Ivar Kiitam

Ivar Kiitam


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2022 in Energies
Verified
Journal Article
Open access
PDF file
MCManinder Choudhary
Maninder Choudhary
Muhammad ShafiqMuhammad Shafiq
Muhammad Shafiq
IKIvar Kiitam
Ivar Kiitam
Ghulam Amjad HussainGhulam Amjad Hussain
Ghulam Amjad Hussain
IPIvo Palu
Ivo Palu
PTPaul Taklaja
Paul Taklaja
Electrical insulation is an integral part of power components. The aging of electrical insulation is an undeniable fact that limits the operational lifetime of power components. Apart from regular aging, abnormal stresses and the development of defects are real threats because of their contribution in accelerating the aging rate and thereby leading to a premature failure of the power components. Over the decades, various studies have been carried out to understand the aging behavior of electrical insulation mainly considering electrical and thermal stresses. Similarly, a number of mathematical (aging) models have been developed based on the theoretical and experimental investigations and evidences. However, a dependable formulation of the models that can provide more practical estimation of the insulation degradation profile has not been achieved yet. This paper presents a comprehensive review of the aging models considering single and multistress conditions. Further, the paper discusses possible challenges and barricades averting the conventional models to achieve a suitable accuracy. Finally, suggestions are provided that can be considered to improve the modeling approaches and their performance.
1

23 January 2024 in Engineering Failure Analysis
Verified
Journal Article
Closed access
MCManinder Choudhary
Maninder Choudhary
Muhammad ShafiqMuhammad Shafiq
Muhammad Shafiq
IKIvar Kiitam
Ivar Kiitam
IPIvo Palu
Ivo Palu
WHWaqar Hassan
Waqar Hassan
PSPraveen Prakash Singh
Praveen Prakash Singh

16 November 2023 in Electric Power Systems Research
Verified
Journal Article
Open access
SMSambeet Mishra
Sambeet Mishra
PSPraveen Prakash Singh
Praveen Prakash Singh
IKIvar Kiitam
Ivar Kiitam
Muhammad ShafiqMuhammad Shafiq
Muhammad Shafiq
IPIvo Palu
Ivo Palu
Chiara BordinChiara Bordin
Chiara Bordin

18 August 2020 in Energies
Verified
Journal Article
Open access
PDF file
Muhammad ShafiqMuhammad Shafiq
Muhammad Shafiq
IKIvar Kiitam
Ivar Kiitam
Kimmo KauhaniemiKimmo Kauhaniemi
Kimmo Kauhaniemi
PTPaul Taklaja
Paul Taklaja
LKLauri Kütt
Lauri Kütt
IPIvo Palu
Ivo Palu
Already installed cables are aging and the cable network is growing rapidly. Improved condition monitoring methods are required for greater visibility of insulation defects in the cable networks. One of the critical challenges for continuous monitoring is the large amount of partial discharge (PD) data that poses constraints on the diagnostic capabilities. This paper presents the performance comparison of two data acquisition techniques based on phase resolved partial discharge (PRPD) and pulse acquisition (PA). The major contribution of this work is to provide an in-depth understanding of these techniques considering the perspective of randomness of the PD mechanism and improvements in the reliability of diagnostics. Experimental study is performed on the medium voltage (MV) cables in the laboratory environment. It has been observed that PRPD based acquisition not only requires a significantly larger amount of data but is also susceptible to losing the important information especially when multiple PD sources are being investigated. On the other hand, the PA technique presents improved performance for PD diagnosis. Furthermore, the use of the PA technique enables the efficient practical implementation of the continuous PD monitoring by reducing the amount of data that is acquired by extracting useful signals and discarding the silent data intervals.

3 April 2025 in Electric Power Systems Research
Verified
Journal Article
Closed access
MCManinder Choudhary
Maninder Choudhary
MSMuhammad Shafiq
Muhammad Shafiq
Abhinav BhattaraiAbhinav Bhattarai
Abhinav Bhattarai
IKIvar Kiitam
Ivar Kiitam
PTPaul Taklaja
Paul Taklaja
IPIvo Palu
Ivo Palu

23 August 2021
Verified
Conference Paper
Closed access
IKIvar Kiitam
Ivar Kiitam
Muhammad ShafiqMuhammad Shafiq
Muhammad Shafiq
PTPaul Taklaja
Paul Taklaja
MPMartin Parker
Martin Parker
IPIvo Palu
Ivo Palu
LKLauri Kütt
Lauri Kütt
The measurement of partial discharges (PD) is an important approach used in identifying the presence of defects in high voltage insulation. This paper investigates various parameters characteristic to different types of PD, which can be used for the purposes of achieving more effective PD source discrimination. Measurements were performed on three distinct PD sources using a high-frequency current transformer to detect pulses. Parameters to characterize the PD activity were calculated, including statistical, pulse width, pulse interval and sequential pulse voltage differences. The degree of positive and negative half-cycle asymmetry was also determined. The results obtained indicate that the most significant differences in the parameter values, which can be used to distinguish between different source types, are associated with pulse count, pulse peak values, PD occurrence phase, pulse widths, sequential pulse intervals, voltage differences and correlation between pulse waveforms.