For decades, sensorless position estimation methods gained lots of interest from the research community, especially in the field of electric drives and active magnetic bearings (AMBs). In particular, the direct flux control (DFC) technique promises unique advantages over other sensorless techniques, such as a higher bandwidth, but on the other hand, it requires the coils to be connected in a star topology. Until now, star-point connections are rarely found on active magnetic bearings. In consequence, there is no known publication about the application of the DFC to an AMB to this date. In order to apply the DFC to an AMB, a star-point driving approach for AMBs must be developed beforehand. A star-connected driving approach, capable of driving a four-phase AMB, is proposed and validated against traditional H-bridges in a simulation. Further, the strategy is tested in a physical application and generalised for 4 phases. In terms of current dynamics, the simulation results can be compared to the well-known full H-bridge driving. The experiments on the physical application show that the actual current in the coils follows a reference with satisfactory accuracy. Moreover, the inductance measurements of the coils show a strong dependency on the rotor’s position, which is crucial for sensorless operation. A star-point connection delivers a satisfying response behaviour in an AMB application, which makes sensorless techniques that require a star point, such as the DFC, applicable to active magnetic bearings.
Due to their unique properties, like no mechanical contact and therefore no wear and no lubrication needed, Active Magnetic Bearings (AMBs) have been a dynamic field of research in the past decades. The high non-linearities of AMBs generate many challenges for the control of the otherwise unstable system, thus they need to be addressed to deliver the performance that modern applications require. Integrating the current controller dynamics into the model of a position controller in a cascading control loop helps to improve the performance of the control loop compared to a plain current controlled schema. Further, this nested control loop guarantees the predefined current dynamics of the current controller, tuned according to an industrial criterion. The systems dynamics are modelled and the proposed controller is validated experimentally on a physical test bench. The experimental results show a performant position control with a nested and explicit current controller on an AMB, even with a large air gap and star-connected coils. The trajectory range of the rotor was reduced by 87% to ±20 m, compared to a plain current-controlled model. The proposed control strategy lays the foundation for further research, especially concerning sensorless position estimation techniques since these usually have limited bandwidth and benefit from a predefined current dynamic.
Methods for self-sensing position determination in active magnetic bearings enable a reduction in system costs and complexity. Many well-known methods rely on current measurements or their derivatives to estimate the rotor’s displacement relative to the centre. However, measuring voltage often yields a better signal-to-noise ratio compared to current measurements, especially considering smaller machines where the current is often sensed using a shunt. Nevertheless, star-connected active magnetic bearings and the associated star-point voltage are rarely addressed in research. The star-point voltage provides valuable information for self-sensing position determination in other types of electric machines, such as permanent magnet synchronous motors. The goal of this research is to exploit the star-point voltage of an active magnetic bearing to estimate the rotor position. This study presents an analytical derivation of the star-point voltage for a four-phase active magnetic bearing, followed by a description of a differential measurement method for the star-point voltage. It is shown that, under the selected operating conditions, the resulting measured values depend exclusively on the coil inductance and the known DC supply voltage. To extract the position information from the obtained signal, the system was characterized at a standstill. The resulting measured values were used for polynomial fits, which were implemented on the microcontroller. Finally, the proposed method was experimentally validated inside the control loop under quasi static conditions. Experiments conducted on a laboratory prototype with a large air gap of 2 mm showed an RMS value of the estimation error ranging from 9.2 μm to 36.9 μm and a signal-to-noise ratio of approximately 70 dB.