We report on the first results from a new dish antenna search for hidden photon dark matter (HPDM) in the meV mass region. A double mirror system composed of a plane and a parabolic mirror is designed to convert HPDMs into photons focused on a receiver. In this phase 1 experiment we obtain an upper limit on the photon-HP kinetic mixing χ 10-8 for the mass range of 0.67-0.92 meV using conventional mm-wave technology with a roomtemperature receiver and a small-sized mirror system.
We propose a novel dark matter detection method utilizing the excitation of superconducting transmon qubits. Assuming the hidden photon dark matter of a mass of , the classical wave-matter oscillation induces an effective ac electric field via the small kinetic mixing with the ordinary photon. This serves as a coherent drive field for a qubit when it is resonant, evolving it from the ground state towards the first-excited state. We evaluate the rate of such evolution and observable excitations in the measurements, as well as the search sensitivity to the hidden photon dark matter. For a selected mass, one can reach (where is the kinetic mixing parameter of the hidden photon) with a few tens of seconds using a single standard transmon qubit. A simple extension to the frequency-tunable SQUID-based transmon enables the mass scan to cover the range of (1–10 GHz) within a reasonable length of run time. The scheme has great potential to extend the sensitivity towards various directions including being incorporated into the cavity-based haloscope experiments or the currently available multibit noisy intermediate-scale quantum (NISQ) computer machines.
A nonlinear interaction between photons is observed in a process that involves charge sources. To observe this process in a vacuum, there are a growing number of theoretical and experimental studies. This process may contain exotic contribution from new physics beyond the Standard Model of particle physics, and is probed by experiments using a high-power laser or a high-field magnet, and more recently using an X-ray free-electron laser (XFEL). Here, we review the present status of our experiments testing various vacuum processes. We describe four experiments with a focus on those using an XFEL: (i) photon–photon scattering in the X-ray region, (ii) laser-induced birefringence and diffraction of X rays, (iii) vacuum birefringence induced by a high-field magnet, and (iv) a dedicated search for axion-like particles using the magnet and X rays.
We report the first results of a search for real photon–photon scattering using X rays. A novel system is developed to split and collide X-ray pulses by applying interferometric techniques. A total of 6.5×105 pulses (each containing about 1011 photons) from an X-ray Free-Electron Laser are injected into the system. No scattered events are observed, and an upper limit of 1.7×10−24 m2 (95% C.L.) is obtained on the photon–photon elastic scattering cross section at 6.5 keV
We report the first results of a search for real photon-photon scattering using X rays. A novel system is developed to split and collide X-ray pulses by applying interferometric techniques. A total of $6.5\times10^{5}$ pulses (each containing about $10^{11}$ photons) from an X-ray Free-Electron Laser are injected into the system. No scattered events are observed, and an upper limit of $1.7\times 10^{-24}$ ${\rm m^{2}}$ (95% C.L.) is obtained on the photon-photon elastic scattering cross section at 6.5 keV.
Trapped-ion quantum computers based on the quantum charge-coupled device architecture require on the order of ten trap electrodes per qubit, making the number of vacuum feedthroughs a bottleneck at the system scale. Time-division multiplexed (TDM)-based voltage control for trap electrodes provides a natural route to alleviate this constraint. However, previous studies have been limited to architectural proposals for static trap-potential compensation and room-temperature demonstrations of dynamic-electrode control, leaving cryogenic operation of TDM-based voltage control for static and dynamic electrodes experimentally unexplored. In this study, we develop and cryogenically validate TDM-based voltage control schemes for two distinct electrode classes. For static electrodes used in trap-potential compensation, we implement a 32-channel demultiplexed system operating at approximately 27 K, achieving an effective voltage update rate of 37.5 kHz with an output range of ±10 V per channel. For dynamic electrodes used in ion operations, such as shuttling, we implement a four-channel demultiplexed system operating at approximately 14 K, achieving an effective voltage update rate of 1 MHz with a comparable output range. These results establish TDM-based voltage control as a practical approach for both electrode classes, providing a path for mitigating the vacuum feedthrough bottleneck in scalable trapped-ion quantum processors.