The conventional model predictive torque control (MPTC) suffers from the heavy computation burden and the uncertainty of the weighting factor. This article proposed a new MPTC scheme for a five-phase permanent magnet synchronous motor by using double virtual voltage vectors (VVVs), in which no weighting factor is required. The VVVs that can restrain the harmonics work as the candidate vectors. The deadbeat principle is adopted to predict the reference voltage, which can be used to select the optimal VVV directly in avoid of testing all candidate VVVs, and hence, the computation burden is reduced. The geometric principle is applied to select the second voltage vector and calculate the vector duration. The second vector can be a VVV or null vector. Therefore, double VVVs or a VVV and a null vector can be synthesized for the next period. It should be noted that no weighting factor is required because of the introduced geometric principle. Due to the selection of the second voltage vector, the torque and flux ripples are reduced and the steady-state performance is improved. The proposed MPTC has the same fast dynamic response with the conventional MPTC. The experiments are presented to verify the proposed MPTC scheme.
3 December 2021 in IEEE Transactions on Energy Conversion
The conventional model predictive power control suffers from heavy computational burden and large power ripple. To address the problem, this paper proposes a simplified three-vector-based model predictive direct power control, which can greatly optimize the control set. Firstly, a switching table is designed to exclude the redundant virtual voltage vectors (VVs). Only half of the candidate VVs are retained. Then, the effect of each VV on power is analyzed in detail. The deviation of reactive power is used as the evidence to further simplify the control set. In this way, the prediction behavior is reduced from 12 to 2, which effectively reduces the computational burden. In addition, the concept of power deadbeat is employed to determine the duty cycles of the two virtual VVs and one zero VV. Thus, the power ripples and current harmonics can be considerably suppressed. With this proposed method, the calculation complexity is reduced, and the steady-state performance is improved. The simulation and experimental results are given to verify the proposed method.
1 December 2018 in Chinese Journal of Electrical Engineering
This paper presents a comparative performance analysis of a new five-phase fault-tolerant flux-switching permanent-magnet(FT-FSPM) motor for high-reliability applications under the two most popular control schemes, namely, field-oriented control(FOC) and direct torque control(DTC) based on stator-flux orientation. Firstly, the new motor topology and structural characteristics are briefly presented. Secondly, the d- and q-axis for the FT-FSPM motor are defined, which is crucial to the mathematical model and control scheme, and the mathematical models are derived. Then, two control schemes, i.e., FOC and DTC, and the main system are proposed. The operational principles of the two control schemes are presented, and space vector pulse width modulation(SVPWM) based on four neighboring vectors is adopted to reduce current harmonics and torque ripples. Finally, the simulated and experimental results are given, and performance analysis of the two control schemes are compared and discussed. The results reveal that FOC scheme has the sinusoidal phase current and low torque ripples, while the DTC scheme has fast dynamic response, verifying the effectiveness of the two proposed control schemes. This paper is a primary investigation for more possible improvements in the control schemes of the five-phase FS-FTPM motor.
13 April 2022 in IEEE Transactions on Power Electronics
This article proposed a self-adapted model predictive current control (SA-MPCC) method to reduce the switching loss of the five-phase open-end winding permanent-magnet synchronous motor (OW-PMSM). The proposed SA-MPCC method regards the OW-PMSM drive system as two separate parts by utilizing the flexibility of the OW-PMSM system, thus generating and applying the phase voltage to armature winding independently. The virtual voltage vectors and multivector duty cycle modulation strategy is adopted to maintain a good steady-state and dynamic behavior. Then, the self-adapted decision is generated to choose one inverter work solely, or two inverters work cooperatively. When one inverter is used, another inverter is closed. The first inverter is clamped to optimal virtual voltage vectors when two inverters work together. The clamping to virtual voltage vectors or zero vectors can reduce the switching loss in both sides of the dual inverter. Finally, the experimental results verify the effectiveness of the proposed SA-MPCC method.
16 December 2020 in IEEE Transactions on Vehicular Technology
Because of the enhanced utilization of dc-link voltage and the low cost of power supply, common dc-link dual-inverter is a desirable drive topology to solve the low power factor problem of open-winding linear permanent-magnet vernier motor (OW-LPMVM). However, the common dc-link structure causes a zero-sequence current (ZSC) in the motor windings, which increases current distortion and thrust ripple of the LPMVM. To effectively decrease the ZSC as well as thrust ripple, this paper proposes a three-vector-based model predictive current control (TV-MPCC) scheme. In the proposed TV-MPCC, one optimal vector produced by one of the dual-inverter is obtained based on the deadbeat current control principle, which simplifies the prediction process and reduce the switching frequency. On the other hand, the other two optimal vectors produced by another of the dual-inverter are obtained by means of a cost function cascade evaluation, which improves the steady-state performance. With the proposed scheme, the ZSC is effectively suppressed with the simple implementation, enhanced thrust performance, fast transient response, good robustness against parameter variations, and reduced switching frequency compared with the existing ZSC suppression methods. Simulation and experimental results are demonstrated for confirming the proposed TV-MPCC.
4 November 2022 in IEEE Transactions on Power Electronics
This paper proposes a current deadbeat-based fault-tolerant control scheme for a dual three-phase permanent magnet synchronous generator with a high-resistance connection (HRC) fault. Firstly, the voltage deviation caused by the HRC fault is deduced, and the postfault prediction model is established. Then, the instantaneous active power and reactive power are analyzed considering the negative-sequence voltage and current. To eliminate the fluctuation components and improve the steady-state performance, the fault-tolerant current references are designed under the condition of HRC fault. The deadbeat principle is employed to track the periodic dq current references accurately. The two targets of eliminating output power fluctuations and stabilizing electromagnetic torque are achieved. Finally, the virtual voltage vectors are synthesized to generate the reference voltage and suppress the harmonic current. The proposed method effectively restrains the fluctuations of active power, reactive power, dc-link voltage, and electromagnetic torque. The experimental results verify the effectiveness of the proposed method.