The ability to manipulate and focus particles within microscale fluidic environments is crucial to advancing biological, chemical, and medical research. Precise and high-throughput particle focusing is an essential prerequisite for various applications, including cell counting, biomolecular detection, sample sorting, and enhancement of biosensor functionalities. Active and sheath-assisted focusing techniques offer accuracy but necessitate the introduction of external energy fields or additional sheath flows. In contrast, passive focusing methods exploit the inherent fluid dynamics in achieving high-throughput focusing without external actuation. This review analyzes the latest developments in strategies of sheathless inertial focusing, emphasizing inertial and elasto-inertial microfluidic focusing techniques from the channel structure classifications. These methodologies will serve as pivotal benchmarks for the broader application of microfluidic focusing technologies in biological sample manipulation. Then, prospects for future development are also predicted. This paper will assist in the understanding of the design of microfluidic particle focusing devices.
High-precision and high-purity acquisition of tumor cells from whole blood is vital for early disease detection and diagnosis. Here, we investigated a cascaded inertial and acoustic microfluidic device for sheathless and label-free separation of circulating tumor cells (CTCs) from the blood through numerical methods. We introduced a spiral microfluidics channel in the first stage (1st) for cell focusing and rough sorting to improve chip integration and reduce the dependence on sheath flow and extra syringe pumps. In the 1st, we simulated the spiral microfluidic with a rectangular cross section to determine the key parameters affecting the migration kinetics of blood cells and tumor cells. Under the influence of Dean drag force and inertial lift force, blood cells migrate toward the inner side of the channel, while CTCs flow out close to the outer side. A flow rate of 400 μl/min was optimized for the operating flow rate. To improve and further enhance the 1st sorting efficiency and purity, we introduced tilted angle standing surface acoustic wave (SSAW) in the second stage (2st). Based on the parametric study, the SSAW with 33.3 MHz, tilted angle with 5°, and acoustic pressure amplitude with 0.7 MPa was selected as the operating parameter. The product of the 1st is used as input for the 2st acoustofluidic unit, enabling a more accurate separation process to obtain CTCs. The simulation results show that the inertial microfluidic units arranged in the first stage help to improve throughput and assist in 2st acoustofluidic separation, and the cascaded chip has accomplished a separation performance of nearly 100% in terms of purity and efficiency.
A fast mixing is critical for subsequent practical development of microfluidic devices, which are often used for assays in the detection of reagents and samples. The present work sets up computational fluid dynamics simulations to explore the flow characteristic and mixing mechanism of fluids in cross-shaped mixers within the laminar regime. First, the effects of increasing an operating parameter on local mixing quality along the microchannels are investigated. It is found that sufficient diffusion cannot occur even though the concentration gradient is large at a high Reynolds number. Meanwhile, a method for calculating local mixing efficiency is also characterized. The mixing efficiency varies exponentially with the flow distance. Second, in order to optimize the cross-shaped mixer, the effects of design parameters, namely aspect ratio, mixing angle and blockage, on mixing quality are captured and the visualization of velocity and concentration distribution are demonstrated. The results show that the aspect ratio and the blockage play an important role in accelerating the mixing process. They can improve the mixing efficiency by increasing the mass transfer area and enhancing the chaotic advection, respectively. In contrast, the inflow angle that affects dispersion length is not an effective parameter. Besides, the surface roughness, which makes the disturbance of fluid flow by roughness more obvious, is considered. Three types of rough elements bring benefits for enhancing mixing quality due to the convection induced by the lateral velocity.
Water environments contaminated by heavy metal ions present significant challenges because these pollutants do not degrade naturally, leading to their gradual bioaccumulation in animals and plants, which ultimately poses an insurmountable threat to human health. Therefore, rapid and accurate detection of heavy metal ions in water is of great significance for environmental protection and disease prevention. In this work, we developed a novel method based on microfluidic electrophoresis coupled with indirect chemiluminescence for the immediate detection of Cd(II), Pb(II) and Hg(II) heavy metal ions. The displacement of the Co(II) ions within the chemiluminescence mixture by the above migrating sample cations caused a measurable reduction in the background signal. The results showed that the detection limits of Cd(II), Pb(II) and Hg(II) ions under the best detection conditions were 5.83 × 10−8 M, 5.38 × 10−8 M and 2.09 × 10−8 M, respectively, which were 1–2 orders of magnitude lower than those of the indirect UV method and 1 order of magnitude lower than that of the indirect laser induced detection method. This method can provide a possibility for the rapid detection of multiple heavy metal ions in actual water environments.
Micromixers are crucial for rapid and homogeneous mixing in lab-on-a-chip systems. This study presents a novel passive micromixer that synergistically combines a Zigzag channel with D-shaped obstacles to enhance mixing across a broad Reynolds number (Re) range of 0.1–50. The design leverages flow splitting, recombination, and the generation of localized high-velocity streams to effectively disrupt laminar flow. A comprehensive parametric study optimized key geometric parameters, including obstacle dimensions (b2, a2) and the number of mixing units (n). Results show that optimizing b2 to 500 μm and increasing a2 to 250 μm significantly enhances mixing efficiency. Mechanistic analysis reveals that centrifugal forces in the Zigzag channel work synergistically with obstacle-induced perturbations to stretch and fold the fluid interface, promoting transverse transport. The optimized mixer, fabricated and experimentally validated, achieves a high mixing index (>0.85) under all Re conditions. This work provides valuable design insights for developing efficient, compact micromixers for micro-total analysis systems.
The development of high-performance optical fiber sensors based on surface plasmon resonance (SPR) represents a significant advancement in precision detection technology, particularly for biomedical and environmental monitoring applications requiring real-time response and minimal sample consumption. This research conducts a systematic numerical investigation of a D-shaped fiber SPR sensor incorporating an optimized silver-hematite (Ag-α-Fe2O3) composite grating structure. Through comprehensive finite element simulations and parameter analysis, we demonstrate that controlling the silver layer thickness at 45 nm while maintaining the α-Fe2O3 thickness at 12 nm achieves optimal electric field confinement. The grating gap width optimization at 30 nm enables maximum sensitivity through enhanced localized surface plasmon resonance effects, while the residual cladding thickness of 0.5 μm provides the ideal balance between detection accuracy and sensitivity. The research establishes fundamental design principles for high-performance SPR sensors by elucidating the critical relationships between geometric parameters and sensing characteristics, providing valuable insights for developing next-generation sensors with enhanced performance for advanced sensing applications in environmental monitoring and medical diagnostics.