Dongyang Ou

Dr. Dongyang Ou


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 October 2021 in Land
Verified
Journal Article
Open access
PDF file
YZYinghui Zhao
Yinghui Zhao
RARu An
Ru An
Neal XiongNeal Xiong
Neal Xiong
DODongyang Ou
Dongyang Ou
CJCongfeng JIANG
Congfeng JIANG
Land-use classification is fundamental for environmental and water resource evaluation in coastal plain areas. However, comprehensive remote sensing image-based land-use analysis is challenged by the lack of massive remote sensing images and the massive computing power of large-scale server systems. In this paper, the spatial-temporal land-use change characteristics of the Hangzhou Bay area coastal plain are investigated on the Google Earth Engine platform. The proposed model uses a random forest algorithm to assist the land-use classification. The dataset is selected from the year 2009 to 2020 and classified with an average classification accuracy of 89% and Kappa coefficient of 88%. The results show that the land use in the selected region is affected by urbanization, the balance of cultivated land occupation and compensation, construction of economic development zone, and other activities. The investigation also shows that in the past 12 years, land use has changed rapidly, and each land-use type maintains the dynamic balance of occupation and compensation. Although the overall land-use distribution is stable, the information entropy fluctuates at a high level, with an average value of 1.15, and the multi-year average value of equilibrium is as high as 0.83. The driving force of land-use change is analyzed and accounted as demographics and human population dynamics, social-economic development, urbanization, and coupling effects of the above-mentioned factors.

13 May 2022 in Security and Communication Networks
Verified
Journal Article
Open access
PDF file
YXYang Xu
Yang Xu
JZJilin Zhang
Jilin Zhang
YRYongjian Ren
Yongjian Ren
YZYan Zeng
Yan Zeng
JYJunfeng Yuan
Junfeng Yuan
DODongyang Ou
Dongyang Ou
An intelligent maritime navigation system is expected to play an important role in the realm of Internet of Vessels (IoV). As a key technology in navigation systems, vessel trajectory prediction technology is critical to the IoV. Automatic identification system (AIS), an automated tracking system, is used extensively for vessel trajectory prediction. However, certain characteristics in the AIS data, such as the large number of anchored trajectories in the area, anomalous sharp turns of some trajectories, and the behavioral differences of vessels in different segments, limit the prediction accuracy. In this study, we propose a novel vessel trajectory prediction model for accurate prediction with the following characteristics: (1) an anchor trajectory elimination algorithm to eliminate anchor trajectories; (2) a statistical trajectory restoration algorithm to repair sharp turning; (3) a two-stage clustering algorithm (D-KMEANS) to distinguish vessel behavior; and (4) a deep bidirectional gate recurrent unit (Stacked-BiGRUs) model to predict vessel trajectory and compare the accuracy of the model before and after improvement. The results show that the mean square error and the mean absolute error of the improved model are reduced by 27% and 46%, respectively. This research shows good potential for maritime navigation early warning and safety.

1 June 2017
Verified
Conference Paper
Closed access
CJCongfeng JIANG
Congfeng JIANG
YWYumei Wang
Yumei Wang
DODongyang Ou
Dongyang Ou
BLBing Luo
Bing Luo
WSWeisong Shi
Weisong Shi
The huge energy consumption in data centers produces not only high electricity bill but also tremendous carbon footprints. Although today's servers and data centers of leading internet companies are more energy efficient than ever before, the fluctuations in external workload and internal resource utilization calls for energy proportional computing. Insight into server energy proportionality can help improve workload placement while also reducing energy consumption. In this paper, we investigate all 477 valid published results of SPECpower_ssj benchmark from 2007 to 2016Q3 and reorganize them by hardware availability year for more accurate analysis on production servers. Through comprehensive analysis we find that: (1) The specious stagnation of energy proportionality in recent years is mainly caused by the adoption of processors of specific microarchitecture and is not the indicative trend of energy proportionality improvement. (2) Microarchitecture evolution has more influence on energy efficiency improvement than energy proportionality. (3) Today's servers' peak energy efficiencies are shifting from 100% resource utilization to 80% or 70% utilization and server energy proportionality improves with such shifting. We then conduct extensive experiments on 4 rack servers to investigate the energy efficiency variations under different hardware configurations, including memory per core installation and processor frequency scaling. Our experiments show that hardware configuration has significant impact on server's energy efficiency. Our findings presented in this paper provide useful insights and guidance to system designers, as well as data center operators for energy proportionality aware workload placement and energy savings.

6 July 2021 in Energies
Verified
Journal Article
Open access
PDF file
KZKai qiang Zhang
Kai qiang Zhang
DODongyang Ou
Dongyang Ou
CJCongfeng JIANG
Congfeng JIANG
YQYeliang Qiu
Yeliang Qiu
LYLongchuan Yan
Longchuan Yan
In terms of power and energy consumption, DRAMs play a key role in a modern server system as well as processors. Although power-aware scheduling is based on the proportion of energy between DRAM and other components, when running memory-intensive applications, the energy consumption of the whole server system will be significantly affected by the non-energy proportion of DRAM. Furthermore, modern servers usually use NUMA architecture to replace the original SMP architecture to increase its memory bandwidth. It is of great significance to study the energy efficiency of these two different memory architectures. Therefore, in order to explore the power consumption characteristics of servers under memory-intensive workload, this paper evaluates the power consumption and performance of memory-intensive applications in different generations of real rack servers. Through analysis, we find that: (1) Workload intensity and concurrent execution threads affects server power consumption, but a fully utilized memory system may not necessarily bring good energy efficiency indicators. (2) Even if the memory system is not fully utilized, the memory capacity of each processor core has a significant impact on application performance and server power consumption. (3) When running memory-intensive applications, memory utilization is not always a good indicator of server power consumption. (4) The reasonable use of the NUMA architecture will improve the memory energy efficiency significantly. The experimental results show that reasonable use of NUMA architecture can improve memory efficiency by 16% compared with SMP architecture, while unreasonable use of NUMA architecture reduces memory efficiency by 13%. The findings we present in this paper provide useful insights and guidance for system designers and data center operators to help them in energy-efficiency-aware job scheduling and energy conservation.

14 February 2022 in Computing
Verified
Journal Article
Closed access
PDF file
YLYuegang Li
Yuegang Li
DODongyang Ou
Dongyang Ou
XZXin Zhou
Xin Zhou
CJCongfeng JIANG
Congfeng JIANG
CCCHRISTOPHE CERIN
CHRISTOPHE CERIN

1 December 2022
Verified
Book Chapter
Closed access
PDF file
TZTing Zhang
Ting Zhang
DODongyang Ou
Dongyang Ou
ZGZhefeng Ge
Zhefeng Ge
CJCongfeng JIANG
Congfeng JIANG
CCCHRISTOPHE CERIN
CHRISTOPHE CERIN
LYLongchuan Yan
Longchuan Yan