24 May 2023 in IEEE Access
In modern power systems, condition based monitoring and diagnosis is essential to ensure the effective and reliable operation of different high voltage equipment (HVE). Compared to other monitoring techniques, partial discharges (PD) measurement is considered as a key method for assessing the insulation health condition. The benefits of PD condition monitoring of HVE can be extended by proper detection, identification, and interpretation of PD signal. Among both on-line and off-line PD monitoring techniques, on-line PD monitoring is a very promising technique that assists in robust monitoring system which reduces the power failure incidents in power system components. Therefore, to understand recent developments and trends in theory and in practice, it is necessary to establish a holistic analysis of current on-line PD monitoring techniques for HVE in power systems. This paper presents an intensive literature review of current on-line PD monitoring techniques used for different high voltage electric components in power system. Finally, a smart PD monitoring techniques based on wireless sensor board is proposed. The proposed smart PD monitoring framework may be used to correctly estimate the insulation degradation in HVE and enhance the overall performance of power systems.
28 May 2020 in IEEE Access
Partial discharges (PD) are produced in the stator insulation of electrical machines while energized. The sources of PD are internal voids, crack, and manufacturing defects, which keep on extending with its normal operation, leading to the complete failure of insulation. The intensity of PD is considerably influenced by the environmental factors, including surrounding temperature, pressure, humidity, and contamination. This paper investigates the influence of these factors on the PD activity in electrical machines and estimates the lifetime of insulation. The PD measurements were conducted by placing the motors in a climate-controlled chamber. The PD trend under varying environmental stresses was investigated over time. Accordingly, PD inception voltage and various discharge characteristic parameters such as accumulated apparent charge, cumulative energy function, average discharge current, discharge power, and quadratic rate have been determined. The combined effect of various environmental stresses on the PD activity was also investigated. The mathematical relationships were developed to estimate the discharge characteristics as the functions of pressure and temperature using the Gaussian model and the Exponential model. Finally, the endurance of insulation was estimated under different environmental conditions based on the average discharge current to differentiate between correct and incorrect PD measurements and to develop a right maintenance schedule for motors in service.
4 May 2023 in Electric Power Systems Research
23 January 2024 in Engineering Failure Analysis
28 March 2023 in IEEE Transactions on Aerospace and Electronic Systems
Typically, partial discharges (PD) diagnostic tests are carried out in laboratories under standard atmospheric conditions. However, during operation of electric motors (EM), environmental stresses may increase due to variations in the atmospheric pressure and temperature. This is, for example, the case of electrical aircrafts and, in general, aerospace. Experimental results show that these stresses may affect the level and phenomenology of PD, so as to harm insulation system reliability. Therefore, neglecting the actual environmental stresses involved in PD testing or monitoring may result in incorrect interpretation health condition of EM. This study presents a framework to properly assess the impact of environmental stresses on PD activity and estimate the failure risk of EM insulation. For this purpose, PD diagnostics were carried out by performing a number of experiments on seven EM in a climate-controlled chamber. PD characteristic features at different levels of environmental stresses are extracted from measurements in order to investigate the PD severity and infer their effect on the resulting insulation degradation. Also, various probability distribution functions are used to estimate the probability of failure and risk assessment corresponding to the PD severity at different levels of environmental stresses. The proposed risk assessment technique can be helpful to plan regular maintenance activities and repair-replacement actions, keeping the reliability at the level requested for most of the industrial applications involved with variable temperature and pressure operations.
15 December 2021 in IEEE Transactions on Industrial Electronics
Typically, in partial discharges (PD) diagnostics tests carried out in a laboratory, harmonic content in a voltage waveform is ignored. However, during the operation of variable-frequency drives (VFD)-fed electric motors, the distorted voltage waveform is produced due to the addition of harmonics components in the sinusoidal voltage waveform. The distortion level increases when the VFD is operated at a lower speed ratio. The additional spectral components in the applied voltage waveform can have a significant impact on the PD behavior in the insulation of the electric motor. Therefore, during online PD monitoring, overlooking the harmonic regime in the applied voltage may lead to a false interpretation of PD data. This article investigates the influence of voltage harmonics distortion produced during the variable-speed operation of VFD on PD characteristics. For this purpose, online PD measurements have been carried out by performing a series of experiments on eight VFD-fed motors under variable operating conditions. The PD severity at different harmonic compositions is experimentally investigated by determining various PD characteristic parameters including PD inception voltage, accumulated apparent charge, average discharge current, discharge power, and quadratic rate. Also, two terms Gaussian models have been mathematically developed using 288 data samples to quantify the variations in PD characteristic parameters against distortion parameters. The article proposes a framework for properly evaluating harmonics impact in PD for electric motors and correctly estimating stator insulation degradation.