Joan Gilabert-Porres

Dr. Joan Gilabert-Porres

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2015 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
JGJoan Gilabert-Porres
Joan Gilabert-Porres
SMSara Marti
Sara Marti
LCLaura Calatayud
Laura Calatayud
VRVictor Ramos
Victor Ramos
ARAntoni Rosell
Antoni Rosell
SBSalvador Borrós
Salvador Borrós

18 June 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MAMargalida Artigues-Cladera
Margalida Artigues-Cladera
JGJoan Gilabert-Porres
Joan Gilabert-Porres
RBRobert Texido Bartes
Robert Texido Bartes
SBSalvador Borros
Salvador Borros
JAJordi Abella
Jordi Abella
SCSergi Colominas
Sergi Colominas
Bioanalytical methods, in particular electrochemical biosensors, are increasingly used in different industrial sectors due to their simplicity, low cost, and fast response. However, to be able to reliably use this type of device, it is necessary to undertake in-depth evaluation of their fundamental analytical parameters. In this work, analytical parameters of an amperometric biosensor based on covalent immobilization of glucose oxidase (GOx) were evaluated. GOx was immobilized using plasma-grafted pentafluorophenyl methacrylate (pgPFM) as an anchor onto a tailored HEMA-co-EGDA hydrogel that coats a titanium dioxide nanotubes array (TiO2NTAs). Finally, chitosan was used to protect the enzyme molecules. The biosensor offered outstanding analytical parameters: repeatability (RSD = 1.7%), reproducibility (RSD = 1.3%), accuracy (deviation = 4.8%), and robustness (RSD = 2.4%). In addition, the Ti/TiO2NTAs/ppHEMA-co-EGDA/pgPFM/GOx/Chitosan biosensor showed good long-term stability; after 20 days, it retained 89% of its initial sensitivity. Finally, glucose concentrations of different food samples were measured and compared using an official standard method (HPLC). Deviation was lower than 10% in all measured samples. Therefore, the developed biosensor can be considered to be a reliable analytical tool for quantification measurements.

8 April 2020 in ACS Applied Bio Materials
Verified
Journal Article
Closed access
CGCristina García-Bonillo
Cristina García-Bonillo
RBRobert Texido Bartes
Robert Texido Bartes
GRGuillermo Reyes-Carmenaty
Guillermo Reyes-Carmenaty
JGJoan Gilabert-Porres
Joan Gilabert-Porres
SBSalvador Borros
Salvador Borros

1 October 2022 in Heliyon
Verified
Journal Article
Open access
CGCristina García-Bonillo
Cristina García-Bonillo
RTRobert Texidó
Robert Texidó
JGJoan Gilabert-Porres
Joan Gilabert-Porres
SBSalvador Borrós
Salvador Borrós
Biofilm formation in medical devices represents one of the major problems for the healthcare system, especially those that occur on implantable silicone-based devices. To provide a general solution to avoid biofilm formation in the first stages of development, this work studied how nanostructured metallic silver coatings hinder bacteria-surface interaction by preventing bacteria adhesion. The three studied silver nanostructures ("Sharp blades", "Thick blades" and "Leaves") combined superhydrophobic behavior with a physical impediment of the coating nanostructure that produced a bacteriophobic effect avoiding the adhesion mechanism of different bacterial strains. These silver nanostructures are immobilized on stretchable substrates through a polymeric thin film of plasma-polymerized penta-fluorophenyl methacrylate. The control over the nanostructures and therefore its bacteriophobic-bactericidal effect depends on the plasma polymerization conditions of the polymer. The characterization of this bacteriophobic effect through FE-SEM microscopy, live/dead cell staining, and direct bacterial adhesion counts, provided a complete mapping of how bacteria interact with the surface in each scenario. Results revealed that the bacterial adhesion was reduced by up to six orders of magnitude in comparison with uncoated surfaces thereby constituting an effective strategy to avoid the formation of biofilm on medical materials.

9 November 2022 in Advanced Electronic Materials
Verified
Journal Article
Open access
RBRobert Texido Bartes
Robert Texido Bartes
GNGloria Nieva‐Esteve
Gloria Nieva‐Esteve
JGJoan Gilabert-Porres
Joan Gilabert-Porres
GRGuillermo Reyes
Guillermo Reyes
SBSalvador Borros
Salvador Borros
Strain sensors for wearable electronic devices have received attention due to their potential application in medicine for physiological monitoring or as part of advanced prosthetics. However, low sensitivity values as well as complex fabrication procedures remain significant challenges limiting the applicability. This work presents the fabrication of a strain sensor based on the separation of silver microplates immobilized on a stretchable substrate. The deposition of the microplates is achieved through the exposition of a glucosamine‐functionalized surface to the Tollens’ reagent, being a versatile fabrication methodology able to be implemented in a wide range of substrates. The obtained sensors present a high stretchability (>100%), high conductivity (105 S m–1), good linearity (R2 > 0.98 under 30% strain), good hysteresis properties, and high sensitivity (up to GF = 900 000). Hence, the sensors allow the measurement of very small deformations even in dynamic range, where it presents a stable linear response for the quantification of cyclic deformations of 0.02% strain. Moreover, the applicability of these sensors has been studied in motion‐sensing devices and in a pressure sensor revealing that this technology may expand the potential applications of wearable electronic devices.

1 September 2019 in Colloids and Surfaces B: Biointerfaces
Verified
Journal Article
Closed access
AMAnna Mas-Vinyals
Anna Mas-Vinyals
JGJoan Gilabert-Porres
Joan Gilabert-Porres
LFLaura Figueras-Esteve
Laura Figueras-Esteve
SBSalvador Borros
Salvador Borros