Ljubiša Ristic

Prof. Dr. Ljubiša Ristic

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 April 2017 in Journal of Prosthodontics
Verified
Journal Article
Closed access
PDF file
LRLjubiša Ristic
Ljubiša Ristic
DDDragana Dakovic
Dragana Dakovic
SPSrdjan D. Dušan Poštić
Srdjan D. Dušan Poštić
ZLZoran Lazic
Zoran Lazic
MBMiljana Bacevic
Miljana Bacevic
DVDragana Vucevic
Dragana Vucevic

29 September 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
SPSrdjan D. Dušan Poštić
Srdjan D. Dušan Poštić
LTLjiljana Tihacek-Sojic
Ljiljana Tihacek-Sojic
SDSlobodan Dodic
Slobodan Dodic
ITIvan Tanasic
Ivan Tanasic
MMMilos Milosevic
Milos Milosevic
PSPredrag Sojic
Predrag Sojic
Statement of problem: The stereo-optical method can be used for assessment of strains and deformations of different fixed or removable prosthodontic constructions. Material and methods: The study used two master casts of a lower jaw with bilateral terminal edentulous seats. Their topography was identical, with missing lower molars, the left lower second premolar, and the right canine and incisors, indicating a partially edentulous lower jaw according to Eichner's B3 (and C2) classification (i.e. Kennedy class 1). The control cast had conventional oval copings for overdenture. The experimental cast was almost the same as the control, with the exception of the surfaces simulating three specific milled copings covering the remaining tooth substance. Controlled loading was measured using a gnathodynamometer. Loading stages were at 400, 800, and 1000 N. Measurements of strain and displacement were provided by the Digital Image Correlation Method and the associated software. ‘Wilcoxon Lambda’ two sample tests based on the simple linear rank statistics were used in the analysis of differences in the displacement and deformation between the control rounded and experimental milled copings under loading numerical values. Results: It was found that smaller values of deformations are measured on milled copings when compared to the controls. There were statistically significant differences in displacement between the control rounded and experimental milled copings (Pr > |Z| = 0.001) as well as in deformations (Pr > |Z| = 0.0298). Conclusions: Experimental milled copings are less susceptible to deformation compared to the control conventional oval copings. These findings may have clinical significance in improvements of primary and secondary retention of overdentures on milled copings.