. It is therefore important to develop techniques, based on new instrumentations, for more accurate and reproducible measurements of wear. The aim of this work is to discuss the use of innovative 3D optical scanners and an experimental procedure to detect and evaluate wear, comparing this technique with other wear evaluation methods for industrial components and biomedical devices.

1 March 2014 in Optics and Lasers in Engineering
Verified
Journal Article
Closed access
Silvia LogozzoSilvia Logozzo
Silvia Logozzo
AKAri Kilpelä
Ari Kilpelä
AMAnssi Mäkynen
Anssi Mäkynen
Elisabetta ZanettiElisabetta Zanetti
Elisabetta Zanetti
GFGiordano Franceschini
Giordano Franceschini