Toshiaki Inada

Dr. Toshiaki Inada


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2018 in Journal of Cosmology and Astroparticle Physics
Verified
Journal Article
Open access
PDF file
SKStefan Knirck
Stefan Knirck
TYTakayuki Yamazaki
Takayuki Yamazaki
YOYoshiki Okesaku
Yoshiki Okesaku
SAShoji Asai
Shoji Asai
TIToshitaka Idehara
Toshitaka Idehara
TIToshiaki Inada
Toshiaki Inada
We report on the first results from a new dish antenna search for hidden photon dark matter (HPDM) in the meV mass region. A double mirror system composed of a plane and a parabolic mirror is designed to convert HPDMs into photons focused on a receiver. In this phase 1 experiment we obtain an upper limit on the photon-HP kinetic mixing χ 10-8 for the mass range of 0.67-0.92 meV using conventional mm-wave technology with a roomtemperature receiver and a small-sized mirror system.

22 November 2023 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
SCShion Chen
Shion Chen
HFHajime Fukuda
Hajime Fukuda
TIToshiaki Inada
Toshiaki Inada
TMTakeo Moroi
Takeo Moroi
TNTatsumi Nitta
Tatsumi Nitta
TSThanaporn Sichanugrist
Thanaporn Sichanugrist
We propose a novel dark matter detection method utilizing the excitation of superconducting transmon qubits. Assuming the hidden photon dark matter of a mass of O(10)  μeV, the classical wave-matter oscillation induces an effective ac electric field via the small kinetic mixing with the ordinary photon. This serves as a coherent drive field for a qubit when it is resonant, evolving it from the ground state towards the first-excited state. We evaluate the rate of such evolution and observable excitations in the measurements, as well as the search sensitivity to the hidden photon dark matter. For a selected mass, one can reach ε∼10−13–10−12 (where ε is the kinetic mixing parameter of the hidden photon) with a few tens of seconds using a single standard transmon qubit. A simple extension to the frequency-tunable SQUID-based transmon enables the mass scan to cover the range of 4–40  μeV (1–10 GHz) within a reasonable length of run time. The scheme has great potential to extend the sensitivity towards various directions including being incorporated into the cavity-based haloscope experiments or the currently available multibit noisy intermediate-scale quantum (NISQ) computer machines.

29 June 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TIToshiaki Inada
Toshiaki Inada
TYTakayuki Yamazaki
Takayuki Yamazaki
TYTomohiro Yamaji
Tomohiro Yamaji
YSYudai Seino
Yudai Seino
XFXing Fan
Xing Fan
SAShoji Asai
Shoji Asai
A nonlinear interaction between photons is observed in a process that involves charge sources. To observe this process in a vacuum, there are a growing number of theoretical and experimental studies. This process may contain exotic contribution from new physics beyond the Standard Model of particle physics, and is probed by experiments using a high-power laser or a high-field magnet, and more recently using an X-ray free-electron laser (XFEL). Here, we review the present status of our experiments testing various vacuum processes. We describe four experiments with a focus on those using an XFEL: (i) photon–photon scattering in the X-ray region, (ii) laser-induced birefringence and diffraction of X rays, (iii) vacuum birefringence induced by a high-field magnet, and (iv) a dedicated search for axion-like particles using the magnet and X rays.

1 May 2014 in Physics Letters B
Verified
Journal Article
Open access
TIToshiaki Inada
Toshiaki Inada
TYT. Yamaji
T. Yamaji
SAS. Adachi
S. Adachi
TNT. Namba
T. Namba
SAS. Asai
S. Asai
TIT. Ishikawa
T. Ishikawa
We report the first results of a search for real photon–photon scattering using X rays. A novel system is developed to split and collide X-ray pulses by applying interferometric techniques. A total of 6.5×105 pulses (each containing about 1011 photons) from an X-ray Free-Electron Laser are injected into the system. No scattered events are observed, and an upper limit of 1.7×10−24 m2 (95% C.L.) is obtained on the photon–photon elastic scattering cross section at 6.5 keV

18 April 2014 in arXiv
Verified
Preprint
Open access
PDF file
TIToshiaki Inada
Toshiaki Inada
TYT. Yamaji
T. Yamaji
SAS. Adachi
S. Adachi
TNT. Namba
T. Namba
SAS. Asai
S. Asai
TIT. Ishikawa
T. Ishikawa
We report the first results of a search for real photon-photon scattering using X rays. A novel system is developed to split and collide X-ray pulses by applying interferometric techniques. A total of $6.5\times10^{5}$ pulses (each containing about $10^{11}$ photons) from an X-ray Free-Electron Laser are injected into the system. No scattered events are observed, and an upper limit of $1.7\times 10^{-24}$ ${\rm m^{2}}$ (95% C.L.) is obtained on the photon-photon elastic scattering cross section at 6.5 keV.

31 August 2026 in Applied Physics Letters
Verified
Journal Article
Closed access
RORyutaro Ohira
Ryutaro Ohira
SMShinichi Morisaka
Shinichi Morisaka
YKYoshinori Kurimoto
Yoshinori Kurimoto
TIToshiaki Inada
Toshiaki Inada
INIppei Nakamura
Ippei Nakamura
ANAtsushi Noguchi
Atsushi Noguchi
Trapped-ion quantum computers based on the quantum charge-coupled device architecture require on the order of ten trap electrodes per qubit, making the number of vacuum feedthroughs a bottleneck at the system scale. Time-division multiplexed (TDM)-based voltage control for trap electrodes provides a natural route to alleviate this constraint. However, previous studies have been limited to architectural proposals for static trap-potential compensation and room-temperature demonstrations of dynamic-electrode control, leaving cryogenic operation of TDM-based voltage control for static and dynamic electrodes experimentally unexplored. In this study, we develop and cryogenically validate TDM-based voltage control schemes for two distinct electrode classes. For static electrodes used in trap-potential compensation, we implement a 32-channel demultiplexed system operating at approximately 27 K, achieving an effective voltage update rate of 37.5 kHz with an output range of ±10 V per channel. For dynamic electrodes used in ion operations, such as shuttling, we implement a four-channel demultiplexed system operating at approximately 14 K, achieving an effective voltage update rate of 1 MHz with a comparable output range. These results establish TDM-based voltage control as a practical approach for both electrode classes, providing a path for mitigating the vacuum feedthrough bottleneck in scalable trapped-ion quantum processors.