The ability to manipulate and focus particles within microscale fluidic environments is crucial to advancing biological, chemical, and medical research. Precise and high-throughput particle focusing is an essential prerequisite for various applications, including cell counting, biomolecular detection, sample sorting, and enhancement of biosensor functionalities. Active and sheath-assisted focusing techniques offer accuracy but necessitate the introduction of external energy fields or additional sheath flows. In contrast, passive focusing methods exploit the inherent fluid dynamics in achieving high-throughput focusing without external actuation. This review analyzes the latest developments in strategies of sheathless inertial focusing, emphasizing inertial and elasto-inertial microfluidic focusing techniques from the channel structure classifications. These methodologies will serve as pivotal benchmarks for the broader application of microfluidic focusing technologies in biological sample manipulation. Then, prospects for future development are also predicted. This paper will assist in the understanding of the design of microfluidic particle focusing devices.
The high-precision and high-purity isolation of circulating tumor cells (CTCs) from whole blood is vital to early cancer detection. Cascaded microfluidic separation is highly efficient because it connects multiple-stage separations in series. Here, we numerically investigated sheathless tumor cell separation with size-dependent cascaded inertial and deterministic lateral displacement (DLD) microfluidic device. The inertial microfluidic is arranged in the first-stage unit for particle focusing and rough sorting, and the cascaded DLD microfluidic is arranged in the second stage for realizing further sorting and purification. A parametric study with flow rate range from 100–600 μl/min and aspect ratio range from 60:100 to 60:300 of the first stage was carried out to optimize channel structure for realizing high-efficiency separation. Then, the pre-separation mechanism within the spiral microchannel was analyzed. The purity of the obtained CTCs and the separation efficiency were further improved using a droplet-type microcolumn DLD microfluidic device as the second unit. The cascade eliminates the need for additional force fields and reduces device complexity while simplifying operation and reducing the chance of sample contamination.
In situ stress measurements have been widely used in various deposition processes for stress detection. The substrate size can affect the uniformity of curvature across the entire surface, which is a major cause of incorrect stress measurements. However, because of the inherent concept of measurement theory and the complexities of the influence of substrate size on measurement accuracy, the underlying nonlinear effects of the rectangular substrate are still not fully understood. We discovered that increasing the substrate size caused an increase in nonlinear effect (nonuniform distribution of curvature radii and stresses in the x and y directions) and surface defects on the rectangular substrate using in situ stress measurement. Furthermore, the bending stiffness of the substrate, which was influenced by the substrate size, was established to illustrate the effect of substrate size on the nonlinear effect. The total stress of the deposit was concentrated at the edge in both the x and y directions, and the deposit at the edge was prone to delamination and cracking. When the substrate size was reduced, the deposit surface did not show obvious defects, and the stress errors in the x and y directions were only 2.34% and 2.54%, respectively. These findings will be beneficial to improve the accuracy of in situ stress measurement and further understand the causes of nonlinear effects.