Jay Gupta

Mr. Jay Gupta

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
LBLaura J. Brattain
Laura J. Brattain
TPTheodore Thomas Pierce
Theodore Thomas Pierce
LGLars Gjesteby
Lars Gjesteby
MJMatthew R. Johnson
Matthew R. Johnson
NDNancy D. DeLosa
Nancy D. DeLosa
ASAnthony E. Samir
Anthony E. Samir
Hemorrhage is a leading cause of trauma death, particularly in prehospital environments when evacuation is delayed. Obtaining central vascular access to a deep artery or vein is important for administration of emergency drugs and analgesics, and rapid replacement of blood volume, as well as invasive sensing and emerging life-saving interventions. However, central access is normally performed by highly experienced critical care physicians in a hospital setting. We developed a handheld AI-enabled interventional device, AI-GUIDE (Artificial Intelligence Guided Ultrasound Interventional Device), capable of directing users with no ultrasound or interventional expertise to catheterize a deep blood vessel, with an initial focus on the femoral vein. AI-GUIDE integrates with widely available commercial portable ultrasound systems and guides a user in ultrasound probe localization, venous puncture-point localization, and needle insertion. The system performs vascular puncture robotically and incorporates a preloaded guidewire to facilitate the Seldinger technique of catheter insertion. Results from tissue-mimicking phantom and porcine studies under normotensive and hypotensive conditions provide evidence of the technique’s robustness, with key performance metrics in a live porcine model including: a mean time to acquire femoral vein insertion point of 53 ± 36 s (5 users with varying experience, in 20 trials), a total time to insert catheter of 80 ± 30 s (1 user, in 6 trials), and a mean number of 1.1 (normotensive, 39 trials) and 1.3 (hypotensive, 55 trials) needle insertion attempts (1 user). These performance metrics in a porcine model are consistent with those for experienced medical providers performing central vascular access on humans in a hospital.

12 June 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
AKAlexandre Kisner
Alexandre Kisner
JSJulia E Slocomb
Julia E Slocomb
SSSarah Sarsfield
Sarah Sarsfield
MZMaria Laura Zuccoli
Maria Laura Zuccoli
JSJustin Siemian
Justin Siemian
YAYeka Aponte
Yeka Aponte
Cracking the cytoarchitectural organization, activity patterns, and neurotransmitter nature of genetically-distinct cell types in the lateral hypothalamus (LH) is fundamental to develop a mechanistic understanding of how activity dynamics within this brain region are generated and operate together through synaptic connections to regulate circuit function. However, the precise mechanisms through which LH circuits orchestrate such dynamics have remained elusive due to the heterogeneity of the intermingled and functionally distinct cell types in this brain region. Here we reveal that a cell type in the mouse LH identified by the expression of the calcium-binding protein parvalbumin (PVALB; LHPV) is fast-spiking, releases the excitatory neurotransmitter glutamate, and sends long range projections throughout the brain. Thus, our findings challenge long-standing concepts that define neurons with a fast-spiking phenotype as exclusively GABAergic. Furthermore, we provide for the first time a detailed characterization of the electrophysiological properties of these neurons. Our work identifies LHPV neurons as a novel functional component within the LH glutamatergic circuitry.

14 December 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
JGJay Gupta
Jay Gupta
SASaaid Haseeb Arshad
Saaid Haseeb Arshad
Brian TelferBrian Telfer
Brian Telfer
ESEric Joseph Snider
Eric Joseph Snider
Victor A. ConvertinoVictor A. Convertino
Victor A. Convertino
Hemorrhage is the leading cause of preventable death from trauma. Accurate monitoring of hemorrhage and resuscitation can significantly reduce mortality and morbidity but remains a challenge due to the low sensitivity of traditional vital signs in detecting blood loss and possible hemorrhagic shock. Vital signs are not reliable early indicators because of physiological mechanisms that compensate for blood loss and thus do not provide an accurate assessment of volume status. As an alternative, machine learning (ML) algorithms that operate on an arterial blood pressure (ABP) waveform have been shown to provide an effective early indicator. However, these ML approaches lack physiological interpretability. In this paper, we evaluate and compare the performance of ML models trained on nine ABP-derived features that provide physiological insight, using a database of 13 human subjects from a lower-body negative pressure (LBNP) model of progressive central hypovolemia and subsequent progressive restoration to normovolemia (i.e., simulated hemorrhage and whole blood resuscitation). Data were acquired at multiple repressurization rates for each subject to simulate varying resuscitation rates, resulting in 52 total LBNP collections. This work is the first to use a single ABP-based algorithm to monitor both simulated hemorrhage and resuscitation. A gradient-boosted regression tree model trained on only the half-rise to dicrotic notch (HRDN) feature achieved a root-mean-square error (RMSE) of 13%, an R2 of 0.82, and area under the receiver operating characteristic curve of 0.97 for detecting decompensation. This single-feature model’s performance compares favorably to previously reported results from more-complex black box machine learning models. This model further provides physiological insight because HRDN represents an approximate measure of the delay between the ABP ejected and reflected wave and therefore is an indication of cardiac and peripheral vascular mechanisms that contribute to the compensatory response to blood loss and replacement.

24 March 2026 in IEEE Transactions on Ultrasonics
Verified
Journal Article
Closed access
JGJay Gupta
Jay Gupta
ICIon Candel
Ion Candel
SSScott Schoen
Scott Schoen
MOMark Ottensmeyer
Mark Ottensmeyer
SASaaid H. Arshad
Saaid H. Arshad
ASAnthony E. Samir
Anthony E. Samir
Hemorrhage is the leading cause of preventable death from trauma, with most fatalities occurring in pre-hospital settings. The current standard for point-of-care hemorrhage detection is the focused assessment with sonography in trauma (FAST) exam, or computed tomography (CT) angiography after hospital arrival. Contrast-enhanced ultrasound (CEUS) has been proposed as a next-generation FAST exam, due to potential for (1) differentiating active vs. inactive bleeding, (2) localizing bleeding sources, and (3) guiding percutaneous and/or endovascular treatments to temporize bleeding for prolonged transport. While these advantages have been reported in human trauma case studies, characterization of the minimum hemorrhage rate detectable by CEUS remains a translational research need. Prior work using conventional B-mode imaging and microvascular CEUS algorithms showed detection of 5 mL/min flow in a generic hemorrhage phantom. Here, we apply nonlinear imaging waveforms (pulse inversion, PI, and amplitude modulation, AM) with an iterative spatiotemporal filter that further enhances contrast signals (fast iterative-shrinkage thresholding algorithm, FISTA) to detect significantly lower flow rates in an anatomically realistic abdominal hemorrhage phantom. We demonstrate detection of bleeding at a minimum flow rate of 0.5 mL/min, comparable to multidetector CT. We achieve this detection limit even with 10% of the standard contrast dose (area under the receiver operating characteristic curve of 0.90 and 0.84 for PI+FISTA and AM+FISTA, respectively, compared to 0.38 for conventional B-mode), suggesting that CEUS examination is feasible throughout contrast wash-in / wash-out. Finally, to bridge towards in vivo characterization, we present a novel porcine liver hemorrhage model tailored to evaluating CEUS capabilities.