Jordi Abella

Dr. Jordi Abella


Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2017 in Sensors
Verified
Journal Article
Open access
PDF file
MAMargalida Artigues-Cladera
Margalida Artigues-Cladera
JAJordi Abella
Jordi Abella
SCSergi Colominas
Sergi Colominas
Amperometric biosensors based on the use of glucose oxidase (GOx) are able to combine the robustness of electrochemical techniques with the specificity of biological recognition processes. However, very little information can be found in literature about the fundamental analytical parameters of these sensors. In this work, the analytical behavior of an amperometric biosensor based on the immobilization of GOx using a hydrogel (Chitosan) onto highly ordered titanium dioxide nanotube arrays (TiO2NTAs) has been evaluated. The GOx–Chitosan/TiO2NTAs biosensor showed a sensitivity of 5.46 μA·mM−1 with a linear range from 0.3 to 1.5 mM; its fundamental analytical parameters were studied using a commercial soft drink. The obtained results proved sufficient repeatability (RSD = 1.9%), reproducibility (RSD = 2.5%), accuracy (95–105% recovery), and robustness (RSD = 3.3%). Furthermore, no significant interferences from fructose, ascorbic acid and citric acid were obtained. In addition, the storage stability was further examined, after 30 days, the GOx–Chitosan/TiO2NTAs biosensor retained 85% of its initial current response. Finally, the glucose content of different food samples was measured using the biosensor and compared with the respective HPLC value. In the worst scenario, a deviation smaller than 10% was obtained among the 20 samples evaluated.

1 August 2011 in Journal of Nuclear Materials
Verified
Journal Article
Closed access
CSCarsten Schroer
Carsten Schroer
JKJuergen Konys
Juergen Konys
AVAriadna Verdaguer
Ariadna Verdaguer
JAJordi Abella
Jordi Abella
AGAlessandro Gessi
Alessandro Gessi
JCJean-Louis Courouau
Jean-Louis Courouau

17 June 2016 in Materials
Verified
Journal Article
Open access
PDF file
LRLourdes Recha-Sancho
Lourdes Recha-Sancho
FMFranklin T. Moutos
Franklin T. Moutos
JAJordi Abella
Jordi Abella
Farshid GuilakFarshid Guilak
Farshid Guilak
Carlos E. SeminoCarlos E. Semino
Carlos E. Semino
Adult articular cartilage has a limited capacity for growth and regeneration and, with injury, new cellular or biomaterial-based therapeutic platforms are required to promote repair. Tissue engineering aims to produce cartilage-like tissues that recreate the complex mechanical and biological properties found in vivo. In this study, a unique composite scaffold was developed by infiltrating a three-dimensional (3D) woven microfiber poly (ε-caprolactone) (PCL) scaffold with the RAD16-I self-assembling nanofibers to obtain multi-scale functional and biomimetic tissue-engineered constructs. The scaffold was seeded with expanded dedifferentiated human articular chondrocytes and cultured for four weeks in control and chondrogenic growth conditions. The composite constructs were compared to control constructs obtained by culturing cells with 3D woven PCL scaffolds or RAD16-I independently. High viability and homogeneous cell distribution were observed in all three scaffolds used during the term of the culture. Moreover, gene and protein expression profiles revealed that chondrogenic markers were favored in the presence of RAD16-I peptide (PCL/RAD composite or alone) under chondrogenic induction conditions. Further, constructs displayed positive staining for toluidine blue, indicating the presence of synthesized proteoglycans. Finally, mechanical testing showed that constructs containing the PCL scaffold maintained the initial shape and viscoelastic behavior throughout the culture period, while constructs with RAD16-I scaffold alone contracted during culture time into a stiffer and compacted structure. Altogether, these results suggest that this new composite scaffold provides important mechanical requirements for a cartilage replacement, while providing a biomimetic microenvironment to re-establish the chondrogenic phenotype of human expanded articular chondrocytes.

1 January 2002 in Corrosion Science
Verified
Journal Article
Closed access
JAJordi Abella
Jordi Abella
IBIouri Balachov
Iouri Balachov
DMDigby D Macdonald
Digby D Macdonald
PMPeter J Millet
Peter J Millet

1 October 2014 in Fusion Engineering and Design
Verified
Journal Article
Closed access
NONerea Ordas
Nerea Ordas
ABA. Bereciartu
A. Bereciartu
CGC. García-Rosales
C. García-Rosales
AMA. Moroño
A. Moroño
MMM. Malo
M. Malo
LSL. Sedano
L. Sedano

18 June 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MAMargalida Artigues-Cladera
Margalida Artigues-Cladera
JGJoan Gilabert-Porres
Joan Gilabert-Porres
RBRobert Texido Bartes
Robert Texido Bartes
SBSalvador Borros
Salvador Borros
JAJordi Abella
Jordi Abella
SCSergi Colominas
Sergi Colominas
Bioanalytical methods, in particular electrochemical biosensors, are increasingly used in different industrial sectors due to their simplicity, low cost, and fast response. However, to be able to reliably use this type of device, it is necessary to undertake in-depth evaluation of their fundamental analytical parameters. In this work, analytical parameters of an amperometric biosensor based on covalent immobilization of glucose oxidase (GOx) were evaluated. GOx was immobilized using plasma-grafted pentafluorophenyl methacrylate (pgPFM) as an anchor onto a tailored HEMA-co-EGDA hydrogel that coats a titanium dioxide nanotubes array (TiO2NTAs). Finally, chitosan was used to protect the enzyme molecules. The biosensor offered outstanding analytical parameters: repeatability (RSD = 1.7%), reproducibility (RSD = 1.3%), accuracy (deviation = 4.8%), and robustness (RSD = 2.4%). In addition, the Ti/TiO2NTAs/ppHEMA-co-EGDA/pgPFM/GOx/Chitosan biosensor showed good long-term stability; after 20 days, it retained 89% of its initial sensitivity. Finally, glucose concentrations of different food samples were measured and compared using an official standard method (HPLC). Deviation was lower than 10% in all measured samples. Therefore, the developed biosensor can be considered to be a reliable analytical tool for quantification measurements.