Ostextubation stridor or subglottic stenosis. Unfortunately, selecting endotracheal tube size based on height, weight, or age does not reliably lead to the proper tube. The knowledge of airway diameter, especially using a bedside noninvasive tool, could therefore be helpful in anesthesia and intensive care. METHODS: We studied 19 healthy volunteers (27 ± 3 yr, nine females) to compare the transverse diameter of the cricoid lumen assessed by ultrasonography and magnetic resonance imaging. RESULTS: We found a strong correlation between the two techniques (r = 0.99, P < 0.05) confirmed by Bland–Altman analysis with a bias of 0.14 mm, a precision of 0.33 mm, and limits of agreement of −0.68 mm/0.96 mm. CONCLUSION: In young healthy adults, ultrasonography appeared to be a reliable tool to assess the diameter of the subglottic upper airway....
14 September 2015 in British Journal of Anaesthesia
Since arrhythmia induces irregular pulse waves, it is widely considered to cause flawed oscillometric brachial cuff measurements of blood pressure (BP). However, strong data are lacking. We assessed whether the agreement of oscillometric measurements with intra-arterial measurements is worse during arrhythmia than during regular rhythm. Among patients of three intensive care units (ICUs), a prospective comparison of three pairs of intra-arterial and oscillometric BP readings was performed among patients with arrhythmia and an arterial line already present. After each inclusion in the arrhythmia group, one patient with regular rhythm was included as a control. International Organization for Standardization (ISO) standard validation required a mean bias <5 (sd 8) mm Hg. In 135 patients with arrhythmia, the agreement between oscillometric and intra-arterial measurements of systolic, diastolic and mean BP was similar to that observed in 136 patients with regular rhythm: for mean BP, similar mean bias [−0.1 (sd 5.2) and 1.9 (sd 5.9) mm Hg]. In both groups, the ISO standard was satisfied for mean and diastolic BP, but not for systolic BP (sd >10 mm Hg) in our ICU population. The ability of oscillometry to detect hypotension (systolic BP <90 mm Hg or mean BP 10% increase in mean BP after cardiovascular intervention) and hypertension (systolic BP >140 mm Hg) was good and similar during arrhythmia and regular rhythm (respective areas under the receiver operating characteristic curves ranging from 0.89 to 0.96, arrhythmia vs regular rhythm between-group comparisons all associated with P>0.3). Contrary to widespread belief, arrhythmia did not cause flawed automated brachial cuff measurements.
Introduction: Pulse pressure variation (PPV) has been shown to predict fluid responsiveness in ventilated intensive care unit (ICU) patients. The present study was aimed at assessing the diagnostic accuracy of PPV for prediction of fluid responsiveness by using the grey zone approach in a large population. Methods: The study pooled data of 556 patients from nine French ICUs. Hemodynamic (PPV, central venous pressure (CVP) and cardiac output) and ventilator variables were recorded. Responders were defined as patients increasing their stroke volume more than or equal to 15% after fluid challenge. The receiver operating characteristic (ROC) curve and grey zone were defined for PPV. The grey zone was evaluated according to the risk of fluid infusion in hypoxemic patients. Results: Fluid challenge led to increased stroke volume more than or equal to 15% in 267 patients (48%). The areas under the ROC curve of PPV and CVP were 0.73 (95% confidence interval (CI): 0.68 to 0.77) and 0.64 (95% CI 0.59 to 0.70), respectively (P <0.001). A grey zone of 4 to 17% (62% of patients) was found for PPV. A tidal volume more than or equal to 8 ml.kg-1 and a driving pressure (plateau pressure - PEEP) more than 20 cmH2O significantly improved the area under the ROC curve for PPV. When taking into account the risk of fluid infusion, the grey zone for PPV was 2 to 13%. Conclusions: In ventilated ICU patients, PPV values between 4 and 17%, encountered in 62% patients exhibiting validity prerequisites, did not predict fluid responsiveness.
Introduction: Fluid responsiveness prediction is of utmost interest during acute respiratory distress syndrome (ARDS), but the performance of respiratory pulse pressure variation (ΔRESPPP) has scarcely been reported. In patients with ARDS, the pathophysiology of ΔRESPPP may differ from that of healthy lungs because of low tidal volume (Vt), high respiratory rate, decreased lung and sometimes chest wall compliance, which increase alveolar and/or pleural pressure. We aimed to assess ΔRESPPP in a large ARDS population. Methods: Our study population of nonarrhythmic ARDS patients without inspiratory effort were considered responders if their cardiac output increased by >10% after 500-ml volume expansion. Results: Among the 65 included patients (26 responders), the area under the receiver-operating curve (AUC) for ΔRESPPP was 0.75 (95% confidence interval (CI95): 0.62 to 0.85), and a best cutoff of 5% yielded positive and negative likelihood ratios of 4.8 (CI95: 3.6 to 6.2) and 0.32 (CI95: 0.1 to 0.8), respectively. Adjusting ΔRESPPP for Vt, airway driving pressure or respiratory variations in pulmonary artery occlusion pressure (ΔPAOP), a surrogate for pleural pressure variations, in 33 Swan-Ganz catheter carriers did not markedly improve its predictive performance. In patients with ΔPAOP above its median value (4 mmHg), AUC for ΔRESPPP was 1 (CI95: 0.73 to 1) as compared with 0.79 (CI95: 0.52 to 0.94) otherwise (P = 0.07). A 300-ml volume expansion induced a ≥2 mmHg increase of central venous pressure, suggesting a change in cardiac preload, in 40 patients, but none of the 28 of 40 nonresponders responded to an additional 200-ml volume expansion. Conclusions: During protective mechanical ventilation for early ARDS, partly because of insufficient changes in pleural pressure, ΔRESPPP performance was poor. Careful fluid challenges may be a safe alternative.